Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats

被引:12
|
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Cook, James [1 ]
Berridge, Brian R. [2 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] GlaxoSmithKline Safety Assessment, Res Triangle Pk, NC 27709 USA
关键词
Cardiac; Small animal imaging; Lung; Micro-CT; Stress; Dobutamine; COMPUTED-TOMOGRAPHY; CONTRAST AGENT; MOUSE HEART; MASS; RECONSTRUCTION; MODEL; MRI;
D O I
10.1016/j.vascn.2010.04.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [1] Temporal and spectral imaging with micro-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    MEDICAL PHYSICS, 2012, 39 (08) : 4943 - 4958
  • [2] Advances in micro-CT imaging of small animals
    Clark, D. P.
    Badea, C. T.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 175 - 192
  • [3] In Vivo Imaging of MSCT and Micro-CT: a Comparison
    Schwarz, M.
    Engelhorn, T.
    Eyupoglu, I. Y.
    Bruenner, H.
    Struffert, T.
    Kalender, W.
    Doerfler, A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (04): : 322 - 326
  • [4] Body fat of rats of different age groups and nutritional states: assessment by micro-CT and skinfold thickness
    Tekus, Eva
    Miko, Alexandra
    Furedi, Nora
    Rostas, Ildiko
    Tenk, Judit
    Kiss, Tamas
    Szitter, Istvan
    Balasko, Marta
    Helyes, Zsuzsanna
    Wilhelm, Marta
    Petervari, Erika
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 124 (02) : 268 - 275
  • [5] Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging
    Namati, Eman
    Thiesse, Jacqueline
    Sieren, Jessica C.
    Ross, Alan
    Hoffman, Eric A.
    McLennan, Geoffrey
    MEDICAL PHYSICS, 2010, 37 (09) : 4793 - 4805
  • [6] Imaging of cardiac perfusion of free-breathing small animals using dynamic phase-correlated micro-CT
    Sawall, Stefan
    Kuntz, Jan
    Socher, Michaela
    Knaup, Michael
    Hess, Andreas
    Bartling, Soenke
    Kachelriess, Marc
    MEDICAL PHYSICS, 2012, 39 (12) : 7499 - 7506
  • [7] Low-dose 4D cardiac imaging in small animals using dual source micro-CT
    Holbrook, M.
    Clark, D. P.
    Badea, C. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [8] Monitoring Paraquat-induced Pulmonary Fibrosis in Rats with Micro-CT Finding and Histological Examination
    Wang, Kai-Sung
    Chang, Shih-Hsien
    Lu, Chi-Yuan
    Yeh, Chung-Hsin
    Lee, Ming-Wei
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 29 (06) : 312 - 319
  • [9] Lung imaging in rodents using dual energy micro-CT
    Badea, C. T.
    Guo, X.
    Clark, D.
    Johnston, S. M.
    Marshall, C.
    Piantadosi, C.
    MEDICAL IMAGING 2012: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2012, 8317
  • [10] Micro-CT with respiratory and cardiac gating
    Badea, C
    Hedlund, LW
    Johnson, GA
    MEDICAL PHYSICS, 2004, 31 (12) : 3324 - 3329