Accuracy of ultrasound imaging of the rotator cuff in shoulders that are painful postoperatively

被引:151
作者
Prickett, WD [1 ]
Teefey, SA [1 ]
Galatz, LM [1 ]
Calfee, RP [1 ]
Middleton, WD [1 ]
Yamaguchi, K [1 ]
机构
[1] Washington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, Shoulder & Elbow Serv, St Louis, MO 63110 USA
关键词
D O I
10.2106/00004623-200306000-00016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Evaluation of the rotator cuff in a shoulder that has been persistently painful postoperatively could be challenging. Magnetic resonance imaging has been the preferred imaging method, but accuracy rates have been lower for those shoulders than for shoulders that have not been operated on; also, magnetic resonance imaging is susceptible to suture anchor artifact. The purpose of this study was to evaluate the diagnostic accuracy of ultrasound for evaluating the rotator cuff in shoulders that are painful postoperatively. Methods: The records of forty-four consecutive patients who had undergone both a high-resolution ultrasound examination and subsequent shoulder arthroscopy were retrospectively reviewed. Thirty-four patients underwent rotator cuff repair at the time of the arthroscopy, and ten had subacromial decompression or another procedure without cuff repair. The results of the ultrasound examination were compared with the intraoperative findings of the arthroscopic examination (the "gold standard"). Results: Ultrasound led to a correct diagnosis for forty of the forty-four patients. Twenty-two recurrent rotator cuff tears and twenty-two intact rotator cuffs were found at surgery. Ultrasound correctly identified twenty of the twenty-two rotator cuff tears (true-positive results) and twenty of the twenty-two intact rotator cuffs (true-negative results). Two intact cuffs were identified as having a full-thickness tear (false-positive results), and two cuffs with a full-thickness rotator cuff tear were identified as being intact (false-negative results). The sensitivity and specificity of ultrasound for identifying rotator cuff integrity postoperatively were 91% and 86%, respectively. The accuracy was 89%. Conclusions: Ultrasound is a highly accurate imaging study for evaluating the integrity of the rotator cuff in shoulders that have undergone an operation. Its accuracy for operatively treated shoulders appears to be comparable with that previously reported for shoulders that had not been operated on. Level of Evidence: Diagnostic study, Level II-1 (development of diagnostic criteria on basis of consecutive patients [with universally applied reference "gold" standard]). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1084 / 1089
页数:6
相关论文
共 20 条
[1]  
BOOKER DJ, 1993, CLIN ORTHOP RELAT R, V294, P103
[2]   EARLY ASSESSMENT OF SUPRASPINATUS TEARS - PROCAINE INFILTRATION AS A GUIDE TO TREATMENT [J].
BROWN, JT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1949, 31 (03) :423-425
[3]   ARTHROGRAPHY OF THE SHOULDER AFTER OPERATIVE REPAIR OF THE TORN ROTATOR CUFF [J].
CALVERT, PT ;
PACKER, NP ;
STOKER, DJ ;
BAYLEY, JIL ;
KESSEL, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (01) :147-150
[4]  
CLARK JM, 1992, J BONE JOINT SURG AM, V74, P13
[5]   Functional morphology of the supraspinatus tendon [J].
Fallon, J ;
Blevins, FT ;
Vogel, K ;
Trotter, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (05) :920-926
[6]   Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff - Relationship to operative findings [J].
Gaenslen, ES ;
Satterlee, CC ;
Hinson, GW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1391-1396
[7]  
HAWKINS RH, 1995, CLIN ORTHOP RELAT R, P178
[8]  
Haygood T M, 1993, Magn Reson Imaging Clin N Am, V1, P143
[9]  
ITOI E, 1992, CLIN ORTHOP RELAT R, P165
[10]  
Longobardi R S, 1997, Magn Reson Imaging Clin N Am, V5, P841