Restricted access media supports for direct high-throughput analysis of biological fluid samples: review of recent applications

被引:31
作者
Cassiano, Neila Maria [1 ]
Barreiro, Juliana Cristina [1 ]
Moraes, Marcela Cristina [1 ]
Oliveira, Regina Vincenzi [1 ]
Cass, Quezia Bezerra [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE MICROEXTRACTION; MOLECULARLY IMPRINTED POLYMER; TANDEM MASS-SPECTROMETRY; HPLC-MS/MS METHOD; MEASURING ENVIRONMENTAL PHENOLS; MONOLITHIC STATIONARY PHASES; MULTIDIMENSIONAL ONLINE SPE; DIRECT-INJECTION ANALYSIS; COLUMN-SWITCHING LC;
D O I
10.4155/BIO.09.39
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review presents an update on the use of restricted-access materials (RAMs) for direct injection of biological samples. The fundamental improvements in the preparation of tailored RAMs and the diversity of applications with these phases are presented. Insights into diminishing the matrix effect by the use of RAM supports in methods by LC-MS and into the low number of methods for enantiomeric separations by direct injections of biological samples are addressed. The diversity of systems that incorporate RAMs for selective sample clean-up or fractionation in proteome and peptidome analysis is also covered.
引用
收藏
页码:577 / 594
页数:18
相关论文
共 142 条
[1]   Feasibility of an on-line restricted access material/liquid chromatography/tandem mass spectrometry method in the rapid and sensitive determination of organophosphorus triesters in human blood plasma [J].
Amini, N ;
Crescenzi, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (02) :245-256
[2]   Reduction of carry-over in column-switching HPLC/MS system with automated system washing procedure for highly sensitive direct analysis of donepezil in dog plasma [J].
Asakawa, Yoshiki ;
Ozawa, Chinami ;
Osada, Katsunobu ;
Kaneko, Shoji ;
Asakawa, Naoki .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (02) :683-690
[3]   Determination of albendazole metabolites by direct injection of bovine plasma and multidimensional achiral-chiral high performance liquid chromatography [J].
Belaz, Katia Roberta A. ;
Cass, Quezia B. ;
Oliveira, Regina V. .
TALANTA, 2008, 76 (01) :146-153
[4]   Determination of bile acids in human serum by on-line restricted access material-ultra high-performance liquid chromatography-mass spectrometry [J].
Bentayeb, K. ;
Batlle, R. ;
Sanchez, C. ;
Nerin, C. ;
Domeno, C. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 869 (1-2) :1-8
[5]   Role of the carbohydrate moieties in chiral recognition on teicoplanin-based LC stationary phases [J].
Berthod, A ;
Chen, XH ;
Kullman, JP ;
Armstrong, DW ;
Gasparrini, F ;
D'Acquarica, I ;
Villani, C ;
Carotti, A .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1767-1780
[6]   Liquid chromatographic determination of enrofloxacin in nasal secretions and plasma of healthy pigs using restricted access material for on-line sample clean-up [J].
Bimazubute, M. A. ;
Rozet, E. ;
Dizier, I. ;
Gustin, P. ;
Hubert, Ph. ;
Crommen, J. ;
Chiap, P. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :456-466
[7]   Liquid chromatography-mass spectrometry as a routine method in forensic sciences: a proof of maturity [J].
Bogusz, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :3-19
[8]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[9]  
2-0
[10]   Direct plasma liquid chromatographic-tandem mass spectrometric analysis of granisetron and its 7-hydroxy metabolite utilizing internal surface reversed-phase guard columns and automated column switching devices [J].
Boppana, VK ;
MillerStein, C ;
Schaefer, WH .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02) :227-236