A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions

被引:90
作者
Al-Ekrish, A. A. [1 ]
Ekram, M. [2 ]
机构
[1] King Saud Univ, Dept Oral Med & Diagnost Sci, Coll Dent, Riyadh 11564, Saudi Arabia
[2] Cairo Univ, Fac Oral & Dent Med, Cairo, Egypt
关键词
beam CT; spiral CT; dental implants; reproducibility of results; FLAT-PANEL IMAGER; CT;
D O I
10.1259/dmfr/27546065
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to investigate the accuracy and reliability of linear measurements of edentulous ridges recorded from 16-row multidetector CT (MDCT) images and cone beam CT (CBCT) images acquired using a flat panel detector (FPD) with a large field of view (FOV), both independently and in comparison with each other. Methods: Edentulous areas of human dry skulls were marked with gutta-percha markers to standardize the plane of the transverse cross-sections and path of measurements. The skulls were imaged using a 16-row MDCT scanner and a CBCT device with a large FOV and a FPD. Ridge dimensions were recorded from reformatted sections by two observers and compared with measurements recorded directly from the bone. The measurement errors and intra and interexaminer reliability were calculated for each modality and compared with each other. Results: The overall mean of the absolute errors was 0.75 mm for MDCT and 0.49 mm for CBCT. The mean of the CBCT absolute errors was smaller than that of the MDCT absolute errors for the overall data, as well as for the site-specific data. The intraexaminer reliability score was 0.994 for MDCT and 0.995 for CBCT. The interexaminer reliability was 0.985 for MDCT and 0.958 for CBCT. Conclusions: Both MDCT and CBCT were associated with a clinically and statistically significant measurement error. CBCT measurements were significantly more accurate than those of MDCT. The measurements recorded from both modalities had a high inter and intraexaminer reliability. Accuracy of measurements was found to be more operator dependent with CBCT than with MDCT. Dentomaxillofacial Radiology (2011) 40, 67-75. doi: 10.1259/dmfr/27546065
引用
收藏
页码:67 / 75
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 2002, The Essential Physics of Medical Imaging
[2]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[3]   Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™):: system configuration and physical properties [J].
Araki, K ;
Maki, K ;
Seki, K ;
Sakamaki, K ;
Harata, Y ;
Sakaino, R ;
Okano, T ;
Seo, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) :51-59
[4]   Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro [J].
Cavalcanti, MGP ;
Haller, JW ;
Vannier, MW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (06) :690-694
[5]   Computed tomography for dental implants: the influence of the gantry angle and mandibular positioning on the bone height and width [J].
Dantas, JA ;
Montebello, A ;
Campos, PSF .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (01) :9-15
[6]  
Fuchs T, 2003, PHYS MEDICA, V19, P153
[7]   Accuracy of cone beam computed tomography in determining the location of the genial tubercle [J].
Hueman, Elizabeth M. ;
Noujeim, Marcel E. ;
Langlais, Robert P. ;
Prihoda, Thomas J. ;
Miller, Frank R. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 137 (01) :115-118
[8]   Cone-beam computed tomography with a flat-panel imager: Initial performance characterization [J].
Jaffray, DA ;
Siewerdsen, JH .
MEDICAL PHYSICS, 2000, 27 (06) :1311-1323
[9]  
Kalender WA, 2003, RADIOLOGE, V43, P379, DOI 10.1007/s00117-003-0897-4
[10]   Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography [J].
Katsumata, Akitoshi ;
Hirukawa, Akiko ;
Okumura, Shinji ;
Naitoh, Munetaka ;
Fujishita, Masami ;
Ariji, Eiichiro ;
Langlais, Robert P. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (06) :829-836