Poly(divinylbenzene-alkyl methacrylate) monolithic stationary phases in capillary electrochromatography

被引:19
作者
Huang, Hsi-Ya [1 ]
Cheng, Yi-Jie
Liu, Wan-Ling
Hsu, Yi-Fen
Lee, Szetsen
机构
[1] Chung Yuan Christian Univ, Dept Chem, Chungli 320, Taiwan
关键词
pi-pi interaction; Polystyrene-based monolithic stationary; phase; Capillary electrochromatography; Alkyl methacrylate; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLVATION ENERGY RELATIONSHIPS; IONIZATION MASS-SPECTROMETRY; PI-PI INTERACTIONS; COLUMNS; CEC; SEPARATION; HPLC; FABRICATION; ACID);
D O I
10.1016/j.chroma.2010.07.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a series of poly(divinylbenzene-alkyl methacrylate) monolithic stationary phases, which were prepared by single step in situ polymerization of divinylbenzene and various alkyl methacry-lates (butyl-, octyl-, or lauryl-methacrylate), were developed as separation columns of benzophenone compounds for capillary electrochromatography (CEC). In addition to the presence of plenty of benzene moieties, the stationary phases contained long and flexible alkyl groups on the surface. With an increase in the molecular length of alkyl methacrylate, the polymeric monolith, which had higher hydrophobicity, effectively reduced the peak tailing of benzophenones, but a weaker retention was observed. The unusual phenomenon was likely due to the pi-pi interaction between the aromatic compound and the polymeric material. The usage of longer alkyl methacrylate as reaction monomer limited the retention of aromatic compounds on the stationary phase surface, thus the pi-pi interaction between them was possibly reduced. Consequently, the retention time of aromatic compounds was markedly decreased with an increase in carbon length of alkyl methacrylate that was carried on the polymeric monolith. Compared to previous reports on polystyrene-based columns in which the peak-tailing problem was reduced by decreasing the benzene moieties on the stationary phase, this study demonstrated that the undesirable retention (peak-tailing) could also be improved by the inclusion of long alkyl methacrylate to the polystyrene-based columns. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:5839 / 5847
页数:9
相关论文
共 35 条
[1]   Chiral stationary phases for HPLC - Choosing the right stationary phase can be daunting. [J].
Armstrong, DW ;
Zhang, B .
ANALYTICAL CHEMISTRY, 2001, 73 (19) :557A-561A
[2]  
Bedair M, 2002, ELECTROPHORESIS, V23, P2938, DOI 10.1002/1522-2683(200209)23:17<2938::AID-ELPS2938>3.0.CO
[3]  
2-8
[4]   Could linear solvation energy relationships give insights into chiral recognition mechanisms?: 1.: π-π and charge interaction in the reversed versus the normal phase mode [J].
Berthod, Alain ;
Mitchell, Clifford R. ;
Armstrong, Daniel W. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1166 (1-2) :61-69
[5]   CEC column behaviour of butyl and lauryl methacrylate monoliths prepared in non-aqueous media [J].
Canto-Mirapeix, Amparo ;
Herrero-Martinez, Jose M. ;
Mongay-Fernandez, Carlos ;
Simo-Alfonso, Ernesto F. .
ELECTROPHORESIS, 2009, 30 (04) :607-615
[6]   Chemical initiation for butyl and lauryl acrylate monolithic columns for CEC [J].
Canto-Mirapeix, Amparo ;
Herrero-Martinez, Jose M. ;
Mongay-Fernandez, Carlos ;
Simo-Alfonso, Ernesto F. .
ELECTROPHORESIS, 2009, 30 (04) :599-606
[7]   Recent progress of polar stationary phases in CEC and capillary liquid chromatography [J].
Dong, Xiaoli ;
Wu, Ren'an ;
Dong, Jing ;
Wu, Minghuo ;
Zhu, Yan ;
Zou, Hanfa .
ELECTROPHORESIS, 2009, 30 (01) :141-154
[8]   Tailoring the morphology of methacrylate ester-based monoliths for optimum efficiency in liquid chromatography [J].
Eeltink, S ;
Herrero-Martinez, JM ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7342-7347
[9]   Recent advances in the control of morphology and surface chemistry of porous polymer-based monolithic stationary phases and their application in CEC [J].
Eeltink, Sebastiaan ;
Svec, Frantisek .
ELECTROPHORESIS, 2007, 28 (1-2) :137-147
[10]   Fabrication of a poly(styrene-octadecene-divinylbenzene) monolithic column and its comparison with a poly(styrene-divinylbenzene) monolithic column for the separation of proteins [J].
Gu, Congying ;
Lin, Li ;
Chen, Xiaodong ;
Jia, Jinping ;
Ren, Jicun ;
Fang, Nenghu .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (07) :1005-1012