Ring and peg electrodes for minimally-Invasive and long-term sub-scalp EEG recordings

被引:11
|
作者
Benovitski, Y. B. [1 ]
Lai, A. [2 ]
McGowan, C. C. [1 ]
Burns, O. [1 ]
Maxim, V. [1 ]
Nayagam, D. A. X. [1 ,3 ]
Millard, R. [1 ]
Rathbone, G. D. [1 ]
le Chevoir, M. A. [6 ]
Williams, R. A. [3 ]
Grayden, D. B. [5 ,7 ]
May, C. N. [4 ]
Murphy, M. [2 ]
D'Souza, W. J. [2 ]
Cook, M. J. [2 ]
Williams, C. E. [1 ]
机构
[1] Bion Inst, 384-388 Albert St, Melbourne, Vic 3002, Australia
[2] Univ Melbourne, St Vincents Hosp, Dept Med, Melbourne, Vic, Australia
[3] Univ Melbourne, St Vincents Hosp, Dept Anat Pathol, Melbourne, Vic, Australia
[4] Univ Melbourne, Florey Inst Neurosci & Mental Hlth, Melbourne, Vic, Australia
[5] Univ Melbourne, Dept Elect & Elect Engn, Melbourne, Vic, Australia
[6] Univ Melbourne, Fac Vet & Agr Sci, Melbourne, Vic, Australia
[7] Univ Melbourne, Ctr Neural Engn, Melbourne, Vic, Australia
基金
英国医学研究理事会;
关键词
Long-term EEG; Epilepsy; Sub-scalp electrode; Minimally-invasive; Stable; Removable; EPILEPSY; MISDIAGNOSIS; SHEEP;
D O I
10.1016/j.eplepsyres.2017.06.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Minimally-invasive approaches are needed for long-term reliable Electroencephalography (EEG) recordings to assist with epilepsy diagnosis, investigation and more naturalistic monitoring. This study compared three methods for long-term implantation of sub-scalp EEG electrodes. Methods: Three types of electrodes (disk, ring, and peg) were fabricated from biocompatible materials and implanted under the scalp in five ambulatory ewes for 3 months. Disk electrodes were inserted into sub-pericranial pockets. Ring electrodes were tunneled under the scalp. Peg electrodes were inserted into the skull, close to the dura. EEG was continuously monitored wirelessly. High resolution CT imaging, histopathology, and impedance measurements were used to assess the status of the electrodes at the end of the study. Results: EEG amplitude was larger in the peg compared with the disk and ring electrodes (p < 0.05). Similarly, chewing artifacts were lower in the peg electrodes (p < 0.05). Electrode impedance increased after long-term implantation particularly for those within the bone (p < 0.01). Micro-CT scans indicated that all electrodes stayed within the sub-scalp layers. All pegs remained within the burr holes as implanted with no evidence of extrusion. Eight of 10 disks partially eroded into the bone by 1.0 mm from the surface of the skull. The ring arrays remained within the sub-scalp layers close to implantation site. Histology revealed that the electrodes were encapsulated in a thin fibrous tissue adjacent to the pericranium. Overlying this was a loose connective layer and scalp. Erosion into the bone occurred under the rim of the sub-pericranial disk electrodes. Conclusions: The results indicate that the peg electrodes provided high quality EEG, mechanical stability, and lower chewing artifact. Whereas, ring electrode arrays tunneled under the scalp enable minimal surgical techniques to be used for implantation and removal.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [21] Necker cube reversals during long-term EEG recordings:: Sub-bands of alpha activity
    Isoglu-Alkaç, Ü
    Strüber, D
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2006, 59 (02) : 179 - 189
  • [22] CARDIAC-ARRHYTHMIAS IN LONG-TERM EEG ECG RECORDINGS
    NOUSIAINEN, U
    MERVAALA, E
    TIIHONEN, P
    RIEKKINEN, PJ
    EPILEPSIA, 1986, 27 (05) : 633 - 633
  • [23] Emergence of Persistent Networks in Long-Term Intracranial EEG Recordings
    Kramer, Mark A.
    Eden, Uri T.
    Lepage, Kyle Q.
    Kolaczyk, Eric D.
    Bianchi, Matt T.
    Cash, Sydney S.
    JOURNAL OF NEUROSCIENCE, 2011, 31 (44): : 15757 - 15767
  • [24] Long-term EEG/EMG recordings from chick embryos
    Martinez-Gonzalez, D.
    Rattenborg, N. C.
    Di Pascoli, S.
    Balaban, E.
    Pompeiano, M.
    JOURNAL OF SLEEP RESEARCH, 2012, 21 : 135 - 135
  • [25] Automatic detection of sleep episodes in long-term eeg recordings
    Malafeev, A.
    Wierzbicka, A.
    Wichniak, A.
    Jernajczyk, W.
    Achermann, P.
    JOURNAL OF SLEEP RESEARCH, 2016, 25 : 344 - 344
  • [26] Minimally invasive esophagectomyShort- and long-term outcomes
    S. Leibman
    B. M. Smithers
    D. C. Gotley
    I. Martin
    J. Thomas
    Surgical Endoscopy And Other Interventional Techniques, 2006, 20 : 428 - 433
  • [27] Approaches for Minimally Invasive Long-Term Ecological Monitoring
    Mantegna, Christine
    Roberts, Steven
    Gaynus, Camille
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2024, 64 : S325 - S325
  • [28] Long-term weight loss with a novel minimally-invasive, restrictive bariatric medical device, the Onciomed Gastric Vest System
    Stein, Paul
    Nihalani, Raj
    FASEB JOURNAL, 2014, 28 (01):
  • [29] THE EUROPEAN EEG DATABASE AS A NEW STANDARD FOR LONG-TERM EEG RECORDINGS IN EPILEPSY PATIENTS
    Schulze-Bonhage, A.
    Levanquyen, M.
    Sales, F.
    Neufang, M.
    Dourado, A.
    Ihle, M.
    EPILEPSIA, 2012, 53 : 13 - 13
  • [30] Long-term EEG in ring chromosome 20 syndrome
    De Moura, MAF
    Gargatagli, R
    Gueguen, B
    Biraben, A
    Soufflet, C
    Plouin, P
    de Toffol, B
    EPILEPSIA, 2004, 45 : 167 - 168