Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents

被引:68
作者
Ang, Hui Ying [1 ]
Huang, Ying Ying [2 ]
Lim, Soo Teik [1 ,3 ]
Wong, Philip [1 ,3 ]
Joner, Michael [4 ]
Foin, Nicolas [1 ]
机构
[1] Natl Heart Ctr Singapore, Singapore, Singapore
[2] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore, Singapore
[3] Duke NUS Med Sch, Singapore, Singapore
[4] Tech Univ Munich, Deutsch Herzzentrum Munchen, Munich, Germany
关键词
Bioresorbable stents; coronary artery disease; coronary stents; bioresorbable scaffolds (BRS); magnesium (Mg) stents; bioresorbable vascular scaffold (BVS); CORONARY-ARTERY-DISEASE; SIROLIMUS-ELUTING STENT; VASCULAR SCAFFOLD; ABSORB II; BIODEGRADABLE METALS; MAGNESIUM; IMPLANTATION; OUTCOMES; DESIGN; BENCH;
D O I
10.21037/jtd.2017.06.30
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Bioresorbable scaffolds (BRS) were developed to overcome the drawbacks of current metallic drug-eluting stents (DES), such as late in-stent restenosis and caging of the vessel permanently. The concept of the BRS is to provide transient support to the vessel during healing before being degraded and resorbed by the body, freeing the vessel and restoring vasomotion. The mechanical properties of the BRS are influenced by the choice of the material and processing methods. Due to insufficient radial strength of the bioresorbable material, BRS often required large strut profile as compared to conventional metallic DES. Having thick struts will in turn affect the deliverability of the device and may cause flow disturbance, thereby increasing the incidence of acute thrombotic events. Currently, the bioresorbable poly-l-lactic acid (PLLA) polymer and magnesium (Mg) alloys are being investigated as materials in BRS technologies. The bioresorption process, mechanical properties, in vitro observations and clinical outcomes of PLLA-based and Mg-based BRS will be examined in this review.
引用
收藏
页码:S923 / S934
页数:12
相关论文
共 64 条
[11]   Bioresorbable vascular scaffold radial expansion and conformation compared to a metallic platform: insights from in vitro expansion in a coronary artery lesion model [J].
Foin, Nicolas ;
Lee, Renick ;
Bourantas, Christos ;
Mattesini, Alessio ;
Soh, Nicole ;
Lim, Jie En ;
Torii, Ryo ;
Ng, Jaryl ;
Liang, Leo Hwa ;
Caiazzo, Gianluca ;
Fabris, Enrico ;
Kilic, Dogu ;
Onuma, Yoshinobu ;
Low, Adrian F. ;
Nijjer, Sukh ;
Sen, Sayan ;
Petraco, Ricardo ;
Al Lamee, Rasha ;
Davies, Justin E. ;
Di Mario, Carlo ;
Wong, Philip ;
Serruys, Patrick W. .
EUROINTERVENTION, 2016, 12 (07) :834-844
[12]   Impact of stent strut design in metallic stents and biodegradable scaffolds [J].
Foin, Nicolas ;
Lee, Renick D. ;
Torii, Ryo ;
Guitierrez-Chico, Juan Luis ;
Mattesini, Alessio ;
Nijjer, Sukhjinder ;
Sen, Sayan ;
Petraco, Ricardo ;
Davies, Justin E. ;
Di Mario, Carlo ;
Joner, Michael ;
Virmani, Renu ;
Wong, Philip .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (03) :800-808
[13]  
Gajjar CR, 2014, SPRINGERBRIEF MATER, P7, DOI 10.1007/978-3-319-08305-6_2
[14]   Bioresorbable Vascular Scaffolds Versus Metallic Stents in Patients With Coronary Artery Disease ABSORB China Trial [J].
Gao, Runlin ;
Yang, Yuejin ;
Han, Yaling ;
Huo, Yong ;
Chen, Jiyan ;
Yu, Bo ;
Su, Xi ;
Li, Lang ;
Kuo, Hai-Chien ;
Ying, Shih-Wa ;
Cheong, Wai-Fung ;
Zhang, Yunlong ;
Su, Xiaolu ;
Xu, Bo ;
Popma, Jeffery J. ;
Stone, Gregg W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) :2298-2309
[15]   Assessing Bioresorbable Coronary Devices Methods and Parameters [J].
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. ;
Campos, Carlos M. ;
Muramatsu, Takashi ;
Nakatani, Shimpei ;
Zhang, Yao-Jun ;
Onuma, Yoshinobu ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (11) :1130-1148
[16]   Coronary Stents Looking Forward [J].
Garg, Scot ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (10) :S43-S78
[17]   Vasomotor Function Comparative Assessment at 1 and 2 Years Following Implantation of the Absorb Everolimus-Eluting Bioresorbable Vascular Scaffold and the Xience V Everolimus-Eluting Metallic Stent in Porcine Coronary Arteries Insights From In Vivo Angiography, Ex Vivo Assessment, and Gene Analysis at the Stented/Scaffolded Segments and the Proximal and Distal Edges [J].
Gogas, Bill D. ;
Benham, James J. ;
Hsu, Steve ;
Sheehy, Alexander ;
Lefer, David J. ;
Goodchild, Traci T. ;
Polhemus, David J. ;
Bouchi, Yasir H. ;
Hung, Olivia Y. ;
Yoo, Sang-Yong ;
Joshi, Udit ;
Giddens, Don P. ;
Veneziani, Alessandro ;
Quyyumi, Arshed ;
Rapoza, Richard ;
King, Spencer B., III ;
Samady, Habib .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07) :728-741
[18]   Absorbable stent: focus on clinical applications and benefits [J].
Gonzalo, Nieves ;
Macaya, Carlos .
VASCULAR HEALTH AND RISK MANAGEMENT, 2012, 8 :125-132
[19]   Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial [J].
Haude, Michael ;
Ince, Hueseyin ;
Abizaid, Alexandre ;
Toelg, Ralph ;
Lemos, Pedro Alves ;
von Birgelen, Clemens ;
Christiansen, Evald Hoj ;
Wijns, William ;
Neumann, Franz-Josef ;
Kaiser, Christoph ;
Eeckhout, Eric ;
Teik Lim, Soo ;
Escaned, Javier ;
Garcia-Garcia, Hector M. ;
Waksman, Ron .
LANCET, 2016, 387 (10013) :31-39
[20]   Degradation Behaviour of Metallic Biomaterials for Degradable Stents [J].
Hermawan, H. ;
Moravej, M. ;
Dube, D. ;
Fiset, M. ;
Mantovani, D. .
THERMEC 2006 SUPPLEMENT: 5TH INTERNATIONAL CONFERENCE ON PROCESSING AND MANUFACTURING OF ADVANCED MATERIALS, 2007, 15-17 :113-118