Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth

被引:78
作者
Saber, S. E. D. M. [1 ]
Nagy, M. M. [1 ]
Schaefer, E. [2 ]
机构
[1] Ain Shams Univ, Fac Dent, Dept Endodont, Cairo 11841, Egypt
[2] Univ Munster, Sch Dent, Cent Interdisciplinary Ambulance, D-48149 Munster, Germany
关键词
apical transportation; canal straightening; OneShape; Reciproc; shaping ability; WaveOne; CLEANING EFFECTIVENESS; CYCLIC FATIGUE; INSTRUMENTS; MTWO; PROFILE;
D O I
10.1111/iej.12289
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals in extracted human molar teeth. Methodology Sixty mandibular molars with mesio-buccal canals with curvatures ranging between 25 degrees and 35 degrees and radii of curvature ranging between 4 and 9 mm were divided into three groups of 20 teeth each: group W (WaveOne), group R (Reciproc) and group O (OneShape). Using standardized pre -and post-instrumentation radiographs, straightening of canal curvatures was determined using the NIH Image J software. A double-digital standardized radiographic technique was used to determine apical transportation at 0.5 mm from the working length (1.5 mm coronal to the major foramen). Preparation time and instrument failures were also recorded. Data were analysed using one-way analysis of variance (ANOVA) and post-hoc Tukey-test. Results During root canal preparation, no instruments fractured but all OneShape instruments were deformed after preparation of four canals. The use of OneShape resulted in significantly greater canal straightening and apical transportation than WaveOne and Reciproc (P < 0.05), with no significant differences between WaveOne and Reciproc (P > 0.05). Instrumentation with OneShape was significantly faster than with WaveOne and Reciproc (P < 0.05), whilst Reciproc was significantly faster than WaveOne (P < 0.05). Conclusions All instruments were safe to use. Reciproc and WaveOne instruments respected the original canal curvature better than OneShape files. The use of OneShape instruments required less time to prepare the curved canals compared with Reciproc and WaveOne.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 23 条
[1]  
Bürklein S, 2013, INT ENDOD J, V46, P590, DOI [10.1111/iej.12037, 10.1111/iej.12161]
[2]   Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper [J].
Buerklein, S. ;
Hinschitza, K. ;
Dammaschke, T. ;
Schaefer, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (05) :449-461
[3]   Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals [J].
Capar, Ismail Davut ;
Ertas, Huseyin ;
Ok, Evren ;
Arslan, Hakan ;
Ertas, Elif Tarim .
JOURNAL OF ENDODONTICS, 2014, 40 (06) :852-856
[4]   Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement [J].
De-Deus, G. ;
Moreira, E. J. L. ;
Lopes, H. P. ;
Elias, C. N. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (12) :1063-1068
[5]  
Fiedler A, 2014, INT ENDOD J, V47, P78
[6]   Investigation on the Shaping Ability of Nickel-Titanium Files When Used with a Reciprocating Motion [J].
Franco, Vittorio ;
Fabiani, Cristiano ;
Taschieri, Silvio ;
Malentacca, Augusto ;
Bortolin, Monica ;
Del Fabbro, Massimo .
JOURNAL OF ENDODONTICS, 2011, 37 (10) :1398-1401
[7]   A Comparison of Apical Transportation between ProFile and RaCe Rotary Instruments [J].
Garcia, Marc ;
Duran-Sindreu, Fernando ;
Mercade, Montse ;
Bueno, Rufino ;
Roig, Miguel .
JOURNAL OF ENDODONTICS, 2012, 38 (07) :990-992
[8]  
Hulsmann M., 2005, Endodontic Topics, V10, P30, DOI DOI 10.1111/J.1601-1546.2005.00152.X
[9]  
Kim H, 2012, SPACE, P38
[10]   Do procedural errors cause endodontic treatment failure? [J].
Lim, LM ;
Rosenberg, PA ;
Lin, JS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2005, 136 (02) :187-193