Analysis of wind farm penetration on power swing detection in distance relays

被引:7
作者
Niknezhad, Maryam [1 ]
Sadeh, Javad [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Engn, Dept Elect Engn, Mashhad, Razavi Khorasan, Iran
关键词
PROTECTION; BLOCKING; FAULTS;
D O I
10.1049/rpg2.12333
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Distance protection plays an essential role in the protection of sub-transmission and transmission lines in power systems. However, power swings have occasionally led to the mal-operation of this type of protection. A significant number of large disturbances, such as blackouts, start with power swings. Thus, improving the circumstances leading to this disruptive phenomenon becomes a great priority. Nowadays, the wind power share of worldwide electricity generation and the use of wind farms have increased. As a result, to predict future events, it is necessary to assess the network in the presence of these renewable sources. In this paper, the effects of the wind resources penetration on power swing have been evaluated. Simulations and analyses have been performed in PSCAD/EMTDC and MATLAB environments, respectively. To provide a comprehensive analysis, maximum power passing through the transmission line and power swing frequency have been utilised as criteria. The results show that wind farms presented acceptable behaviour in the presence of power swing and instability. Therefore, in view point of a power swing, induction generator based wind power plants, compared to synchronous generators, led to better overall conditions. Finally, the effect of fixed and variable speed wind turbines on power swing is compared.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 31 条
[1]   Modeling Protection Systems in Time-Domain Simulations: A New Method to Detect Mis-Operating Relays for Unstable Power Swings [J].
Abdi-Khorsand, Mojdeh ;
Vittal, Vijay .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (04) :2790-2798
[2]  
Benmouyal G., 2004, 31st Annual Western Protective Relay Conference, P19
[3]   Distance relay with out-of-step-blocking function using wavelet transform [J].
Brahma, Sukumar M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) :1360-1366
[4]   An Approach for Out-of-Step Protection Based on Swing Center Voltage Estimation and Analytic Geometry Parameters [J].
Camarillo-Penaranda, Juan R. ;
Celeita, David ;
Gutierrez, Mario ;
Toro, Mateo ;
Ramos, Gustavo .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (03) :2402-2408
[5]  
CHAI T, 2014, P IMECHE D, P1
[6]   Fast Identification of Symmetrical or Asymmetrical Faults During Power Swings with Dual Use Line Relays [J].
Chatterjee, Soumesh ;
Roy, Biman Kumar Saha .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2020, 6 (01) :184-192
[7]  
Chung P. D, 2013, International Journal of Advanced Science and Technology, V51, P135
[8]   Phase-space-based symmetrical fault detection during power swing [J].
Dubey, Rahul ;
Samantaray, Subhransu Ranjan ;
Panigrahi, Bijay Ketan ;
Venkoparao, Vijendran G. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (08) :1947-1956
[9]  
Gao Z. D., 1991, APSCOM-91. 1991 International Conference on Advances in Power System Control, Operation and Management (Conf. Publ. No.348), P843
[10]   Current-Based Out-of-Step Detection Method to Enhance Line Differential Protection [J].
Hashemi, Sayyed Mohammad ;
Sanaye-Pasand, Majid .
IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (02) :448-456