Biomechanical evaluation of subcortical versus bicortical screw purchase in anterior cervical plating

被引:16
|
作者
Chen, IH [1 ]
机构
[1] NATL YANG MING UNIV,SCH MED,TAIPEI,TAIWAN
关键词
anterior cervical fusion; biomechanics; cervical plating;
D O I
10.1007/BF01411356
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this in vitro study is to compare the stabilities provided by anterior cervical H-plating with screws purchased either subcortically or bicortically on porcine cervical spines. Nine porcine cervical spines (C3-C4) were challenged by 12 Nm in extension followed by 6 Nm in flexion in 6 consecutive steps, i.e., (1) when disc was intact, (2) after discectomy. Subsequently, a tricortical bone graft was inserted to simulate interbody fusion. Each specimen was tested again (3) when plated with 16 mm screws to purchase subcortically and (4) after cyclic loading (f = 0.5 Hz, n = 1000), (5) when plated with 30 mm screws to pur chase bicortically and (6) after cyclic loading. Neutral zone and range of motion were parameters normalized for comparison. The results showed comparable stability in constructs plated with screws purchased either subcortically or bicortically before cyclic loading. Cyclic loading deteriorated construct-bone relation in both groups, yet bicortically purchased screws rendered additional stability in anterior cervical plating.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [1] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Lehmann, W
    Blauth, M
    Briem, D
    Schmidt, U
    EUROPEAN SPINE JOURNAL, 2004, 13 (01) : 69 - 75
  • [2] Biomechanical analysis of anterior cervical spine plate fixation systems with unicortical and bicortical screw purchase
    Wolfgang Lehmann
    Michael Blauth
    Daniel Briem
    Ulf Schmidt
    European Spine Journal, 2004, 13 : 69 - 75
  • [3] Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study
    Pitzen, T
    Wilke, HJ
    Caspar, W
    Claes, L
    Steudel, WI
    EUROPEAN SPINE JOURNAL, 1999, 8 (05) : 382 - 387
  • [4] Evaluation of a new monocortical screw for anterior cervical fusion and plating by a combined biomechanical and clinical study
    T. Pitzen
    Hans-Joachim Wilke
    Wolfhard Caspar
    Lutz Claes
    Wolf-Ingo Steudel
    European Spine Journal, 1999, 8 : 382 - 387
  • [5] Biomechanical analysis of bicortical versus unicortical locked plating of mid-clavicular fractures
    Daniel Hamman
    Derek Lindsey
    Jason Dragoo
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 773 - 778
  • [6] Biomechanical evaluation of hydroxyapatite intervertebral graft and anterior cervical plating in a porcine cadaveric model
    Takahashi, T
    Tominaga, T
    Yoshimoto, T
    Koshu, K
    Yokobori, AT
    Aizawa, Y
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1997, 7 (02) : 121 - 127
  • [7] Biomechanical analysis of bicortical versus unicortical locked plating of mid-clavicular fractures
    Hamman, Daniel
    Lindsey, Derek
    Dragoo, Jason
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (06) : 773 - 778
  • [8] Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation
    Eck, Jason C.
    Walker, Matt P.
    Currier, Bradord L.
    Chen, Qingshan
    Yaszemski, Michael J.
    An, Kai-Nan
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (07): : 505 - 508
  • [9] Biomechanical evaluation of anterior cervical spine stabilization
    Grubb, MR
    Currier, BL
    Shih, JS
    Bonin, V
    Grabowski, JJ
    Chao, EYS
    SPINE, 1998, 23 (08) : 886 - 892
  • [10] Biomechanical Evaluation of Parasagittal Occipital Plating Screw Load Sharing Analysis
    Frush, Todd J.
    Fisher, Theodore J.
    Ensminger, Scott C.
    Truumees, Eeric
    Demetropoulos, Constantine K.
    SPINE, 2009, 34 (09) : 877 - 884