Computer simulations of an irrigated radiofrequency cardiac ablation catheter and experimental validation by infrared imaging

被引:5
|
作者
Rossmann, Christian [1 ,2 ]
Motamarry, Anjan [1 ,3 ,4 ]
Panescu, Dorin [5 ]
Haemmerich, Dieter [1 ,6 ]
机构
[1] Med Univ South Carolina, Dept Pediat, Charleston, SC 29425 USA
[2] AdditiveLab, Leuven, Belgium
[3] Med Univ South Carolina, Dept Drug Discovery & Biomed Sci, Charleston, SC 29425 USA
[4] Harvard Univ, Wellman Ctr Photomed, Massachusetts Gen Hosp, Boston, MA 02115 USA
[5] Biotronik, Santa Clara, CA USA
[6] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
基金
美国国家卫生研究院;
关键词
Radiofrequency; microwave; thermal ablation; cardiac catheter ablation; modeling (i; e; heat transfer; ultrasound; EM; integrated; treatment planning); PULSATILE BLOOD-FLOW; DIELECTRIC-PROPERTIES; THERMAL-CONDUCTIVITY; BIOLOGICAL TISSUES; LESION SIZE; BIOPHYSICS; ESTIMATOR; LOCATIONS; ISOTHERM; MODEL;
D O I
10.1080/02656736.2021.1961027
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To develop and validate a three-dimensional (3-D) computer model based on accurate geometry of an irrigated cardiac radiofrequency (RF) ablation catheter with microwave radiometry capability, and to test catheter performance. Methods A computer model was developed based on CAD geometry of a RF cardiac ablation catheter prototype to simulate electromagnetic heating, heat transfer, and computational fluid dynamics (blood flow, open irrigation, and natural convection). Parametric studies were performed; blood flow velocity (0-25 cm/s) and irrigation flow (0-40 ml/min) varied, both with perpendicular (PE) and parallel (PA) catheter orientations relative to tissue. Tissue Agar phantom studies were performed under similar conditions, and temperature maps were recorded via infrared camera. Computer model simulations were performed with constant voltage and with voltage adjusted to achieve maximum tissue temperatures of 95-105 degrees C. Results Model predicted thermal lesion width at 5 W power was 5.8-6.4 mm (PE)/6.5-6.6 mm (PA), and lesion depth was 4.0-4.3 mm (PE)/4.0-4.1 mm (PA). Compared to phantom studies, the mean errors of the computer model were as follows: 6.2 degrees C(PE)/4.3 degrees C (PA) for maximum gel temperature, 0.7 mm (10.9%) (PE)/0.1 mm (0.8%) (PA) for lesion width, and 0.3 mm (7.7%)(PE)/0.7 mm (19.1%) (PA) for lesion depth. For temperature-controlled ablation, model predicted thermal lesion width was 7-9.2 mm (PE)/8.6-9.2 mm (PA), and lesion depth was 4.3-5.5 mm (PE)/3.4-5.4 mm (PA). Conclusions Computer models were able to reproduce device performance and to enable device evaluation under varying conditions. Temperature controlled ablation of irrigated catheters enables optimal tissue temperatures independent of patient-specific conditions such as blood flow.
引用
收藏
页码:1149 / 1163
页数:15
相关论文
共 50 条
  • [1] Experimental measurement of microwave ablation heating pattern and comparison to computer simulations
    Deshazer, Garron
    Prakash, Punit
    Merck, Derek
    Haemmerich, Dieter
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2017, 33 (01) : 74 - 82
  • [2] Rapid Linear Ventricular Ablation Using a Novel Irrigated Multipolar Radiofrequency Ablation Catheter
    Nazer, Babak
    Walters, Tomos E.
    Duggirala, Srikant
    Gerstenfeld, Edward P.
    CIRCULATION, 2016, 134
  • [3] Impact of electrode tip shape on catheter performance in cardiac radiofrequency ablation
    Petras, Argyrios
    Moreno Weidmann, Zoraida
    Echeverria Ferrero, Marina
    Leoni, Massimiliano
    Guerra, Jose M.
    Gerardo-Giorda, Luca
    HEART RHYTHM O2, 2022, 3 (06): : 699 - 705
  • [4] Ablation with an internally irrigated radiofrequency catheter: Learning how to avoid steam pops
    Cooper, JM
    Sapp, JL
    Tedrow, U
    Pellegrini, CP
    Robinson, D
    Epstein, LM
    Stevenson, WG
    HEART RHYTHM, 2004, 1 (03) : 329 - 333
  • [5] Comparative Study of Lesions Obtained through Radiofrequency between the Irrigated Ablation Catheter with a Flexible Tip and the Non-Irrigated Catheter in Ex Vivo Porcine Hearts
    Vitali, Francesco
    De Raffele, Martina
    Malagu, Michele
    Balla, Cristina
    Azzolini, Giorgia
    Gibiino, Federico
    Boccadoro, Alberto
    Micillo, Marco
    Bertini, Matteo
    BIOLOGY-BASEL, 2024, 13 (02):
  • [6] Clinical Impact of an Open-Irrigated Radiofrequency Catheter with Direct Force Measurement on Atrial Fibrillation Ablation
    Martinek, Martin
    Lemes, Christine
    Sigmund, Elisabeth
    Derndorfer, Michael
    Aichinger, Josef
    Winter, Siegmund
    Nesser, Hans-Joachim
    Puererfellner, Helmut
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (11): : 1312 - 1318
  • [7] Computer modeling of radiofrequency cardiac ablation: 30 years of bioengineering research
    Gonzalez-Suarez, Ana
    Perez, Juan J.
    Irastorza, Ramiro M.
    D'Avila, Andre
    Berjano, Enrique
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 214
  • [8] Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation
    Yamane, T
    Jaïs, P
    Shah, DC
    Hocini, M
    Peng, JT
    Deisenhofer, I
    Clémenty, J
    Haïssaguerre, M
    CIRCULATION, 2000, 102 (21) : 2565 - 2568
  • [9] Direct imaging of transvenous radiofrequency cardiac ablation using a steerable fiberoptic infrared endoscope
    Knight, BP
    Burke, MC
    Hong, TE
    McAuley, A
    Amundson, D
    Hanlin, J
    Blankenship, L
    Ferguson, TB
    Nazarian, S
    Berger, RD
    HEART RHYTHM, 2005, 2 (10) : 1116 - 1121
  • [10] SIMULATION OF CARDIAC RADIOFREQUENCY CATHETER ABLATION - THE IMPORTANCE OF WORKING ANGLE
    Jest, T.
    Haber, T.
    Haertig, J.
    Melichercik, J.
    Ismer, B.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58