High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion

被引:4
作者
Nahhas, Cindy R. [1 ]
Yi, Paul H. [2 ]
Moric, Mario [1 ]
Puri, Rajeev [3 ]
Jacobs, Joshua J. [1 ]
Sporer, Scott M. [1 ]
机构
[1] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[3] Riverside Hosp, Dept Orthoped Surg, Kankakee, IL USA
关键词
primary total hip arthroplasty; modular neck; modularity; cementless; survivorship; STEM; COMPONENT; HEAD; DISSOCIATION; INTERFACES; CORROSION; OUTCOMES;
D O I
10.1016/j.arth.2019.03.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Modular femoral trunnions enable the surgeon to independently adjust offset, leg length, and anteversion in total hip arthroplasty (THA). However, modularity may result in an increased risk of fretting and corrosion along with a higher risk of implant dissociation or fracture. The purpose of this study is to evaluate mid-term survivorship of THAs using a cementless modular system. Methods: A consecutive series of 221 patients who underwent a primary THA using the ALFA II modular stem by a single surgeon between 2002 and 2004 were reviewed. Survivorship of the ALFA II modular hip system was evaluated at a minimum of 5 years postoperatively. Results: Of the 221 patients, 28 (12.7%) died from causes unrelated to the surgery before adequate follow-up, and 64 (29.0%) patients were lost to follow-up. The remaining 129 patients had a mean 6.5-year (range: 5-8 years) follow-up. All-cause survivorship of the modular stem system was 81% (95% confidence interval = 69-90) at a mean 6.5-year follow-up. Of the 25 (19.4%) cases requiring revision surgery, 52.0% was for dissociation of the modular components, 32.0% was for fracture of the prosthesis, 12.0% was for instability/multiple dislocations, and 4.0% was for chronic septic THA. Body mass index (odds ratio = 1.080) and offset (odds ratio = 1.254) were independent risk factors for mechanical failures of the modular stem system. Conclusion: The modular stem hip system of interest in this study demonstrates a high failure rate at mid-term follow-up, and we caution against the use of similar designs in primary THAs. Published by Elsevier Inc.
引用
收藏
页码:1395 / 1399
页数:5
相关论文
共 24 条
[1]  
Baleani M, 1997, Chir Organi Mov, V82, P231
[2]   Mid-term results of an uncemented femoral stem with modular neck options [J].
Benazzo, Francesco ;
Rossi, Stefano M. P. ;
Cecconi, Davide ;
Piovani, Lucio ;
Ravasi, Flavio .
HIP INTERNATIONAL, 2010, 20 (04) :427-433
[3]   Mid-term results of the modular ANCA-Fit femoral component in total hip replacement [J].
Blakey, C. M. ;
Eswaramoorthy, V. K. ;
Hamilton, L. C. ;
Biant, L. C. ;
Field, R. E. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (12) :1561-1565
[4]   Modular Tapered Implants for Severe Femoral Bone Loss in THA: Reliable Osseointegration but Frequent Complications [J].
Brown, Nicholas M. ;
Tetreault, Matthew ;
Cipriano, Cara A. ;
Della Valle, Craig J. ;
Paprosky, Wayne ;
Sporer, Scott .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) :555-560
[5]   Primary total hip arthroplasty with use of the modular S-ROM prosthesis - Four to seven-year clinical and radiographic results [J].
Christie, MJ ;
DeBoer, DK ;
Trick, LW ;
Brothers, JC ;
Jones, RE ;
Vise, GT ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (12) :1707-1716
[6]   Dissociation of modular total hip arthroplasty at the femoral head-neck interface after loosening of the acetabular shell following hip dislocation [J].
Chu, CM ;
Wang, SJ ;
Lin, LC .
JOURNAL OF ARTHROPLASTY, 2001, 16 (06) :806-809
[7]  
COOK SD, 1994, CLIN ORTHOP RELAT R, P80
[8]   Long-term survivorship and complication rate comparison of a cementless modular stem and cementless fixed neck stems for primary total hip replacement [J].
Fitch, David A. ;
Ancarani, Cristina ;
Bordini, Barbara .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) :1827-1832
[9]  
Goldberg JR, 2002, CLIN ORTHOP RELAT R, P149
[10]   Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty [J].
Hoberg, Maik ;
Konrads, Christian ;
Engelien, Jana ;
Oschmann, Dorothee ;
Holder, Michael ;
Walcher, Matthias ;
Rudert, Maximilian .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) :1709-1713