Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats

被引:12
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Cook, James [1 ]
Berridge, Brian R. [2 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] GlaxoSmithKline Safety Assessment, Res Triangle Pk, NC 27709 USA
关键词
Cardiac; Small animal imaging; Lung; Micro-CT; Stress; Dobutamine; COMPUTED-TOMOGRAPHY; CONTRAST AGENT; MOUSE HEART; MASS; RECONSTRUCTION; MODEL; MRI;
D O I
10.1016/j.vascn.2010.04.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 24 条
[1]  
Badea C., 2005, MOL IMAGING, V4, P110
[2]   A dual micro-CT system for small animal imaging - art. no. 691342 [J].
Badea, C. T. ;
Johnston, S. ;
Johnson, B. ;
Lin, M. ;
Hedlund, L. W. ;
Johnson, G. Allan .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913 :91342-91342
[3]   Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice [J].
Badea, Cristian T. ;
Hedlund, Laurence W. ;
Mackel, Julie F. Boslego ;
Mao, Lan ;
Rockman, Howard A. ;
Johnson, G. Allan .
MOLECULAR IMAGING, 2007, 6 (04) :261-268
[4]   Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction [J].
Brau, ACS ;
Hedlund, LW ;
Johnson, GA .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :31-38
[5]   Four-dimensional MR microscopy of the mouse heart using radial acquisition and liposomal gadolinium contrast agent [J].
Bucholz, Elizabeth ;
Ghaghada, Ketan ;
Qi, Yi ;
Mukundan, Srinivasan ;
Johnson, G. Allan .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) :111-118
[6]  
Camici PG, 2003, J NUCL MED, V44, P1662
[7]   Cine and tagged cardiovascular magnetic resonance imaging in normal rat at 1.5 T: a rest and stress study [J].
Daire, Jean-Luc ;
Jacob, Jean-Pascal ;
Hyacinthe, Jean-Noel ;
Croisille, Pierre ;
Montet-Abou, Karin ;
Richter, Sophie ;
Botsikas, Diomidis ;
Lepetit-Coiffe, Matthieu ;
Morel, Denis ;
Vallee, Jean-Paul .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
[8]   Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice [J].
Drangova, Maria ;
Ford, Nancy L. ;
Detombe, Sarah A. ;
Wheatley, Andrew R. ;
Holdsworth, David W. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (02) :85-94
[9]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[10]   Magnetic resonance imaging accurately estimates LV mass in a transgenic mouse model of cardiac hypertrophy [J].
Franco, F ;
Dubois, SK ;
Peshock, RM ;
Shohet, RV .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H679-H683