The paper reviews and discusses the main factors, limiting the accuracy of polarimetric measurements in tokamak plasma. Theoretical methods, describing evolution of polarimetry state in tokamak plasma, are demonstrated not to contribute noticeably to inaccuracy at sufficiently short beam wavelengths. Based on the literature data as well as on our preliminary estimates it is possible to conclude that the following factors dominate: i) calibration procedure; ii) refraction in the inhomogeneous plasma; iii) influence of weak relativistic effects on plasma dielectric permittivity. The contribution of these factors to is within the range of several per cent. Other causes of measurement inaccuracies (absorption in plasma, diffraction of sounding beam, ray torsion, nonstationary processes in plasma) seem to be less significant. (C) 2014 The Authors. Published by Elsevier B.V.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 31 条
  • [1] BIEG B, QUASI ISOTROPIC APPR
  • [2] BIEG B, 2008, P SOC PHOTO-OPT INS, V7141
  • [3] Calibration procedure for plasma polarimetry based on the complex amplitude ratio measurements
    Bieg, Bohdan
    Kravtsov, Yury A.
    Cieplik, Marek
    [J]. FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1452 - 1454
  • [4] Born M., 1999, Principles of optics, Vseventh
  • [5] POLARIZATION OF AN E M WAVE PROPAGATING IN A PLASMA WITH MAGNETIC SHEAR - MEASUREMENT OF POLOIDAL MAGNETIC-FIELD IN TOKAMAK
    DEMARCO, F
    SEGRE, SE
    [J]. PLASMA PHYSICS, 1972, 14 (03): : 245 - &
  • [6] Poloidal polarimeter system for current density measurements in ITER
    Donné, AJH
    Edlington, T
    Joffrin, E
    Koslowski, HR
    Nieswand, C
    Segre, SE
    Stott, PE
    Walker, C
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) : 726 - 729
  • [7] Spurious oscillations affecting FIR polarimetry measurements
    Elbèze, D
    Gil, C
    Giannella, R
    De Pasqual, L
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) : 3405 - 3407
  • [8] Experimental verification of relativistic finite temperature polarimetry effects at JET
    Ford, O. P.
    Svensson, J.
    Boboc, A.
    McDonald, D. C.
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2009, 51 (06)
  • [9] Fuki A.A., 1997, GEOMETRICAL OPTICS W
  • [10] GELFUSA M, 2010, REV SCI INSTRUM, V81