The Exploration of a Novel Biodegradable Drug-Eluting Biliary Stent: Preliminary Work

被引:9
作者
Zeng, Chu-Hui [1 ]
Liu, Lin-Lin [1 ]
Zhu, Hai-Dong [1 ]
Teng, Gao-Jun [1 ]
机构
[1] Southeast Univ, Ctr Intervent Radiol & Vasc Surg, Zhongda Hosp, Dept Radiol,Sch Med, 87 Dingjiaqiao Rd, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
Biodegradable; Drug-eluting; Paclitaxel; Poly(lactic-co-glycolic acid); Stent; STRICTURES; FEASIBILITY; PACLITAXEL; MANAGEMENT; PLGA;
D O I
10.1007/s00270-021-02892-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To explore the degradation, drug release, and mechanical properties of drug-incorporated films made of different ratios of poly(lactic-co-glycolic acid) (PLGA) and different amounts of paclitaxel (PTX), which may serve as the material platform for the manufacturing of biodegradable drug-eluting biliary stents. Materials and Methods PLGA of different lactic acid/glycolic acid ratios (50/50, 70/30, and 80/20) and 0%, 10, 20, and 30% weight by weight (w/w) PTX was mixed to make PLGA films, which were then cut into small pieces for further testing. Films were immersed in phosphate-buffered saline (pH 7.4) for a maximum of 11 weeks. Samples were taken randomly at Day 2, 4, 6, 8, 10, 12, 14, and weekly thereafter until Week 11 to test tensile strength, weight loss, pH value of the soaking solution, and drug release. The morphology of films was observed using scanning electron microscope (SEM). Results At Week 10 of degradation, PLGA 80/20 still withstood a tensile strength of 9.7 newton (N), while PLGA 50/50 and 70/30 cracked spontaneously since Day 4. At Week 11, weight loss of PLGA 50/50, 70/30, and 80/20 was 95.15, 82.32, and 16.17%, respectively; and the lowest pH value of soaking solution was 1.87, 1.95, and 6.58, respectively. Drug release of 10, 20, and 30% PTX groups was 3.52-4.48%, 1.90-2.26%, and 1.44-2.06%, respectively. SEM proved smooth films before degradation; however, after the tensile strength was lost, cracks could be seen. Conclusion The degradation rate of PLGA can be controlled by altering lactic acid/glycolic acid ratio. Overall, PLGA 50/50 and 70/30 degrade significantly faster than 80/20. PLGA can serve as an effective drug carrier for PTX while being the stent strut, and PTX can be slowly released as PLGA degrades.
引用
收藏
页码:1633 / 1642
页数:10
相关论文
共 31 条
[11]   Endoscopic therapy of benign biliary strictures [J].
Judah, Joel R. ;
Draganov, Peter V. .
WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (26) :3531-3539
[12]   Risk of Death Following Application of Paclitaxel-Coated Balloons and Stents in the Femoropopliteal Artery of the Leg: A Systematic Review and Meta-Analysis of Randomized Controlled Trials [J].
Katsanos, Konstantinos ;
Spiliopoulos, Stavros ;
Kitrou, Panagiotis ;
Krokidis, Miltiadis ;
Karnabatidis, Dimitrios .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2018, 7 (24)
[13]   Bile leak following living donor liver transplantation: Clinical efficacy of percutaneous transhepatic treatment [J].
Kim, Jin Hyoung ;
Ko, Gi-Young ;
Sung, Kyu-Bo ;
Yoon, Hyun-Ki ;
Gwon, Dong Il ;
Kim, Kyung Rae ;
Lee, Sung-Gyu .
LIVER TRANSPLANTATION, 2008, 14 (08) :1142-1149
[14]   Interventional radiology in the management of benign biliary stenoses, biliary leaks and fistulas: A pictorial review [J].
Krokidis M. ;
Orgera G. ;
Rossi M. ;
Matteoli M. ;
Hatzidakis A. .
Insights into Imaging, 2013, 4 (1) :77-84
[15]   A novel biodegradable biliary stent in the endoscopic treatment of cystic-duct leakage after cholecystectomy [J].
Laukkarinen, Johanna ;
Nordback, Isto ;
Mikkonen, Joonas ;
Kaerkkaeinen, Paeivi ;
Sand, Juhani .
GASTROINTESTINAL ENDOSCOPY, 2007, 65 (07) :1063-1068
[16]   Histologic influence of paclitaxel-eluting covered metallic stents in a canine biliary model [J].
Lee, Sang Soo ;
Shin, Ji Hoon ;
Han, Ji Min ;
Cho, Chang Ho ;
Kim, Myung-Hwan ;
Lee, Sung-Koo ;
Kim, Jin-Hyoung ;
Kim, Kyung-Rae ;
Shin, Kyoung Min ;
Won, Yong Hyun ;
Song, Ho-Young .
GASTROINTESTINAL ENDOSCOPY, 2009, 69 (06) :1140-1147
[17]   METALLIC STENTS IN BENIGN BILIARY STRICTURES - 3-YEAR FOLLOW-UP [J].
MACCIONI, F ;
ROSSI, M ;
SALVATORI, FM ;
RICCI, P ;
BEZZI, M ;
ROSSI, P .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (06) :360-366
[18]   Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier [J].
Makadia, Hirenkumar K. ;
Siegel, Steven J. .
POLYMERS, 2011, 3 (03) :1377-1397
[19]   Benign biliary strictures refractory to standard bilioplasty treated using polydoxanone biodegradable biliary stents: retrospective multicentric data analysis on 107 patients [J].
Mauri, Giovanni ;
Michelozzi, Caterina ;
Melchiorre, Fabio ;
Poretti, Dario ;
Pedicini, Vittorio ;
Salvetti, Monica ;
Criado, Eva ;
Falco Fages, Joan ;
Angel De Gregorio, Miguel ;
Laborda, Alicia ;
Sonfienza, Luca Maria ;
Cornalba, Gianpaolo ;
Monfardini, Lorenzo ;
Panek, Jiri ;
Andrasina, Tomas ;
Gimenez, Mariano .
EUROPEAN RADIOLOGY, 2016, 26 (11) :4057-4063
[20]   Study of biodegradable and self-expandable PLLA helical biliary stent in vivo and in vitro [J].
Meng, Bo ;
Wang, Jing ;
Zhu, Ning ;
Meng, Qing-Yuan ;
Cui, Fu-Zhai ;
Xu, Ying-Xin .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2006, 17 (07) :611-617