Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging by Freeze-Spot Deposition of the Matrix

被引:7
作者
Nambiar, Shabarinath [1 ]
Kahn, Nusrat [2 ]
Gummer, Joel P. A. [3 ,4 ]
机构
[1] Murdoch Univ, Sch Vet & Life Sci, Murdoch, WA 6150, Australia
[2] Murdoch Univ, Sch Environm Sci, Murdoch, WA 6150, Australia
[3] Edith Cowan Univ, Sch Sci, Joondalup, WA 6027, Australia
[4] ChemCentre, Bentley, WA 6102, Australia
关键词
MALDI; imaging mass spectrometry; matrix application; freeze-spot; quantitation; TISSUE;
D O I
10.1021/jasms.1c00063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Imaging mass spectrometry has emerged as a powerful metabolite measurement approach to capture the spatial dimension of metabolite distribution in a biological sample. In matrix- assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI), deposition of the chemical-matrix onto the sample serves to simultaneously extract biomolecules to the sample surface and concurrently render the sample amenable to MALDI. However, matrix application may mobilize sample metabolites and will dictate the efficiency of matrix crystallization, together limiting the lateral resolution which may be optimally achieved by MSI. Here, we describe a matrix application technique, herein referred to as the "freeze-spot" method, conceived as a low-cost preparative approach requiring minimal amounts of chemical matrix while maintaining the spatial dimension of sample metabolites for MALDI-MSI. Matrix deposition was achieved by pipette spot application of the matrix-solubilized within a solvent solution with a freezing point above that of a chilled sample stage to which the sample section is mounted. The matrix solution freezes on contact with the sample and the solvent is removed by sublimation, leaving a fine crystalline matrix on the sample surface. Freeze-spotting is quick to perform, found particularly useful for MALDI-MSI of small sample sections, and well suited to efficient and cost-effective method development pipelines, while capable of maintaining the lateral resolution required by MSI.
引用
收藏
页码:1829 / 1836
页数:8
相关论文
共 38 条
[1]   Current State and Future Challenges of Mass Spectrometry Imaging for Clinical Research [J].
Addie, Ruben D. ;
Balluff, Benjamin ;
Bovee, Judith V. M. G. ;
Morreau, Hans ;
McDonnell, Liam A. .
ANALYTICAL CHEMISTRY, 2015, 87 (13) :6426-6433
[2]   Automated acoustic matrix deposition for MALDI sample preparation [J].
Aerni, HR ;
Cornett, DS ;
Caprioli, RM .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :827-834
[3]   Automated MALDI matrix deposition method with inkjet printing for imaging mass spectrometry [J].
Baluya, Dodge L. ;
Garrett, Timothy J. ;
Yost, Richard A. .
ANALYTICAL CHEMISTRY, 2007, 79 (17) :6862-6867
[4]   MALDI Imaging of Lipid Biochemistry in Tissues by Mass Spectrometry [J].
Berry, Karin A. Zemski ;
Hankin, Joseph A. ;
Barkley, Robert M. ;
Spraggins, Jeffrey M. ;
Caprioli, Richard M. ;
Murphy, Robert C. .
CHEMICAL REVIEWS, 2011, 111 (10) :6491-6512
[5]  
Boughton Berin A, 2017, Adv Exp Med Biol, V965, P291, DOI 10.1007/978-3-319-47656-8_12
[6]   Mass spectrometry imaging for plant biology: a review [J].
Boughton, Berin A. ;
Thinagaran, Dinaiz ;
Sarabia, Daniel ;
Bacic, Antony ;
Roessner, Ute .
PHYTOCHEMISTRY REVIEWS, 2016, 15 (03) :445-488
[7]   Improving Tissue Preparation for Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging. Part 1: Using Microspotting [J].
Franck, Julien ;
Arafah, Karim ;
Barnes, Alan ;
Wisztorski, Maxence ;
Salzet, Michel ;
Fournier, Isabelle .
ANALYTICAL CHEMISTRY, 2009, 81 (19) :8193-8202
[8]  
Fukuyama Yuko, 2015, Mass Spectrom (Tokyo), V4, pA0037, DOI 10.5702/massspectrometry.A0037
[9]   Matrix Segregation as the Major Cause for Sample Inhomogeneity in MALDI Dried Droplet Spots [J].
Gabriel, Stefan J. ;
Schwarzinger, Clemens ;
Schwarzinger, Bettina ;
Panne, Ulrich ;
Weidner, Steffen M. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (08) :1356-1363
[10]   Optimization and Comparison of Multiple MALDI Matrix Application Methods for Small Molecule Mass Spectrometric Imaging [J].
Gemperline, Erin ;
Rawson, Stephanie ;
Li, Lingjun .
ANALYTICAL CHEMISTRY, 2014, 86 (20) :10030-10035