X-ray emission from a compact hot plasma:: applications to radiology and mammography

被引:14
作者
Gaudin, C
Lamoureux, M
Rouillé, C
机构
[1] Ecole Polytech, Phys Milieux Ionises Lab, F-91128 Palaiseau, France
[2] Univ Paris 06, Lab Dynam Ion Atomes & Mol, F-75252 Paris 05, France
关键词
D O I
10.1088/0031-9155/46/3/317
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hot. electrons confined in a compact magnetized plasma (in a 1 litre chamber) and heated by electron cyclotron resonance were used to provide an intense reproducible x-ray emission. Since electrons were generated in situ, the use of filaments and high voltages at the base of the x-ray tubes was avoided. The source can be pulsed or operated in a highly stable continuous mode. The spatial and energetic characteristics of the hot electrons were determined via their bremsstrahlung by comparison with theoretical calculations. In this test x-ray source the average energy of the hot electron flux was in the range 10-40 keV, depending on the operating parameters: intermagnet distance (6-9 cm), power of the 2.45 GHz microwave (200-1000 W), chamber pressure (4 x 10(-5) 9 x 10(-5) Torr), The insertion of solid targets into the electron flux leads to various focal spot sizes, enabling application in radiology and mammography, The images of a mammographic phantom were obtained in a few seconds with good contrast (microcalcifications being successfully detected).
引用
收藏
页码:835 / 851
页数:17
相关论文
共 18 条
[1]   A compact radiological X-ray source [J].
Bacal, M ;
Gaudin, C ;
Bourdier, A ;
Bruneteau, J ;
Buzzi, JM ;
Golovanivsky, KS ;
Hay, L ;
Rouille, C ;
Schwartz, L .
NATURE, 1996, 384 (6608) :421-421
[2]   INVESTIGATION OF HOT-ELECTRONS IN ELECTRON-CYCLOTRON-RESONANCE ION SOURCES [J].
BARUE, C ;
LAMOUREUX, M ;
BRIAND, P ;
GIRARD, A ;
MELIN, G .
JOURNAL OF APPLIED PHYSICS, 1994, 76 (05) :2662-2670
[3]  
BUSHONG S, 1992, DIAGNOSTIC IMAGING, P51
[4]  
DYSON NA, 1990, XRAYS ATOMIC NUCL PH, pCH2
[5]   Compact electron cyclotron resonance plasma source [J].
Gaudin, C ;
Hay, L ;
Buzzi, JM ;
Bacal, M ;
Lamoureux, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) :890-892
[6]  
GAUDIN C, 1999, THESIS U P SABATIER
[7]  
GELLER R, 1996, ELECT CYCLOTRON RESO, pCH1
[8]   PROPOSED PHYSICAL MODEL FOR VERY HOT-ELECTRON SHELL STRUCTURES IN ELECTRON-CYCLOTRON RESONANCE-DRIVEN PLASMAS [J].
GOLOVANIVSKY, KS ;
DOUGARJABON, VD ;
REZNIKOV, DV .
PHYSICAL REVIEW E, 1995, 52 (03) :2969-2973
[9]  
HUTCHINSON IH, 1987, PRINCIPLES PLASMA DI, pCH5
[10]   The effect of microwave frequency and grad B on the energy of electrons in an electron cyclotron resonance ion source [J].
Koivisto, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07) :2979-2983