Urine iodide determination by ion-pair reversed-phase high performance liquid chromatography and pulsed amperometric detection

被引:21
作者
Nguyen, Vo Thanh Phuong [1 ]
Piersoel, Virginie [1 ]
El Mahi, Tank [1 ]
机构
[1] Free Univ Brussels, CHU St Pierre, Clin Chem Lab, B-1000 Brussels, Belgium
关键词
Urinary iodide; Iodine deficiency; Ion-pair reversed-phase high performance liquid chromatography; Pulsed amperometric detection (PAD); NEUTRON-ACTIVATION ANALYSIS; SERUM; SILVER; THIOSULFATE; ELECTRODES; HPLC;
D O I
10.1016/j.talanta.2012.06.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and specific ion-pair reversed-phase high performance liquid chromatography (HPLC) method for urinary iodine analysis is described. This method is based on pulsed amperometric detection (PAD) using a silver working electrode (HPLC-PAD), which improves peak shape, electrode stability as well as linearity and reproducibility. A two-step extraction process consisting of solid phase extraction (SPE) and liquid-liquid extraction with dichloromethane was added in order to improve sample purification which is essential with the use of PAD. Treated samples were eluted on a C18 column, using a phosphate buffer containing ion-pairing reagent tetrabutylammonium and 5% MeOH. The calibration standard curves were linear up to 500 mu g/L and within-run and between-run coefficients of variation (CVs) were <6% with the quantification limit fixed at 614/L. Accuracy, expressed as recovery, ranged from 94% to 104%. Comparison with the Technicon AutoAnalyzer acid digestion (AA) method resulted in a high correlation (r=0.9916). Due to a low quantification limit and high sample throughput, the proposed technique appears suitable for both epidemiological and clinical follow-up studies. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 29 条
  • [1] Determination of iodide in urine by ion-pair chromatography with electrochemical detection
    Below, H
    Kahlert, H
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04): : 431 - 436
  • [2] Iodide analysis by anion-exchange chromatography and pulsed amperometric detection in surface water and adsorbable organic iodide
    Bruggink, Cees
    van Rossum, Willem J. M.
    Spijkerman, Ed
    van Beelen, Eric S. E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1144 (02) : 170 - 174
  • [3] Comparison of silver, gold and modified platinum electrodes for the electrochemical detection of iodide in urine samples following ion chromatography
    Cataldi, TRI
    Rubino, A
    Laviola, MC
    Ciriello, R
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (02): : 224 - 231
  • [4] Pulsed amperometric detection of sulfide, cyanide, iodide, thiosulfate, bromide and thiocyanate with microfabricated disposable silver working electrodes in ion chromatography
    Cheng, J
    Jandik, P
    Avdalovic, N
    [J]. ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) : 267 - 274
  • [5] The nutritional iodine supply of Belgian neonates is still insufficient
    Ciardelli, R
    Haumont, D
    Gnat, D
    Vertongen, F
    Delange, F
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2002, 161 (10) : 519 - 523
  • [6] NEUTRON-ACTIVATION ANALYSIS OF IODINE IN BLOOD SERUM OR OTHER BIOLOGICAL-MATERIALS BY SUBSTOICHIOMETRIC PRECIPITATION OF IODINE AS SILVER-IODIDE
    CORNELIS, R
    HOSTE, J
    [J]. JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1973, 13 (02): : 419 - 426
  • [7] CORNELIS R, 1975, ANAL CHIM ACTA, V78, P317, DOI 10.1016/S0003-2670(00)00152-5
  • [8] Silent iodine prophylaxis in Western Europe only partly corrects iodine deficiency; the case of Belgium
    Delange, F
    Van Onderbergen, A
    Shabana, W
    Vandemeulebroucke, E
    Vertongen, F
    Gnat, D
    Dramaix, M
    [J]. EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2000, 143 (02) : 189 - 196
  • [9] Dunn J. T., 1993, METHODS MEASURING IO
  • [10] Fast colorimetric method for measuring urinary iodine
    Gnat, D
    Dunn, AD
    Chaker, S
    Delange, F
    Vertongen, F
    Dunn, JT
    [J]. CLINICAL CHEMISTRY, 2003, 49 (01) : 186 - 188