Biomechanical evaluation of subcortical versus bicortical screw purchase in anterior cervical plating

被引:16
|
作者
Chen, IH [1 ]
机构
[1] NATL YANG MING UNIV,SCH MED,TAIPEI,TAIWAN
关键词
anterior cervical fusion; biomechanics; cervical plating;
D O I
10.1007/BF01411356
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this in vitro study is to compare the stabilities provided by anterior cervical H-plating with screws purchased either subcortically or bicortically on porcine cervical spines. Nine porcine cervical spines (C3-C4) were challenged by 12 Nm in extension followed by 6 Nm in flexion in 6 consecutive steps, i.e., (1) when disc was intact, (2) after discectomy. Subsequently, a tricortical bone graft was inserted to simulate interbody fusion. Each specimen was tested again (3) when plated with 16 mm screws to purchase subcortically and (4) after cyclic loading (f = 0.5 Hz, n = 1000), (5) when plated with 30 mm screws to pur chase bicortically and (6) after cyclic loading. Neutral zone and range of motion were parameters normalized for comparison. The results showed comparable stability in constructs plated with screws purchased either subcortically or bicortically before cyclic loading. Cyclic loading deteriorated construct-bone relation in both groups, yet bicortically purchased screws rendered additional stability in anterior cervical plating.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [21] Interference Screw versus Cement Fixation in Anterior Cruciate Ligament Soft Tissue Grafts: A Biomechanical Study
    Patel, Jay
    Kadkoy, Yazan
    Helbig, Thomas
    Rupani, Mohammed
    Cuppari, Nicholas
    Cortes, Ricardo
    Wetterstrand, Charlene
    Lu, Michael T.
    Paglia, David N.
    Galdi, Balazs
    Beiro, Cristobal
    JOURNAL OF KNEE SURGERY, 2024, 37 (04) : 326 - 332
  • [22] Screw- versus plate-fixation strength of acetabular anterior column fractures: A biomechanical study
    Gras, Florian
    Marintschev, Ivan
    Schwarz, Christoph E.
    Hofmann, Gunther O.
    Pohlemann, Tim
    Culemann, Ulf
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (06) : 1664 - 1670
  • [23] A biomechanical comparison of superior ramus plating versus intramedullary screw fixation for unstable lateral compression pelvic ring injuries
    Hempen, Eric C.
    Wheatley, Benjamin M.
    Schimoler, Patrick J.
    Kharlamov, Alexander
    Melvin, Patricia R.
    Miller, Mark Carl
    Altman, Gregory T.
    Altman, Daniel T.
    Westrick, Edward R.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 3899 - 3903
  • [24] Standalone versus Anterior Cervical Plating for One-To-Two Level Anterior Cervical Discectomy and Fusion: A Propensity Score-Matched Comparative Study
    Baig, Ammad A.
    Aguirre, Alexander O.
    Solimaan, Mohamed A. R.
    Kuo, Cathleen C.
    Lim, Jaims
    Khan, Asham
    Chen, Ivette
    Snyder, Kenneth, V
    Levy, Elad I.
    Siddiqui, Adnan H.
    Pollina, John
    Mullin, Jeffrey P.
    WORLD NEUROSURGERY, 2023, 177 : E673 - E679
  • [25] Biomechanical Comparison of Bicortical Locking Versus Unicortical Far-Cortex-Abutting Locking Screw-Plate Fixation for Comminuted Radial Shaft Fractures
    Overturf, Steven J.
    Morris, Randal P.
    Gugala, Zbigniew
    Lindsey, Ronald W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (10): : 1907 - 1913
  • [26] Cage-screw and anterior plating combination reduces the risk of micromotion and subsidence in multilevel anterior cervical discectomy and fusion-a finite element study
    Lin, Maohua
    Shapiro, Stephen Z.
    Doulgeris, James
    Engeberg, Erik D.
    Tsai, Chi-Tay
    Vrionis, Frank D.
    SPINE JOURNAL, 2021, 21 (05) : 874 - 882
  • [27] Less invasive stabilization of complex tibial plateau fractures -: A biomechanical evaluation of a unilateral locked screw plate and double plating
    Gösling, T
    Schandelmaier, P
    Marti, A
    Hufner, T
    Partenheimer, A
    Krettek, C
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 546 - 551
  • [28] Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine
    Reitman, CA
    Nguyen, L
    Fogel, GR
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2004, 17 (04): : 306 - 311
  • [29] Biomechanical evaluation of subpectoral biceps tenodesis: dual suture anchor versus interference screw fixation
    Tashjian, Robert Z.
    Henninger, Heath B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (10) : 1408 - 1412
  • [30] Comparison of biomechanical response to surgical procedures used for cervical radiculopathy: Posterior keyhole foraminotomy versus anterior foraminotomy and discectomy versus anterior discectomy with fusion
    Chen, BH
    Natarajan, RN
    An, HS
    Andersson, GBJ
    JOURNAL OF SPINAL DISORDERS, 2001, 14 (01): : 17 - 20