Repetitive Controller of Capacitor-Less Current-Fed Dual-Half-Bridge Converter for Grid-Connected Fuel Cell System

被引:36
作者
Han, Byeongcheol [1 ]
Bai, Changkyu [1 ]
Lee, Jin S. [1 ]
Kim, Minsung [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Creat IT Engn, Pohang 37673, South Korea
基金
新加坡国家研究基金会;
关键词
DC-link voltage ripple; input current ripple; phase-lead compensator; two control inputs; two-stage inverter; FREQUENCY CURRENT RIPPLE; PHASE-LEAD COMPENSATION; LEARNING CONTROL; REDUCTION; INVERTER; DESIGN;
D O I
10.1109/TIE.2018.2804898
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a repetitive controller (RC) for a capacitor-less current-fed dual-half-bridge (CF-DHB) converter for a grid-connected fuel cell system. The pulsating power caused by the ac grid makes the dc-link voltage and input current fluctuate with twice the grid frequency. To achieve zero-voltage-switching (ZVS) for the capacitor-less CF-DHB converter and to increase the lifetime of the fuel cell, we need to suppress the low-frequency dc-link voltage ripple and the low-frequency input current ripple. We first make use of the duty cycle to regulate the dc-link voltage, and of the phase-shift angle to regulate the input current. Because the transfer function from the duty cycle to the dc-link voltage has a right-half plane (RHP) zero, the conventional proportional-integral controller cannot achieve satisfactory performance at the dc-link voltage. To compensate for the phase lag due to the existence of the RHP zero, we propose to use an RC with phase-lead compensation for dc-link voltage control. Because the transfer function from the phase-shift angle to the input current has one left-half plane zero, the conventional RC is used to control the input current. In developing the proposed controller, we first derive the dynamic model of the CF-DHB converter in the grid-connected environment, and then use the model to design an RC. We also provide a detailed and practical design guideline to select the control parameters of the capacitor-less CF-DHB converter that can meet the desired performance. The proposed RC can reduce the input current ripple significantly and suppress the dc-link voltage ripple within the predetermined range and thereby achieves ZVS. Experimental results demonstrate that the proposed control scheme achieves desirable performance.
引用
收藏
页码:7841 / 7855
页数:15
相关论文
共 34 条
[1]   Low-frequency current ripple reduction in front-end boost converter with single-phase inverter load [J].
Ahmad, A. Ale ;
Abrishamifar, A. ;
Samadi, S. .
IET POWER ELECTRONICS, 2012, 5 (09) :1676-1683
[2]   Design and Analysis of Discrete-Time Repetitive Control for Scanning Probe Microscopes [J].
Aridogan, Ugur ;
Shan, Yingfeng ;
Leang, Kam K. .
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2009, 131 (06) :1-12
[3]  
Bai C, 2017, APPL POWER ELECT CO, P2015, DOI 10.1109/APEC.2017.7930976
[4]   Frequency-Adaptive Filtering of Low-Frequency Harmonic Current in Fuel Cell Power Conditioning Systems [J].
Cao, L. ;
Loo, K. H. ;
Lai, Y. M. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (04) :1966-1978
[5]  
Castro R., 2015, P INT S DYN VEH ROAD, P595
[6]   Digital Plug-In Repetitive Controller for Single-Phase Bridgeless PFC Converters [J].
Cho, Younghoon ;
Lai, Jih-Sheng .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) :165-175
[7]  
EG& G Technical Service Inc, 2004, FUEL CELL HDB
[8]  
Franklin G. F., 1997, DIGITAL CONTROL DYNA, V3
[9]   Input Current-Ripple Consideration for the Pulse-link DC-AC Converter for Fuel Cells by Small Series LC Circuit [J].
Fukushima, Kentaro ;
Norigoe, Isami ;
Shoyama, Masahito ;
Ninomiya, Tamotsu ;
Harada, Yosuke ;
Tsukakoshi, Kenta .
APEC: 2009 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1- 4, 2009, :447-+
[10]   Swinging Bus Operation of Inverters for Fuel Cell Applications With Small DC-Link Capacitance [J].
Galvez, Juan M. ;
Ordonez, Martin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) :1064-1075