The effect of modified locking methods and suture materials on Zone II flexor tendon repair-An ex vivo study

被引:9
作者
Yoneda, Susumu [1 ,2 ]
Okubo, Hirotaka [2 ]
Linderman, Stephen W. [1 ]
Kusano, Nozomu [3 ]
Silva, Matthew J. [1 ]
Thomopoulos, Stavros [4 ,5 ]
Kanaya, Fuminori [2 ]
Gelberman, Richard H. [1 ]
机构
[1] Washington Univ, Dept Orthopaed Surg, St Louis, MO 63130 USA
[2] Univ Ryukyus, Grad Sch Med, Dept Orthoped Surg, Okinawa, Japan
[3] Tominaga Kusano Hosp, Dept Orthoped Surg, Niigata, Japan
[4] Columbia Univ, Dept Orthoped Surg, New York, NY USA
[5] Columbia Univ, Dept Biomed Engn, New York, NY USA
来源
PLOS ONE | 2018年 / 13卷 / 10期
基金
美国国家卫生研究院;
关键词
EARLY ACTIVE MOBILIZATION; CORE SUTURE; GLIDING RESISTANCE; GAP FORMATION; STRENGTH; EXCURSION; CADAVER; CANINES; MOTION; LOOPS;
D O I
10.1371/journal.pone.0205121
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The failure rate of intrasynovial tendon repair is high due to substantial elongation at the repair site and to the development of adhesions between the tendon's surface and the surrounding digital sheath. To minimize these complications, we sought to reduce the incidence of gapping and to facilitate the initiation of early motion by improving the time zero structural properties of repair. The Winters-Gelberman 8-strand repair technique was modified by adding surface lock loops and by using Fiberwire suture material. Forty-eight canine flexor digitorum profundus tendons were transected and repaired with one of three 8-strand techniques (Pennington modified Kessler, half hitch loops, or surface locking Kessler) using either 3-0 Supramid or 4-0 Fiberwire suture. Biomechanical testing was performed to determine the physiologic and failure mode properties of the repairs. The surface locking Kessler technique improved repair maximum load, load necessary to create a 2 mm repair site gap, and yield force compared to the modified Kessler and half hitch loop techniques. Fiberwire suture improved maximum load, the load necessary to create a 2 mm repair site gap, stiffness, and yield force compared to Supramid suture. Failure occurred by both suture pull out and by suture breakage in the modified Kessler, Supramid suture repair group. Failure occurred consistently by suture breakage in the surface locking Kessler, Supramid suture repair group. These results reveal that a novel locking Kessler repair is significantly stronger than the current state-of-the art flexor tendon suture repair technique. The use of a surface locking Kessler technique with Fiberwire suture markedly improves the mechanical properties of intrasynovial tendon repair by reducing the risk of post-operative gapping and rupture.
引用
收藏
页数:9
相关论文
共 30 条
  • [11] Causes of Flexor Tendon Repair Failures in Two Common Repair Techniques: A Cadaver Study
    Mistry, Raakhi
    McCleave, Michael John
    Codrington, John
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (03) : 333 - 338
  • [12] Clinical outcomes of early active mobilization following flexor tendon repair using the six-strand technique: short- and long-term evaluations
    Moriya, K.
    Yoshizu, T.
    Maki, Y.
    Tsubokawa, N.
    Narisawa, H.
    Endo, N.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2015, 40 (03) : 250 - 258
  • [13] The effect of core suture flexor tendon repair techniques on gliding resistance during static cycle motion and load to failure: a human cadaver study
    Moriya, T.
    Larson, M. C.
    Zhao, C.
    An, K. -N.
    Amadio, P. C.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (04) : 316 - 322
  • [14] Effect of Core Suture Technique and Type on the Gliding Resistance during Cyclic Motion following Flexor Tendon Repair: A Cadaveric Study
    Moriya, Tamami
    Zhao, Chunfeng
    Yamashita, Toshihiko
    An, Kai-Nan
    Amadio, Peter C.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2010, 28 (11) : 1475 - 1481
  • [15] Intrasynovial flexor tendon repair: A biomechanical study of variations in suture application in human cadavera
    Nelson, Gregory N.
    Potter, Ryan
    Ntouvali, Eleni
    Silva, Matthew J.
    Boyer, Martin I.
    Gelberman, Richard H.
    Thomopoulos, Stavros
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (10) : 1652 - 1659
  • [16] The Effect of Suture Caliber and Number of Core Suture Strands on Zone II Flexor Tendon Repair: A Study in Human Cadavers
    Osei, Daniel A.
    Stepan, Jeffrey G.
    Calfee, Ryan P.
    Thomopoulos, Stavros
    Boyer, Martin I.
    Potter, Ryan
    Gelberman, Richard H.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (02): : 262 - 268
  • [17] Structural Failure Mechanisms of Common Flexor Tendon Repairs
    Peltz, Tim Sebastian
    Haddad, Roger
    Scougall, Peter James
    Nicklin, Sean
    Gianoutsos, Mark Peter
    Oliver, Rema
    Walsh, William Robert
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2015, 20 (03) : 369 - 379
  • [18] LOCKING LOOP TENDON SUTURE
    PENNINGTON, DG
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1979, 63 (05) : 648 - 652
  • [19] Active mobilisation following single cross grasp four-strand flexor tenorrhaphy (Adelaide repair)
    Sandow, M. J.
    McMahon, M.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2011, 36E (06) : 467 - 475
  • [20] FLEXOR TENDON REPAIR USING A 6 STRAND METHOD OF REPAIR AND EARLY ACTIVE MOBILIZATION
    SAVAGE, R
    RISITANO, G
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (04) : 396 - 399