Hierarchical Task Impedance Control of a Serial Manipulator for Minimally Invasive Surgery

被引:1
|
作者
Su, Hang [1 ]
Yang, Chenguang [2 ]
Li, Jiehao [3 ]
Jiang, Yiming [4 ]
Ferrigno, Giancarlo [1 ]
De Momi, Elena [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[2] Univ West England, Bristol Robot Lab, Bristol, Avon, England
[3] Beijing Inst Technol, State Key Lab Intelligent Control & Decis Complex, Beijing, Peoples R China
[4] Hunan Univ, Natl Engn Lab Robot Visual Percept & Control, Changsha, Peoples R China
来源
PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL CONFERENCE ON HUMAN-MACHINE SYSTEMS (ICHMS) | 2020年
基金
欧盟地平线“2020”; 英国工程与自然科学研究理事会;
关键词
Impedance control; Hierarchical task; Minimally invasive surgery; Serial manipulator; Remote center of motion; REDUNDANT MANIPULATORS; ROBOT MANIPULATORS; MOTION; FRAMEWORK;
D O I
10.1109/ichms49158.2020.9209500
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Flexibility and robustness have become key points in the development of surgical robot controller for physical interactions. However, the conventional impedance control schemes unaware of the actual surgical scenario, including complex physical interaction on the robot arm, lead to the loss of accuracy. In this paper, a hierarchical task impedance control scheme is proposed for Minimally Invasive Surgery (MIS) based on an operational space formulation of a 7 DoFs redundant robot. Its redundancy is exploited to guarantee a remote center of motion (RCM) constraint and to provide a flexible workspace for the medical staff to assist physicians. In addition to the achievement of the classical whole-body impedance control, the issue of uncertain disturbances will be addressed by a decoupled adaptive approximation based on a radial basis function neural network (RBFNN) within the control framework. Task performances under the hierarchical task impedance controller were validated and compared with previous work in the literature. Experimental results showed its improved performance in terms of positional error and RCM constraint, regardless of the existing uncertain physical interaction.
引用
收藏
页码:223 / 228
页数:6
相关论文
共 50 条
  • [31] Towards autonomous motion control in minimally invasive robotic surgery
    Prendergast, J. Micah
    Rentschler, Mark E.
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (08) : 741 - 748
  • [32] Force feedback control of robotic forceps for minimally invasive surgery
    Ishii, Chiharu
    Kamei, Yusuke
    INTELLIGENT SYSTEMS AND AUTOMATION, 2008, 1019 : 154 - +
  • [33] FORCE/POSITION IMPEDANCE CONTROL FOR SPACE MANIPULATOR ON ORBIT CLEANING TASK OF SOLAR PANEL
    Zhu A.
    Chen L.
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2023, 55 (11): : 2624 - 2635
  • [34] Position-Based Fractional-Order Impedance Control of a 2 DOF Serial Manipulator
    Kizir, Selcuk
    Elsavi, Ali
    ROBOTICA, 2021, 39 (09) : 1560 - 1574
  • [35] A new approach to minimally invasive neurosurgery with passive manipulator
    Okayasu, H
    Okamoto, J
    Iseki, H
    Fujie, MG
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1362 - 1362
  • [36] Minimally invasive orthognathic surgery
    Carrasco, Rolando
    Fernandez, Maria de los Angeles
    REVISTA MEDICA CLINICA LAS CONDES, 2023, 34 (04): : 269 - 275
  • [37] Anaesthesia and minimally invasive surgery
    Irwin, Michael G.
    Wong, Stanley S. C.
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2012, 13 (02): : 48 - 51
  • [38] Minimally invasive parathyroid surgery
    Miccoli, P
    Monchik, JM
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2000, 14 (11): : 987 - 990
  • [39] A peril of minimally invasive surgery
    Hearn, C
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (04) : 500 - 501
  • [40] Minimally invasive thyroid surgery
    Shimizu, K
    BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2001, 15 (02) : 123 - 137