Biomechanical and allergological characteristics of a biodegradable poly(D,L-lactic acid) coating for orthopaedic implants

被引:51
作者
Gollwitzer, H
Thomas, P
Diehl, P
Steinhauser, E
Summer, B
Barnstorf, S
Gerdesmeyer, L
Mittelmeier, W
Stemberger, A
机构
[1] Tech Univ Munich, Klin & Poliklin Orthopadie & Sportorthopadie, D-81675 Munich, Germany
[2] Berufsgenossenschaftliche Unfallklin Murnau, Abt Sept Chirurg, D-82418 Murnau, Germany
[3] Univ Munich, Klin & Poliklin Dermatol & Allergol, D-80337 Munich, Germany
[4] Univ Rostock, Orthopad Klin & Poliklin, D-18055 Rostock, Germany
[5] Tech Univ Munich, Inst Expt Onkol & Therapieforsch, D-81675 Munich, Germany
关键词
PDLLA; bonding strength; shear strength; T-cell proliferation; nickel allergy;
D O I
10.1016/j.orthres.2005.02.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A poly(D,L-lactic acid) surface coating (PDLLA) has been developed to optimize interactions at the implant-tissue interface. Mechanical and allergological characteristics were evaluated in the present study to elucidate possible indications and limitations prior to clinical application. Implants of stainless steel and Ti-6Al-4V and Co-Cr-Mo alloys were coated with PDLLA, and mechanical stability was studied during intramedullary implantation into rat and human cadaver bones and during dilation of coronary artery stents. Elongation resistance was examined on AlMgSi alloy specimens. Furthermore, proliferation of peripheral blood mononuclear cells of nickel-allergic donors and controls and interleukin-4 and interferon-gamma levels were measured in the presence of coated/uncoated implants and after stimulation with phytohemagglutinin or NiSO4. PDLLA remained stable on the implants with a minimum of 96% of the original coating mass and tolerated lengthening of at least 8%. Further lengthening was followed by microcracking and cohesive failure within the coating. PDLLA exerted no suppressive effect upon spontaneous and pan-T-cell mitogen inducible T-cell proliferation. Furthermore, specific proliferation to nickel in cells of nickel-allergic blood donors and production of interleukin-4 and IFN-gamma were not influenced by the coating. PDLLA coating proved high mechanical stability on different orthopaedic implants and did not influence in vitro T-cell reactivity towards specific biomaterials. (c) 2005 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:802 / 809
页数:8
相关论文
共 31 条
[1]   Inhibition of neointima formation after experimental coronary artery stenting -: A new biodegradable stent coating releasing hirudin and the prostacyclin analogue iloprost [J].
Alt, E ;
Haehnel, I ;
Beilharz, C ;
Prietzel, K ;
Preter, D ;
Stemberger, A ;
Fliedner, T ;
Erhardt, W ;
Schömig, A .
CIRCULATION, 2000, 101 (12) :1453-1458
[2]  
Arm DM, 1997, J BIOMED MATER RES, V35, P433, DOI 10.1002/(SICI)1097-4636(19970615)35:4<433::AID-JBM3>3.0.CO
[3]  
2-I
[4]  
*ASTM, 2001, 6330117 ASTM C
[5]   Influence of insoluble excipients on film coating systems [J].
Felton, LA ;
McGinity, JW .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2002, 28 (03) :225-243
[6]   Physical and biological evaluations of sintered hydroxyapatite/silicone composite with covalent bonding for a percutaneous implant material [J].
Furuzono, T ;
Wang, PL ;
Korematsu, A ;
Miyazaki, K ;
Oido-Mori, M ;
Kowashi, Y ;
Ohura, K ;
Tanaka, J ;
Kishida, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 65B (02) :217-226
[7]   Antibacterial poly(D,L-lactic acid) coating of medical implants using a biodegradable drug delivery technology [J].
Gollwitzer, H ;
Ibrahim, K ;
Meyer, H ;
Mittelmeier, W ;
Busch, R ;
Stemberger, A .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2003, 51 (03) :585-591
[8]  
GOLLWITZER H, 2003, TRAUMA BERUFSKRAN S2, V5, pS347
[9]   BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[10]  
GRISTINA AG, 1994, CLIN ORTHOP RELAT R, P106