Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats

被引:12
|
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Cook, James [1 ]
Berridge, Brian R. [2 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] GlaxoSmithKline Safety Assessment, Res Triangle Pk, NC 27709 USA
关键词
Cardiac; Small animal imaging; Lung; Micro-CT; Stress; Dobutamine; COMPUTED-TOMOGRAPHY; CONTRAST AGENT; MOUSE HEART; MASS; RECONSTRUCTION; MODEL; MRI;
D O I
10.1016/j.vascn.2010.04.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [21] A Monte Carlo Tool for Micro-CT Dose Assessment
    Deak, P.
    Kalender, W. A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 338 - 341
  • [22] Imaging Techniques for the Assessment of the Bone Osteoporosis-Induced Variations with Particular Focus on Micro-CT Potential
    Molino, Giulia
    Montalbano, Giorgia
    Pontremoli, Carlotta
    Fiorilli, Sonia
    Vitale-Brovarone, Chiara
    APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 27
  • [23] Detection of the Optimal Reconstruction Window for Respiratory-Gated Micro-CT Imaging
    Ertel, D.
    Kyriakou, Y.
    Kalender, W. A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 87 - 90
  • [24] Cardiac Micro-CT Using ECG Gating Signal for Small Animal Imaging
    Guo, Xiaolian
    Tian, Feng
    Tang, Zhiwei
    Hu, Guangshu
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 149 - 152
  • [25] Quantitative Analysis of Micro-CT Imaging and Histopathological Signatures of Experimental Arthritis in Rats
    Silva, Matthew D.
    Savinainen, Anneli
    Kapadia, Rasesh
    Ruan, Jason
    Siebert, Elizabeth
    Avitahl, Nicole
    Mosher, Rebecca
    Anderson, Karen
    Jaffee, Bruce
    Schopf, Lisa
    Chandra, Sudeep
    MOLECULAR IMAGING, 2004, 3 (04): : 312 - 318
  • [26] High Resolution Spectral Micro-CT Imaging of Atherosclerotic Plaque
    Zainon, R.
    Butler, P. H.
    Gieseg, S. P.
    Janmale, T.
    Ronaldson, J. P.
    Anderson, N. G.
    Butler, A. P. H.
    Scott, N. J.
    2014 IEEE REGION 10 SYMPOSIUM, 2014, : 568 - 571
  • [27] Virtual monoenergetic micro-CT imaging in mice with artificial intelligence
    van der Heyden, Brent
    Roden, Stijn
    Dok, Rueveyda
    Nuyts, Sandra
    Sterpin, Edmond
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [28] High-resolution local imaging using a micro-CT
    Lee, Soo Yeol
    Cho, Min Hyoung
    Choi, Jeong Min
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 137 - 140
  • [29] A micro-CT system for little animal imaging
    Zhong, AJ
    Ye, C
    Luo, QM
    PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 330 - 335
  • [30] Micro-CT imaging of Randall’s plaques
    James C. Williams
    James E. Lingeman
    Fredric L. Coe
    Elaine M. Worcester
    Andrew P. Evan
    Urolithiasis, 2015, 43 : 13 - 17