Vacuum enclosures for solar thermal panels Part 2: Transient testing with an uncooled absorber plate

被引:11
作者
Arya, Farid [1 ]
Moss, Roger [2 ]
Hyde, Trevor [1 ]
Shire, Stan [2 ]
Henshall, Paul [3 ]
Eames, Philip [4 ]
机构
[1] Ulster Univ, Ctr Sustainable Technol, Coleraine, Londonderry, North Ireland
[2] Univ Warwick, Coventry, W Midlands, England
[3] Oxford Brookes Univ, Sch Architecture, Oxford, England
[4] Loughborough Univ Technol, Ctr Renewable Energy Syst Technol, Loughborough, Leics, England
基金
英国工程与自然科学研究理事会;
关键词
Solar absorber; Evacuated flat plate solar collector; Transient heat transfer; COLLECTORS; HEAT; TEMPERATURES; CONVECTION; BEHAVIOR; DESIGN;
D O I
10.1016/j.solener.2018.10.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Creating a vacuum (< 1 Pa) around a solar absorber in a flat plate solar thermal collector can increase efficiency by minimising gaseous conduction and convection between the absorber plate and the glass cover. High performance and architecturally attractive flat plate solar thermal collectors are appealing to building owners and designers for supplying clean and renewable energy cost effectively produced via the facade of the building. This two part paper describes the construction techniques and thermal performance of two vacuum enclosures, fabricated at Ulster University, as prototype components for evacuated flat plate solar collectors. The enclosures were tested at three conditions: 0.0033 Pa, 17 Pa and atmospheric pressure. The first enclosure consisted of two glass panes, sealed to an edge spacer and separated by an array of support pillars on a regular square grid to form a narrow evacuated space. The second enclosure, incorporated an uncooled copper plate to represent a solar thermal absorber. Part 1 of this paper has described the fabrication techniques and compared results from hot-box calorimeter and IR thermography testing of the first enclosure with numerical and analytical predictions. Part 2 describes solar simulator testing of the second enclosure which incorporated an uncooled copper plate. Testing under a solar simulator showed a higher stagnation temperature in the high vacuum test (0.0033 Pa) in comparison with the low vacuum (17 Pa) and atmospheric pressure tests. Curve fitting of a heat transfer model to the transient response data demonstrated that radiation and gas conduction were close to predictions. Simulated results were in close agreement with both the transient response and the steady-state asymptotic plate temperatures.
引用
收藏
页码:1224 / 1236
页数:13
相关论文
共 22 条
[1]   Computation of glass-cover temperatures and top heat loss coefficient of flat-plate solar collectors with double glazing [J].
Akhtar, N. ;
Mullick, S. C. .
ENERGY, 2007, 32 (07) :1067-1074
[2]   Transient test methods for flat-plate collectors: Review and experimental evaluation [J].
Amer, EH ;
Nayak, JK ;
Sharma, GK .
SOLAR ENERGY, 1997, 60 (05) :229-243
[3]   Evaluation of a transient test procedure for solar flat-plate collectors [J].
Amer, EH ;
Nayak, JK .
ENERGY, 1999, 24 (12) :979-995
[4]  
[Anonymous], 2009, ASHRAE Fundamentals 2009
[5]  
[Anonymous], 2011, ARALDITE DATA SHEET
[6]  
Arya F., 2014, THESIS
[7]   USE OF MODERATE VACUUM ENVIRONMENTS AS A MEANS OF INCREASING COLLECTION EFFICIENCIES AND OPERATING TEMPERATURES OF FLAT-PLATE SOLAR COLLECTORS [J].
EATON, CB ;
BLUM, HA .
SOLAR ENERGY, 1975, 17 (03) :151-158
[8]  
Gray W.A., 1974, ENG CALCULATIONS RAD
[9]   FREE CONVECTIVE HEAT-TRANSFER ACROSS INCLINED AIR LAYERS [J].
HOLLANDS, KGT ;
UNNY, TE ;
RAITHBY, GD ;
KONICEK, L .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (02) :189-193
[10]  
Jaffer A., 2011, ONLINE DOCUMENTATION