Measuring Activated Clotting Time during Cardiac Catheterization and PCI: The Effect of the Sampling Site

被引:2
作者
Heemelaar, J. C. [1 ]
Berkhout, T. [1 ]
Heestermans, A. A. C. M. [1 ]
Zant, J. C. [2 ]
de Vos, A. M. J. [3 ]
Verouden, N. J. W. [4 ]
Dirksen, M. T. [1 ]
van Ramshorst, J. [1 ]
机构
[1] Northwest Clin, Dept Cardiol, Alkmaar, Netherlands
[2] Northwest Clin, Dept Clin Chem, Alkmaar, Netherlands
[3] Catharina Hosp, Dept Cardiol, Eindhoven, Netherlands
[4] Amsterdam Univ Med Ctr, Dept Cardiol, Amsterdam, Netherlands
关键词
MYOCARDIAL-INFARCTION; ST-ELEVATION; EXTRACORPOREAL-CIRCULATION; COAGULATION TIME; HEPARIN-THERAPY; ESC GUIDELINES; CORONARY; ARTERIAL; MANAGEMENT;
D O I
10.1155/2021/4091289
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Purpose. We aimed to investigate the influence of the sampling site on the variability of ACT measurement. Activated clotting time (ACT) has been used for decades in cardiac surgery and interventional cardiology to assess unfractionated heparin activity. However, standardized protocols for the use of ACT measurement in the catheterization laboratory are lacking. Methods/Materials. After elective cardiac catheterization, ACT measurements were collected in simultaneously obtained blood samples from three different sample sites: the arterial catheter, arterial sheath, and peripheral intravenous line. Measurements were performed using the i-Stat (R) device (Abbott, Princeton, NJ, USA). The study was conducted with approval of the local medical ethical committee. Results. In 100 patients (mean age 67.1, 65% male), no significant differences were observed in ACT values obtained from the guiding catheter and arterial sheath (mean difference (MD) -18.3 s; standard deviation (SD) 96 s; P = 0.067). Contrarily, ACT values obtained from the intravenous line were significantly lower as compared to values obtained from the guiding catheter (MD 25.7 s; SD 75.5; P = 0.003) and arterial sheath (MD 39 s; SD 102.8; P <0.001). Furthermore, ACT measurements from the arterial sheath showed a statistically significant proportional bias when compared to the other sampling sites (sheath vs. catheter, r = 0.761, P = 0.001; sheath vs. IVL, r = 1.013, P < 0.001). Conclusions. The present study shows statistical significance and possibly clinically relevant variations between ACT measurements from different sample sites. Bias in ACT measurements may be minimized by using uniform protocols for ACT measurement during cardiac catheterization.
引用
收藏
页数:6
相关论文
共 17 条
  • [1] Amsterdam EA, 2014, CIRCULATION, V130, pE344, DOI [10.1016/j.jacc.2014.10.011, 10.1016/j.jacc.2014.09.017, 10.1161/CIR.0000000000000134, 10.1016/j.jacc.2014.09.016]
  • [2] In-Hospital Major Bleeding and Its Clinical Relevance in Patients With ST Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention
    Boden, Helen
    Velders, Matthijs A.
    van der Hoeven, Bas L.
    Cannegieter, Suzanne C.
    Scholij, Martin J.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (10) : 1533 - 1539
  • [3] Improving clinical outcomes by reducing bleeding in patients with non-ST-elevation acute coronary syndromes
    Budaj, Andrzej
    Eikelboom, John W.
    Mehta, Shamir R.
    Afzal, Rizwan
    Chrolavicius, Susan
    Bassand, Jean-Pierre
    Fox, Keith A. A.
    Wallentin, Lars
    Peters, Ron J. G.
    Granger, Christopher B.
    Joyner, Campbell D.
    Yusuf, Salim
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (06) : 655 - 661
  • [4] BULL BS, 1975, J THORAC CARDIOV SUR, V69, P685
  • [5] BULL BS, 1975, J THORAC CARDIOV SUR, V69, P674
  • [6] Chew DP, 2001, CIRCULATION, V103, P961
  • [7] Risk profile and benefits from Gp IIb-IIIa inhibitors among patients with ST-segment elevation myocardial infarction treated with primary angioplasty: a meta-regression analysis of randomized trials
    De Luca, Giuseppe
    Navarese, Eliano
    Marino, Paolo
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 (22) : 2705 - 2713
  • [8] Unfractionated heparin and low-molecular-weight heparin in acute coronary syndrome without St elevation: a meta-analysis
    Eikelboom, JW
    Anand, SS
    Malmberg, K
    Weitz, JI
    Ginsberg, JS
    Yusuf, S
    [J]. LANCET, 2000, 355 (9219) : 1936 - 1942
  • [9] RELATION BETWEEN PROCEDURAL ACTIVATED COAGULATION TIME AND OUTCOME AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    FERGUSON, JJ
    DOUGHERTY, KG
    GAOS, CM
    BUSH, HS
    MARSH, KC
    LEACHMAN, DR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) : 1061 - 1065
  • [10] Differences in arterial and venous thromboelastography parameters: Potential roles of shear stress and oxygen content
    Frumento, RJ
    Hirsh, AL
    Parides, MK
    Bennett-Guerrero, E
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (05) : 551 - 554