Impact of flash glucose monitoring on quality of life and glycaemic control parameters in adults with type 1 diabetes mellitus

被引:0
作者
Jimenez-Sahagun, Rebeca [1 ,2 ]
Gomez Hoyos, Emilia [1 ,2 ]
Diaz Soto, Gonzalo [1 ,2 ]
Nieto de la Marca, Maria de la O. [1 ]
Sanchez Ibanez, Marta [1 ]
del Amo Simon, Sofia [1 ]
Torres Torres, Beatriz [1 ,2 ]
Lopez Gomez, Juan Jose [1 ,2 ]
Delgado Garcia, Esther [1 ,2 ]
Ortola Buigues, Ana [1 ,2 ]
de Luis Roman, Daniel [1 ,2 ]
机构
[1] Hosp Clin Univ Valladolid, Serv Endocrinol & Nutr, Valladolid, Spain
[2] Fac Med, Ctr Invest Endocrinol & Nutr IENVA, Valladolid, Spain
来源
ENDOCRINOLOGIA DIABETES Y NUTRICION | 2022年 / 69卷 / 05期
关键词
Flash glucose monitoring; Type 1 diabetes mellitus; Quality of life; Glycaemic control; Blood glucose self-monitoring; HYPOGLYCEMIA; PEOPLE;
D O I
10.1016/j.endinu.2021.05.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Flash glucose monitoring (FGM) improves some glycaemic control variables and quality of life parameters. Objective: Our aim was to evaluate the quality of life and glycaemic control parameters after initiating FGM in patients with type 1 diabetes (DM1) in clinical practice. Material and methods: A prospective observational study in DM1 patients that started using FGM between June 2019 and April 2020. We analysed their scores on the Diabetes Quality of Life (DQOL) questionnaire, Diabetes Distress Scale (DDS), Diabetes Treatment Satisfaction Questionnaire (DTSQ) and glycaemic control parameters at baseline and 3 months after the FGM onset. Results: We recruited 114 patients, 56% male, mean age 37.2 (standard deviation, SD 12.4), with 18.7 (SD 11.5) years of DM1, 24.6% of which used continuous subcutaneous insulin infusion. Differences were observed (baseline vs. 3 months) in the DTSQ score (22 [15.5-27] vs. 25 [22-28], P < 0.001) and in the DQOL score (88 [74-104] vs. 84 [70-101], P = 0.017) but not in the DDS score. HbA1c was 7.8% (SD 1.3) vs. 7.4% (SD 1.1) (P < 0.001), without improvement in other glycaemic control variables, except for the mean number of hypoglycaemic events/14 days: 14 (SD 9) at baseline vs. 11.5 (SD 7) at 3 months (P < 0.001). Conclusions: The initiation of FGM, combined with a structured educational programme, was associated with improvement in quality of life and patient satisfaction in DM1 patients. An improvement in HbA1c and a reduction in the number of hypoglycaemia events was observed, but not in the rest of glycaemic control parameters. (C) 2021 SEEN y SED. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:345 / 353
页数:9
相关论文
共 30 条
[1]   Assessing Diabetes Distress and Sleep Quality in Young Adults with Type 1 Diabetes Using FreeStyle Libre: A Prospective Cohort Study [J].
Al Hayek, Ayman A. ;
Al Dawish, Mohamed A. .
DIABETES THERAPY, 2020, 11 (07) :1551-1562
[2]   Diabetes Technology: Standards of Medical Care in Diabetes-2020 [J].
American Diabetes Association .
DIABETES CARE, 2020, 43 :S77-S88
[3]   Flash glucose monitoring (FGM): A clinical review on glycaemic outcomes and impact on quality of life [J].
Ang, Eshen ;
Lee, Zong Xuan ;
Moore, Sacha ;
Nana, Melanie .
JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2020, 34 (06)
[4]  
[Anonymous], DIABETES DISTRESS SC
[5]  
[Anonymous], 1994, HDB PSYCHOL DIABETES
[6]   Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial [J].
Bolinder, Jan ;
Antuna, Ramiro ;
Geelhoed-Duijvestijn, Petronella ;
Kroeger, Jens ;
Weitgasser, Raimund .
LANCET, 2016, 388 (10057) :2254-2263
[7]   Quality of Life and Glucose Control After 1 Year of Nationwide Reimbursement of Intermittently Scanned Continuous Glucose Monitoring in Adults Living With Type 1 Diabetes (FUTURE): A Prospective Observational Real-World Cohort Study [J].
Charleer, Sara ;
De Block, Christophe ;
Van Huffel, Liesbeth ;
Broos, Ben ;
Fieuws, Steffen ;
Nobels, Frank ;
Mathieu, Chantal ;
Gillard, Pieter .
DIABETES CARE, 2020, 43 (02) :389-397
[8]  
DCCT Res Grp, 1988, DIABETES CARE, V11, P725
[9]  
Dover Anna R, 2017, J Diabetes Sci Technol, V11, P442, DOI 10.1177/1932296816661560
[10]   Real-world flash glucose monitoring patterns and associations between self-monitoring frequency and glycaemic measures: A European analysis of over 60 million glucose tests [J].
Dunn, Timothy C. ;
Xu, Yongjin ;
Hayter, Gary ;
Ajjan, Ramzi A. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2018, 137 :37-46