Diagnostic Accuracy of Ultrasonography for Rotator Cuff Tears: A Systematic Review and Meta-analysis

被引:26
作者
Farooqi, Ali S. [2 ]
Lee, Alexander [2 ]
Novikov, David [3 ]
Kelly, Ann Marie [4 ]
Li, Xinning [3 ]
Kelly, John D. [2 ]
Parisien, Robert L. [1 ,5 ]
机构
[1] Mt Sinai, Dept Orthopaed Surg & Sports Med, 5 East 98th St, New York, NY 10029 USA
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Boston Univ, Sch Med, Boston, MA 02215 USA
[4] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Philadelphia, PA 19107 USA
[5] Harvard Med Sch, Boston, MA 02115 USA
关键词
diagnostic ultrasound; rotator cuff; diagnostic imaging; systematic review; MRI; SUBSCAPULARIS TEARS; SHOULDER ULTRASOUND; REPAIR; MRI; SONOGRAPHY; MANAGEMENT; DISORDERS; SURGERY; PAIN;
D O I
10.1177/23259671211035106
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: With recent improvements in transducer strength, image resolution, and operator training, ultrasound (US) provides an excellent alternative imaging modality for the diagnosis of rotator cuff tears. Purpose: To evaluate the diagnostic accuracy of US for partial- and full-thickness rotator cuff tears and biceps tendon tears, compare diagnostic values with those of magnetic resonance imaging (MRI) using arthroscopy as the reference standard, assess longitudinal improvements in accuracy, and compare diagnostic values from operators with different training backgrounds. Study Design: Systematic review; Level of evidence, 3. Methods: The PubMed and Cochrane Library databases were systematically searched for full-text journal articles published between January 1, 2010, and April 1, 2020. The inclusion criteria were studies that evaluated the diagnostic accuracy of US for rotator cuff tears or biceps tendon tears utilizing arthroscopy as the reference standard. The exclusion criteria were studies with <10 patients, studies including massive tears without reporting diagnostic data for specific tendons, and studies lacking diagnostic outcome data. Extracted outcomes included diagnostic accuracy, sensitivity, specificity, negative predictive value, and positive predictive value. The mean difference and 95% confidence interval were calculated for both US and MRI diagnostic values, and meta-analysis was conducted using the Mantel-Haenszel random-effects model. Results: In total, 23 eligible studies involving 2054 shoulders were included. US demonstrated a higher median diagnostic accuracy for supraspinatus tendon tears (0.83) and biceps tendon tears (0.93) as compared with subscapularis tendon tears (0.76). US was found to have a higher median accuracy (0.93) for full-thickness supraspinatus tears than partial-thickness tears (0.81). US had superior median sensitivity for partial-thickness supraspinatus tears when performed by radiologists as opposed to surgeons (0.86 vs 0.57). Meta-analysis of the 5 studies comparing US and MRI demonstrated no statistically significant difference in diagnostic sensitivity, specificity, or accuracy for any thickness supraspinatus tears (P = .31-.55), full-thickness tears (P = .63-.97), or partial-thickness tears (P = .13-.81). Conclusion: For experienced operators, US is a highly sensitive and specific diagnostic modality for the diagnosis of supraspinatus tears and demonstrates statistically equivalent capability to MRI in the diagnosis of both full- and partial-thickness rotator cuff tears.
引用
收藏
页数:12
相关论文
共 60 条
  • [1] Evaluation of supraspinatus muscle tears by ultrasonography and magnetic resonance imaging in comparison with surgical findings
    Abd-ElGawad, Ehab A.
    Ibraheem, Mohammed A.
    Fouly, Ezzat H.
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2013, 44 (04) : 829 - 834
  • [2] Accuracy of Preoperative Magnetic Resonance Imaging in Predicting a Subscapularis Tendon Tear Based on Arthroscopy
    Adams, Christopher R.
    Schoolfield, John D.
    Burkhart, Stephen S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (11) : 1427 - 1433
  • [3] The detection of full thickness rotator cuff tears using ultrasound
    Al-Shawi, A.
    Badge, R.
    Bunker, T.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (07): : 889 - 892
  • [4] The Sensitivity of Magnetic Resonance Imaging and Ultrasonography in Detecting Rotator Cuff Tears
    Apostolopoulos, Alexandros P.
    Angelis, Stavros
    Yallapragada, Rahi Kiran
    Khan, Shamsul
    Nadjafi, Jila
    Balfousias, Theodore
    Selvan, Thiyagarajah P.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (05)
  • [5] Ultrasonography of the shoulder
    Bouffard, JA
    Lee, SM
    Dhanju, J
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2000, 21 (03) : 164 - 191
  • [6] Shoulder ultrasonography performed by orthopedic surgeons increases efficiency in diagnosis of rotator cuff tears
    Chiu, Chih-Hao
    Chen, Poyu
    Chen, Alvin Chao-Yu
    Hsu, Kuo-Yao
    Chang, Shih-Sheng
    Chan, Yi-Sheng
    Chen, Yeung-Jen
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [7] Cole Brandi, 2016, Shoulder Elbow, V8, P250, DOI 10.1177/1758573216658800
  • [8] Colvin AC, 2012, J BONE JOINT SURG AM, V94A, P227, DOI [10.2106/JBJS.J.00739, 10.2106/JBJS.J.01886]
  • [9] Cowling P., 2011, SHOULDER ELBOW, V3, P13
  • [10] Day M, 2016, BULL HOSP JT DIS, V74, P207