The measurement of the presampled MTF of a high spatial resolution neutron imaging system

被引:23
作者
Cao, Raymond Lei. [1 ]
Biegalski, Steven R. [1 ]
机构
[1] Univ Texas Austin, Nucl Engn Teaching Lab, Austin, TX 78712 USA
关键词
spatial resolution; presampled MTF; edge method; MCP neutron detector; neutron imaging;
D O I
10.1016/j.nima.2007.08.213
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high spatial resolution neutron imaging device was developed at the Mark II TRIGA reactor at The University of Texas at Austin. As the modulation transfer function (MTF) is recognized as a well-established parameter for evaluation of imaging system resolution, the aliasing associated with digital sampling adds complexity to its measurement. Aliasing is especially problematic when using a high spatial resolution micro-channel plate (MCP) neutron detector that has a pixel grid size similar to that of a CCD array. To compensate for the aliasing an angulated edge method was used to evaluate the neutron imaging facility, overcoming aliasing by obtaining an oversampled edge spread function (ESF). Baseline correction was applied to the ESF to remove the noticeable trends and the LSF was multiplied by Hann window to obtain a smoothed version of presampled MTF. The computing procedure is confirmed by visual inspection of a testing phantom; in addition, it is confirmed by comparison to the MTF measurement of a scintillation screen with a known MTF curve. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:621 / 628
页数:8
相关论文
共 21 条
[1]   Characterization of the image quality in neutron radioscopy [J].
Brunner, J ;
Engelhardt, M ;
Frei, G ;
Gildemeister, A ;
Lehmann, E ;
Hillenbach, A ;
Schillinger, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3) :123-128
[3]   SIGNAL AND NOISE IN MODULATION TRANSFER-FUNCTION DETERMINATIONS USING THE SLIT, WIRE, AND EDGE TECHNIQUES [J].
CUNNINGHAM, IA ;
REID, BK .
MEDICAL PHYSICS, 1992, 19 (04) :1037-1044
[4]  
Dobbins T., 2000, HDB MED IMAGING PHYS, V1, P949
[5]  
EHSAN S, 1998, AAPM, P102
[6]  
FELLER WB, 2000, P HARD XRAY GAMM NEU, V2
[7]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[8]  
GASKILL JD, 1978, LINEAR SYSTEM FOURIE
[9]  
HARRISON H, 1981, RADIOLOGICAL IMAGING
[10]   New neutron imaging facility at the NIST [J].
Hussey, DS ;
Jacobson, DL ;
Arif, M ;
Huffman, PR ;
Williams, RE ;
Cook, JC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 542 (1-3) :9-15