Are Drug-Eluting Stents Safer and More Effective Than Bare-Metal Stents in Patients With Acute Myocardial Infarction?

被引:1
作者
Lee, Ki Hong [1 ]
Ahn, Youngkeun [1 ]
Yoon, Nam Sik [1 ]
Yoon, Hyun Ju [1 ]
Hong, Young Joon [1 ]
Kim, Kye Hun [1 ]
Park, Hyung Wook [1 ]
Kim, Ju Han [1 ]
Jeong, Myung Ho [1 ]
Cho, Jeong Gwan [1 ]
Park, Jong Chun [1 ]
Kang, Jung Chaee [1 ]
机构
[1] Chonnam Natl Univ Hosp, Ctr Heart, Dept Cardiol, Kwangju 501757, South Korea
关键词
Acute myocardial infarction; Drug-eluting stent; Bare-metal stent; PERCUTANEOUS CORONARY INTERVENTION; TERM CLINICAL-OUTCOMES; ARTERY-DISEASE; CARDIAC EVENTS; REGISTRY; THROMBOSIS; IMPLANTATION; METAANALYSIS; TRIALS; PREDICTORS;
D O I
10.1536/ihj.52.78
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Questions about the long-term safety over the beneficial effects of drug-eluting stents (DES) have grown. We compared the long-term safety and efficacy of DES and bare-metal stents (BMS) in patients with acute myocardial infarction (AMI). A total of 1,017 AMI patients treated with stent implantation were followed for 3 years; 660 (64.9%) patients were treated with at least one DES and 357 (35.1%) patients were treated with at least one BMS. The primary endpoints were total mortality and the composite of major adverse cardiac events (MACE) including total mortality, re-MI, target lesion revascularization (TLR), and coronary artery bypass graft. At 3-years, the overall risks of cardiac and all-cause mortality were not different between the groups. However, the use of DES significantly decreased TLR (17.4% versus 7.1%, adjusted hazard ratio [HR] 0.44, 95% confidence interval [Cl] 0.30 to 0.65) and the composite of MACEs (27.2% versus 19.5%, adjusted HR 0.65, 95% Cl 0.48 to 0.87) with no differences in MI. The risk of MACE up to 1 year (HR 0.56, 95% Cl 0.39 to 0.80) was higher in BMS patients, whereas from 1 year to 2 years (HR 0.55, 95% Cl 0.27 to 1.10) and from 2 years to 3 years (HR 1.13, 95% CI 0.56 to 2.28), it was similar between the groups. The use of DES does not have a significant effect on overall long-term clinical survival compared with that of BMS in AMI patients. However, the use of DES reduced the need for re-intervention and the risk of MACE, mostly within 1 year. (Int Heart J 2011; 52: 78-83)
引用
收藏
页码:78 / 83
页数:6
相关论文
共 50 条
[21]   Paclitaxel-Eluting Stents versus Bare-Metal Stents in Acute Myocardial Infarction. [J].
Stone, Gregg W. ;
Lansky, Alexandra J. ;
Pocock, Stuart J. ;
Gersh, Bernard J. ;
Dangas, George ;
Wong, S. Chiu ;
Witzenbichler, Bernhard ;
Guagliumi, Giulio ;
Peruga, Jan Z. ;
Brodie, Bruce R. ;
Dudek, Dariusz ;
Moeckel, Martin ;
Ochala, Andrzej ;
Kellock, Alison ;
Parise, Helen ;
Mehran, Roxana .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (19) :1946-1959
[22]   Drug-eluting stents versus bare-metal stents for saphenous vein graft interventions [J].
Shah, Rahman ;
Hesterberg, Kirstin .
JOURNAL OF THORACIC DISEASE, 2019, 11 :S1257-S1260
[23]   Mortality following placement of drug-eluting and bare-metal stents for ST-segment elevation acute myocardial infarction in the Global Registry of Acute Coronary Events [J].
Steg, Ph. Gabriel ;
Fox, Keith A. A. ;
Eagle, Kim A. ;
Furman, Mark ;
Van de Werf, Frans ;
Montalescot, Gilles ;
Goodman, Shaun G. ;
Avezum, Alvaro ;
Huang, Wei ;
Gore, Joel M. .
EUROPEAN HEART JOURNAL, 2009, 30 (03) :321-329
[24]   Long-Term Outcome of Drug-Eluting vs. Bare-Metal Stents in Patients With Acute Myocardial Infarction - Subgroup Analysis of the Nagoya Acute Myocardial Infarction Study (NAMIS) [J].
Suzuki, Susumu ;
Ishii, Hideki ;
Matsudaira, Kyoko ;
Okumura, Naoki ;
Yoshikawa, Daiji ;
Hayashi, Mutsuhara ;
Maeda, Kengo ;
Kondo, Takahisa ;
Kondo, Taizo ;
Ichimiya, Satoshi ;
Kato, Rinya ;
Matsubara, Tatsuaki ;
Murohara, Toyoaki .
CIRCULATION JOURNAL, 2013, 77 (08) :2024-2031
[25]   Pathology of Chronic Total Occlusion in Bare-Metal Versus Drug-Eluting Stents [J].
Mori, Hiroyoshi ;
Lutter, Christoph ;
Yahagi, Kazuyuki ;
Harari, Emanuel ;
Kutys, Robert ;
Fowler, David R. ;
Ladich, Elena ;
Joner, Michael ;
Virmani, Renu ;
Finn, Aloke V. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (04) :367-378
[26]   Meta-Analysis of Comparison of Drug-Eluting Stents and Bare-Metal Stents in Patients on Dialysis [J].
Li, Shan ;
Ye, Dan ;
Chen, Guoping ;
Xu, Weiwei .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (08) :1186-1192
[27]   Drug-eluting versus bare-metal stents for saphenous vein graft lesions [J].
Conte, Sean M. ;
Florisson, Daniel S. ;
De Bono, Joshua A. ;
Vale, Peter R. .
INTERNAL MEDICINE JOURNAL, 2019, 49 (12) :1534-1537
[28]   Time Dependency of Outcomes for Drug-Eluting vs Bare-Metal Stents [J].
Leung, Alexander A. ;
Southern, Danielle A. ;
Galbraith, P. Diane ;
Knudtson, Merril L. ;
Philpott, Andrew C. ;
Ghali, William A. .
CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (12) :1616-1622
[29]   Effect of Length and Diameter of Drug-Eluting Stents Versus Bare-Metal Stents on Late Outcomes [J].
Applegate, Robert J. ;
Sacrinty, Matthew T. ;
Kutcher, Michael A. ;
Santos, Renato M. ;
Gandhi, Sanjay K. ;
Little, William C. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (01) :35-42
[30]   Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease [J].
Bonaa, K. H. ;
Mannsverk, J. ;
Wiseth, R. ;
Aaberge, L. ;
Myreng, Y. ;
Nygard, O. ;
Nilsen, D. W. ;
Klow, N. -E. ;
Uchto, M. ;
Trovik, T. ;
Bendz, B. ;
Stavnes, S. ;
Bjornerheim, R. ;
Larsen, A. -I. ;
Slette, M. ;
Steigen, T. ;
Jakobsen, O. J. ;
Bleie, O. ;
Fossum, E. ;
Hanssen, T. A. ;
Dahl-Eriksen, O. ;
Njolstad, I. ;
Rasmussen, K. ;
Wilsgaard, T. ;
Nordrehaug, J. E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (13) :1242-1252