Application of contrast-enhanced ultrasound in the diagnosis of burn depth

被引:2
作者
Jiang, Xue [1 ]
Li, Feng [2 ]
Chi, Yunfei [2 ]
Chen, Xin [2 ]
Luo, Yukun [3 ]
Ye, Qinggui [1 ]
Song, Wenjing [1 ]
Li, Guoping [4 ]
机构
[1] Peoples Liberat Army Gen Hosp, Dept Ultrasound Diag, Med Ctr 4, Beijing, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Burns & Plast Dept, Med Ctr 4, Beijing, Peoples R China
[3] Peoples Liberat Army Gen Hosp, Dept Ultrasound Diag, Med Ctr 1, Beijing, Peoples R China
[4] Grand Life Sci & Technol Ltd, Beijing, Peoples R China
关键词
Cutaneous burns; contrast-enhanced ultrasound (CEUS); animal study; pathological diagnosis; DOMAIN IMAGING SFDI; THICKNESS; MODEL; FLOW;
D O I
10.21037/atm-21-3715
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The diagnosis of burn depth often relies on the subjective judgment of plastic surgeons. Contrast-enhanced ultrasound (CEUS) can visualize the microcirculation well and has potential value in diagnosing the depth of burn wounds. We assessed the depth of the burn wounds by CEUS, and compared the results with histological examination. Methods: Two rhesus monkeys were used, and multiple burn wounds with different depths were made on their backs. The echo of the dermis and subcutaneous tissue were observed for each wound, and the thickness of the dermis was measured. CEUS was performed to evaluate the depth of burn wounds and compared with pathological results. Results: (I) After scalding, dermal tissue edema occurred, and the thickness of the dermis measured by a US tended to increase gradually, related to the time of scalding and the order of measurement. (II) With the prolongation of the burn time, the depth of filling by contrast agent gradually increased, from the superficial dermis to the deep dermis and subcutaneous tissue, indicating that the depth of tissue damage gradually increased. This was consistent with the pathological observation. The thickness of the healthy dermis was about 1.3-1.8 mm, and 2.7-4.1 mm after scalding. The depth of the burn wounds was 0.9-4.1 mm, accounting for 32-100% of the full skin thickness. Conclusions: CEUS is a convenient and fast examination method that is consistent with pathological diagnosis of the depth of burn wounds and could prove valuable for the accurate assessment of burn injuries.
引用
收藏
页数:7
相关论文
共 50 条
[21]   Combined Hepatocellular Cholangiocarcinoma (Biphenotypic) Tumors: Potential Role of Contrast-Enhanced Ultrasound in Diagnosis [J].
Li, Fei ;
Han, Jing ;
Han, Feng ;
Wang, Jian-wei ;
Luo, Rong-zhen ;
Li, An-hua ;
Zhou, Jian-hua .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (04) :767-774
[22]   Value of an expanded range of lesions on contrast-enhanced ultrasound for the diagnosis of hypervascular breast masses [J].
Jia, Chao ;
Niu, Qinghua ;
Liu, Long ;
Li, Gang ;
Jin, Lifang ;
Du, Lianfang ;
Shi, Qiusheng ;
Li, Fan .
GLAND SURGERY, 2023, 12 (06) :824-833
[23]   Contrast-Enhanced Ultrasound for differential diagnosis of pancreatic mass lesions: a meta-analysis [J].
Lin, Li Zhou ;
Li, Fan ;
Liu, Yang ;
Xing, Ling Xi ;
Du, Lian Fang .
MEDICAL ULTRASONOGRAPHY, 2016, 18 (02) :163-169
[24]   Intravesical contrast-enhanced ultrasound (CEUS) for the diagnosis of vesicouterine fistula (VUF): A case report [J].
Sun, Fangfang ;
Cui, Lifeng ;
Zhang, Lili ;
Hao, Jianxun ;
Gu, Jinhua ;
Du, Jie ;
Zhao, Lirong .
MEDICINE, 2018, 97 (17)
[25]   Application of ultrasound and contrast-enhanced ultrasound to distinguish salivary focal inflammatory masses from malignant masses: A retrospective observational study [J].
Zhao, Yanan ;
Jiang, Tao ;
Lv, Kun ;
Pan, Minqiang ;
Wen, Qing ;
Huang, Pintong .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 79 (03) :423-434
[26]   Application of contrast-enhanced ultrasonography in the diagnosis of skeletal muscle crush injury in rabbits [J].
Zhang, C-D ;
Lv, F-Q ;
Li, Q-Y ;
Zhang, Y. ;
Shi, X-Q ;
Li, X-Y ;
Tang, J. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041)
[27]   Contrast-enhanced plane-wave ultrasound imaging of the rat eye [J].
Urs, Raksha ;
Ketterling, Jeffrey A. ;
Tezel, Gulgun ;
Silverman, Ronald H. .
EXPERIMENTAL EYE RESEARCH, 2020, 193
[28]   Evaluation of Renal Microcirculation by Contrast-Enhanced Ultrasound With Sonazoid™ as a Contrast Agent [J].
Tsuruoka, Kayori ;
Yasuda, Takashi ;
Koitabashi, Kenichiro ;
Yazawa, Masahiko ;
Shimazaki, Minako ;
Sakurada, Tsutomu ;
Shirai, Sayuri ;
Shibagaki, Yugo ;
Kimura, Kenjiro ;
Tsujimoto, Fumio .
INTERNATIONAL HEART JOURNAL, 2010, 51 (03) :176-182
[29]   Contrast-Enhanced Ultrasound for Assessing Abdominal Conditions in Pregnancy [J].
Geyer, Thomas ;
Rubenthaler, Johannes ;
Froelich, Matthias F. ;
Sabel, Laura ;
Marschner, Constantin ;
Schwarze, Vincent ;
Clevert, Dirk-Andre .
MEDICINA-LITHUANIA, 2020, 56 (12) :1-12
[30]   The Use of Contrast-enhanced Ultrasound in Pediatrics: A Case Series [J].
Cizmarevic, Urban ;
Hanzic, Nina ;
Zerdin, Matija .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (11)