PDMS-glass serpentine microchannel chip for time domain PCR with bubble suppression in sample injection

被引:22
作者
Cho, Chul-Ho
Cho, Woong
Ahn, Yoomin
Hwang, Seung-Yong
机构
[1] Samsung Elect Co Ltd, Telecommun R&D Ctr, Suwon 443742, South Korea
[2] Hanyang Univ, Grad Sch, Dept Mech Engn, Seoul 133791, South Korea
[3] Hanyang Univ, Dept Mech Engn, Ansan 426791, South Korea
[4] Hanyang Univ, Div Mol & Life Sci, Ansan 426791, South Korea
关键词
D O I
10.1088/0960-1317/17/9/009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports on the development of a low-cost microreactor ( 10 mu l) biochip for DNA polymerase chain reaction ( PCR). The microbiochip ( 20 mm x 28 mm) is a hybrid type that is composed of a polydimethylsiloxane ( PDMS) layer with a serpentine microchannel ( 360 mu m x 100 mu m) chamber and glass substrate integrated with a microheater and thermal microsensor. Because of the hydrophobic chip surface, bubbles are usually created during sample loading in the PMDS-based microchip. These bubbles disrupt the stable biochemical reaction. An improved microreactor chamber was designed using microfluidic simulation. The reactor has a rounded-corner serpentine channel architecture, which enables stable injection into the hydrophobic surface using only a micropipette. The reactor temperature needed for the PCR reaction is controlled within +/- 0.5 degrees C by the LabVIEW software proportional-integrative-derivative (PID) controller. PCR analyses of the sex-determining Y chromosome (SRY) gene and mouse GAPDH gene were successfully performed in less than 54 min by the fabricated microreactor chip.
引用
收藏
页码:1810 / 1817
页数:8
相关论文
共 25 条
  • [1] Surface modification effect of wettability on the performance of a PDMS-based valveless micropump
    Cho, Woong
    Ko, Yong-Jun
    Ahn, Yoomin
    Yoon, Joon-Yong
    Cho, Nahm Gyoo
    [J]. EXPERIMENTAL MECHANICS IN NANO AND BIOTECHNOLOGY, PTS 1 AND 2, 2006, 326-328 : 297 - +
  • [2] Silicon microchambers for DNA amplification
    Daniel, JH
    Iqbal, S
    Millington, RB
    Moore, DF
    Lowe, CR
    Leslie, DL
    Lee, MA
    Pearce, MJ
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) : 81 - 88
  • [3] Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor
    El-Ali, J
    Perch-Nielsen, IR
    Poulsen, CR
    Bang, DD
    Telleman, P
    Wolff, A
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2004, 110 (1-3) : 3 - 10
  • [4] Biochemical analysis and optimization of inhibition and adsorption phenomena in glass-silicon PCR-chips
    Erill, I
    Campoy, S
    Erill, N
    Barbé, J
    Aguiló, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03): : 685 - 692
  • [5] PDMS-based microfluidic devices for biomedical applications
    Fujii, T
    [J]. MICROELECTRONIC ENGINEERING, 2002, 61-2 : 907 - 914
  • [6] Polymerase chain reaction in polymeric microchips:: DNA amplification in less than 240 seconds
    Giordano, BC
    Ferrance, J
    Swedberg, S
    Hühmer, AFR
    Landers, JP
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 291 (01) : 124 - 132
  • [7] Hong JW, 2001, ELECTROPHORESIS, V22, P328
  • [8] Hsu JT, 1997, BIOTECHNOL BIOENG, V55, P359, DOI 10.1002/(SICI)1097-0290(19970720)55:2<359::AID-BIT13>3.0.CO
  • [9] 2-C
  • [10] Fabrication and characterization of a PDMS-glass hybrid continuous-flow PCR chip
    Kim, JA
    Lee, JY
    Seong, S
    Cha, SH
    Lee, SH
    Kim, JJ
    Park, TH
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2006, 29 (1-2) : 91 - 97