Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats

被引:12
|
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Cook, James [1 ]
Berridge, Brian R. [2 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] GlaxoSmithKline Safety Assessment, Res Triangle Pk, NC 27709 USA
关键词
Cardiac; Small animal imaging; Lung; Micro-CT; Stress; Dobutamine; COMPUTED-TOMOGRAPHY; CONTRAST AGENT; MOUSE HEART; MASS; RECONSTRUCTION; MODEL; MRI;
D O I
10.1016/j.vascn.2010.04.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [31] Micro-CT analysis of chronic apical periodontitis induced by several specific pathogens
    Chen, S.
    Lei, H.
    Luo, Y.
    Jiang, S.
    Zhang, M.
    Lv, H.
    Cai, Z.
    Huang, X.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (07) : 1028 - 1039
  • [32] Micro-CT imaging of Randall's plaques
    Williams, James C., Jr.
    Lingeman, James E.
    Coe, Fredric L.
    Worcester, Elaine M.
    Evan, Andrew P.
    UROLITHIASIS, 2015, 43 (01) : S13 - S17
  • [33] Development and evaluation of a high performance micro-CT system for insect or small animal imaging
    Gui, Jianbao
    Zou, Jing
    Rong, Junyan
    Hu, Zhanli
    Li, Yanming
    Xi, Dongxing
    Zheng, Hairong
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [34] Detector-trigger-based cardiac multiphase micro-CT imaging for small animals
    Shi, Yu
    Li, Juntao
    Li, Ke
    Zhang, Xuexue
    Chang, Peng
    Huang, Zujian
    Liu, Yanyun
    Wang, Yihan
    Zhan, Yonghua
    Cao, Xu
    Zhu, Shouping
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (05) : 1047 - 1066
  • [35] Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization
    Clark, Darin
    Badea, Alexandra
    Liu, Yilin
    Johnson, G. Allan
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (19) : 6125 - 6145
  • [36] Micro-CT imaging of breast tumors in rodents using a liposomal, nanoparticle contrast agent
    Samei, Ehsan
    Saunders, Robert S.
    Badea, Cristian T.
    Ghaghada, Ketan B.
    Hedlund, Laurence W.
    Qi, Yi
    Yuan, Hong
    Bentley, Rex C.
    Mukundan, Srinivasan, Jr.
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2009, 4 : 277 - 282
  • [37] Left ventricle volume measurements in cardiac micro-CT: The impact of radiation dose and contrast agent
    Badea, Cristian T.
    Wetzel, Arthur W.
    Mistry, Nilesh
    Pomerantz, Stuart
    Nave, Demian
    Johnson, G. Allan
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (03) : 239 - 250
  • [38] Dobutamine-induced Takotsubo syndrome during stress echocardiogram - An unusual but potentially severe association
    Mangolini, Vitor Iglesias
    Baron, Gabriel Bernardes
    Amaro, Guilherme
    Lipari, Layara
    Amstalden, Natalia
    Dantas, Rafael Tourinho
    Bastos, Pedro Augusto
    Andreucci Torres Lea, Tatiana de Carvalho
    Soeiro, Alexandre de Matos
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2020, 66 (06): : 724 - 727
  • [39] Quantification of the mandibular defect healing by micro-CT morphometric analysis in rats
    Kustro, T.
    Kiss, T.
    Chernohorskyi, D.
    Chepurnyi, Y.
    Helyes, Z.
    Kopchak, A.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (12) : 2203 - 2213
  • [40] Synchrotron-Based Micro-CT Imaging of the Human Lung Acinus
    Litzlbauer, Horst Detlef
    Korbel, Kathrin
    Kline, Timothy L.
    Jorgensen, Steven M.
    Eaker, Diane R.
    Bohle, Rainer M.
    Ritman, Erik L.
    Langheinrich, Alexander C.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2010, 293 (09): : 1607 - 1614