Biomechanical evaluation of subcortical versus bicortical screw purchase in anterior cervical plating

被引:16
作者
Chen, IH [1 ]
机构
[1] NATL YANG MING UNIV,SCH MED,TAIPEI,TAIWAN
关键词
anterior cervical fusion; biomechanics; cervical plating;
D O I
10.1007/BF01411356
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this in vitro study is to compare the stabilities provided by anterior cervical H-plating with screws purchased either subcortically or bicortically on porcine cervical spines. Nine porcine cervical spines (C3-C4) were challenged by 12 Nm in extension followed by 6 Nm in flexion in 6 consecutive steps, i.e., (1) when disc was intact, (2) after discectomy. Subsequently, a tricortical bone graft was inserted to simulate interbody fusion. Each specimen was tested again (3) when plated with 16 mm screws to purchase subcortically and (4) after cyclic loading (f = 0.5 Hz, n = 1000), (5) when plated with 30 mm screws to pur chase bicortically and (6) after cyclic loading. Neutral zone and range of motion were parameters normalized for comparison. The results showed comparable stability in constructs plated with screws purchased either subcortically or bicortically before cyclic loading. Cyclic loading deteriorated construct-bone relation in both groups, yet bicortically purchased screws rendered additional stability in anterior cervical plating.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [31] Biomechanical rigidity of cadaveric cervical spine with posterior versus combined posterior and anterior instrumentation Laboratory investigation
    Dahdaleh, Nader S.
    Nakamura, Satoshi
    Torner, James C.
    Lim, Tae-Hong
    Hitchon, Patrick W.
    JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (02) : 133 - 138
  • [32] INTERNAL-FIXATION OF THE UNSTABLE ANTERIOR PELVIC RING - A BIOMECHANICAL COMPARISON OF STANDARD PLATING TECHNIQUES AND THE RETROGRADE MEDULLARY SUPERIOR PUBIC RAMUS SCREW
    SIMONIAN, PT
    ROUTT, MLC
    HARRINGTON, RM
    TENCER, AF
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (06) : 476 - 482
  • [33] Augmentation of anterior lumbar interbody fusion with anterior pedicle screw fixation: Demonstration of novel constructs and evaluation of biomechanical stability in cadaveric specimens
    Karim, A
    Mukherjee, D
    Ankem, M
    Gonzalez-Cruz, J
    Smith, D
    Nanda, A
    NEUROSURGERY, 2006, 58 (03) : 522 - 527
  • [34] BIOMECHANICAL ANALYSIS OF BONE-MINERAL DENSITY, INSERTION TECHNIQUE, SCREW TORQUE, AND HOLDING STRENGTH OF ANTERIOR CERVICAL PLATE SCREWS
    RYKEN, TC
    CLAUSEN, JD
    TRAYNELIS, VC
    GOEL, VK
    JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 324 - 329
  • [35] Interference screw versus Endoscrew fixation for anterior cruciate ligament reconstruction: A biomechanical comparative study in sawbones and porcine knees
    Hung, Chu-Chih
    Chen, Wen-Chuan
    Yang, Chan-Tsung
    Cheng, Cheng-Kung
    Chen, Chih-Hwa
    Lai, Yu-Shu
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2014, 2 (02) : 82 - 90
  • [36] Biomechanics of one-level anterior cervical discectomy and plating using two screws versus four screws
    Crawford, Neil R.
    Scholz, Matti
    Reyes, Phillip M.
    Schleicher, Philipp
    Brasiliense, Leonardo B. C.
    Sawa, Anna G. U.
    Baek, Seungwon
    Marciano, Frederick F.
    Kandziora, Frank M.
    SPINE JOURNAL, 2011, 11 (03) : 234 - 240
  • [37] Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures – a biomechanical investigation
    Karl Stoffel
    Ivan Zderic
    Torsten Pastor
    William Woodburn
    Richard Castle
    Jessica Penman
    Eladio Saura-Sanchez
    Boyko Gueorguiev
    Christoph Sommer
    BMC Musculoskeletal Disorders, 24
  • [38] Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation
    Stoffel, Karl
    Zderic, Ivan
    Pastor, Torsten
    Woodburn, William
    Castle, Richard
    Penman, Jessica
    Saura-Sanchez, Eladio
    Gueorguiev, Boyko
    Sommer, Christoph
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [39] Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation
    Strauss, Eric
    Frank, Joshua
    Lee, Jason
    Kummer, Frederick J.
    Tejwani, Nirmal
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (10): : 984 - 989
  • [40] Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
    Geert A. Buijze
    Leendert Blankevoort
    Gabriëlle J. M. Tuijthof
    Inger N. Sierevelt
    Peter Kloen
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 459 - 464