Effect of cataract surgery on retinal nerve fiber layer thickness parameters using scanning laser polarimetry (GDxVCC)

被引:14
作者
Dada, Tanuj [1 ]
Behera, Geeta [1 ]
Agarwal, Anand [1 ]
Kumar, Sanjeev [1 ]
Sihota, Ramanjit [1 ]
Panda, Anita [1 ]
机构
[1] All India Inst Med Sci, Dr Rajendra Prasad Ctr Ophthalm Sci, Glaucoma Res Facil, New Delhi 110029, India
关键词
Birefringence; cataract; glaucoma; scanning laser polarimeter; OPTICAL COHERENCE TOMOGRAPHY; INTRAOCULAR-LENS IMPLANTATION; CAPSULAR OPACIFICATION REMOVAL; OCULAR HYPERTENSION; GLAUCOMA; BIREFRINGENCE; PHACOEMULSIFICATION; EXTRACTION; EYES;
D O I
10.4103/0301-4738.67048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the effect of cataract extraction on the retinal nerve fiber layer (RNFL) thickness, and assessment by scanning laser polarimetry (SLP), with variable corneal compensation (GDx VCC), at the glaucoma service of a tertiary care center in North India. Materials and Methods: Thirty-two eyes of 32 subjects were enrolled in the study. The subjects underwent RNFL analysis by SLP (GDx VCC) before undergoing phacoemulsification cataract extraction with intraocular lens (IOL) implantation (Acrysof SA 60 AT) four weeks following cataract surgery. The RNFL thickness parameters evaluated both before and after surgery included temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and nerve fiber index (NFI). Results: The mean age of subjects was 57.6 +/- 11.7 years (18 males, 14 females). Mean TSNIT average thickness (mu m) pre- and post-cataract surgery was 49.2 +/- 14.1 and 56.5 +/- 7.6 (P = 0.001). There was a statistically significant increase in RNFL thickness parameters (TSNIT average, superior average, and inferior average) and decrease in NFI post-cataract surgery as compared to the baseline values. Mean NFI pre- and post-cataract surgery was 41.3 +/- 15.3 and 21.6 +/- 11.8 (P = 0.001). Conclusions: Measurement of RNFL thickness parameters by scanning laser polarimetry is significantly altered following cataract surgery. Post the cataract surgery, a new baseline needs to be established for assessing the longitudinal follow-up of a glaucoma patient. The presence of cataract may lead to an underestimation of the RNFL thickness, and this should be taken into account when analyzing progression in a glaucoma patient.
引用
收藏
页码:389 / 393
页数:5
相关论文
共 20 条
[1]   BIREFRINGENCE OF THE HUMAN CRYSTALLINE LENS INVIVO [J].
BRINK, HBK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1991, 8 (11) :1788-1793
[2]   Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma [J].
Brusini, Paolo ;
Salvetat, Maria L. ;
Zeppieri, Marco ;
Tosoni, Claudia ;
Parisi, Lucia ;
Felletti, Mirella .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (05) :650-655
[3]  
Chiba Tatsuya, 2000, Nippon Ganka Gakkai Zasshi, V104, P626
[4]  
Collur S, 2000, OPHTHALMIC SURG LAS, V31, P126
[5]   The effect of phacoemulsification cataract surgery on the measurement of retinal nerve fiber layer thickness using optical coherence tomography [J].
El-Ashry, Mohamed ;
Appaswamy, Shivashankar ;
Deokule, Sunil ;
Pagliarini, Sergio .
CURRENT EYE RESEARCH, 2006, 31 (05) :409-413
[6]   The influence of posterior capsular opacification removal on anterior segment birefringence parameters as measured by scanning laser polarimetry [J].
Garcia-Medina, Jose J. ;
Garcia-Medina, Manuel ;
Zanon-Moreno, Vicente C. ;
Gallego-Pinazo, Roberto ;
Pons-Vazquez, Sheila ;
Gonzalez-Ocampo, Samuel ;
Pinazo-Duran, Maria D. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (05) :414-420
[7]   Effect of cataract extraction and intraocular lens implantation on nerve fibre layer thickness measurements by scanning laser polarimeter (GDx) in glaucoma patients [J].
Gazzard, G ;
Foster, PJ ;
Devereux, JG ;
Oen, F ;
Chew, PTK ;
Khaw, PT ;
Seah, SKL .
EYE, 2004, 18 (02) :163-168
[8]   Clear corneal incision of 2.75 mm for cataract surgery induces little change of astigmatism in eyes with low preoperative corneal cylinder [J].
Giansanti, F. ;
Rapizzi, E. ;
Virgili, G. ;
Mencucci, R. ;
Bini, A. ;
Vannozzi, L. ;
Menchini, U. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2006, 16 (03) :385-393
[9]   Comparison of optical coherence tomography and scanning laser polarimetry in glaucoma, ocular hypertension, and suspected glaucoma [J].
Halkiadakis, Oannis ;
Kipioti, Athina ;
Emfietzoglou, Ioannis ;
Grigoropoulos, Vlassis ;
Katsis, Athanasios ;
Alimisi, Sotiria ;
Vergados, Ioannis ;
Theodossiadis, Panagiotis ;
Theodossiadis, George P. .
OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (02) :125-132
[10]   Scanning laser polarimetry of nerve fiber layer thickness in normal eyes after cataract phacoemulsification and foldable intraocular lens implantation [J].
Iacono, P ;
Da Pozzo, S ;
Vattovani, O ;
Tognetto, D ;
Ravalico, G .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :1042-1049