Pump characteristic based optimization of a direct water cooling system for a 10-kW/500-kHz Vienna Rectifier

被引:23
作者
Drofenik, U [1 ]
Laimer, G [1 ]
Kolar, JW [1 ]
机构
[1] ETH, Power Elect Syst Lab, CH-8092 Zurich, Switzerland
关键词
fluid dynamics; multichip power module; pulsewidth modulation (PWM); Vienna Rectifier;
D O I
10.1109/TPEL.2005.846529
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An ultra high power density 10-kW/500-kHz three-phase pulse-width modulation rectifier (Vienna Rectifier) is under development at the Power Electronic Systems Laboratory, ETH Zurich. From preliminary measurements and numerical simulations the total efficiency is assumed to be 95% at full load, resulting in power losses of up to 150 W in each multichip power module that realizes a bridge leg of the rectifier. In order to maintain the required power density of the system high direct water cooling is employed where water is in direct contact with the module base plate. Based on the measured characteristic of the water pump (pressure drop dependent on the water flow rate) the geometry of different water channel structures below the module base plate is systematically optimized based on equations which are formulated using well-established fluid dynamics theory. The design optimization is constrained by the desire to keep the geometry of the water channels in a range which allows simple and low-cost manufacturing. The aim is to find a channel structure resulting in a minimum thermal resistance of the power module for a given pump characteristic. In this paper, a very simple slot channel is investigated. The dependency of the thermal resistance on the cooling system is calculated for various heights of the slot channel, and an optimized channel height is determined using the condition of simple manufacturability. The shortcomings of the simple slot structure are discussed, and a novel metallic inlay structure is introduced and optimized that results in a reduction of the thermal resistance of the direct water cooling scheme as compared to the slot channel system. All theoretical considerations are experimentally verified. The general optimization scheme introduced in this paper can easily be adapted to other cooling problems.
引用
收藏
页码:704 / 714
页数:11
相关论文
共 21 条
[1]  
[Anonymous], DUBBEL TASCHENBUCH M
[2]  
Baehr H.D., 1998, Warme- und Stoffubertragung
[3]  
Drofenik U, 2003, INTELEC'03: POWERING THE BROADBAND NETWORK, PROCEEDINGS, P826
[4]  
*EBM PAPST GERM, DC AX SER 4100N TYP
[5]  
*EH INC, CENTR PUMP 1048
[6]  
*FISCH EL GMBH, HOLL FIN COOL AGGR A
[7]  
*FLUENT INC, 3D CFD FEM SOFTW ICE
[8]  
*FLUK INC, 80 BK INT DMM TEMP P
[9]  
*FUJ INC, PREAMPL PREC PREC PR
[10]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359