Near-Infrared Spectra in Buccal Tissue as a Marker for Detection of Hypoxia

被引:3
|
作者
Amini, Maryam
Hisdal, Jonny
Gjovaag, Terje
Kapetanovic, Nihad
Strand, Trond-Eirik
Owe, Jan Ove
Horthe, John Ragnar
Mirtaheri, Peyman
机构
[1] Oslo & Akershus Univ Coll Appl Sci, Oslo, Norway
[2] Norwegian Armed Forces Med Serv, Inst Aviat Med, Oslo, Norway
[3] Oslo Univ Hosp, Oslo, Norway
关键词
hypobaric chamber; near infrared spectroscopy; synchronization; multivariate calibration; BLOOD-FLOW; OXYGEN-SATURATION; SPECTROSCOPY; CONSUMPTION; PRESSURE; OXIMETRY;
D O I
10.3357/AMHP.4510.2016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
INTRODUCTION: Hypoxia caused by high altitude exposure can impair cerebral and mental functions. Blood flow and oxygenation of the buccal tissue can be reliable markers to detect hypoxia. In this study, near infrared spectroscopy was used in combination with a novel optical probe to evaluate the applicability of the novel probe in measuring hypoxia markers in buccal tissue under a hypoxic condition. METHODS: Six healthy participants were tested at altitudes from 2000 to 16,000 ft inside a hypobaric chamber. The buccal reference measurements of blood flow and oxygen saturation were synchronized with the spectral measurements of the novel near infrared probe and the relationship between the reference measurements and spectral data were evaluated by multivariate partial least square method. In addition, finger oxygen saturation was measured during the experiment and the recordings were compared with buccal oxygen saturation. RESULTS: The spectral analysis illustrated that the spectral data from the near infrared probe correlated strongly with the absorption features of both buccal flow and oxygenation measured by the reflectance sensors (average R-2 = 0.89).The results showed probably overestimated values for buccal oxygen saturation recorded by the reference pulse oximeter in comparison with finger oxygen saturation, with the mean difference increasing from 1.8% at 2000 ft to 11.4% at 16,000 ft. CONCLUSION: The novel near infrared probe showed promising results for simultaneous measurement of blood flow and oxygen saturation in the buccal tissue. The suggested method can be used as a new technique for early indication of hypoxia in future clinical applications.
引用
收藏
页码:498 / 504
页数:7
相关论文
共 50 条
  • [41] A new near-infrared spectroscopy parameter as marker for patients with migraine
    Viola, S.
    Viola, P.
    Litterio, P.
    Buongarzone, M. P.
    Fiorelli, L.
    NEUROLOGICAL SCIENCES, 2013, 34 (01) : S129 - S131
  • [42] Effect of Mars analogue dust deposition on the automated detection of calcite in visible/near-infrared spectra
    Gilmore, MS
    Merrill, MD
    Castaño, R
    Bornstein, B
    Greenwood, JP
    ICARUS, 2004, 172 (02) : 641 - 646
  • [43] Measurement of the liver tissue oxygenation by near-infrared spectroscopy
    Gunnar Naulaers
    Bart Meyns
    Marc Miserez
    Veerle Leunens
    Sabine Van Huffel
    Paul Casaer
    Hugo Devlieger
    Intensive Care Medicine, 2005, 31 : 138 - 141
  • [44] Measurement of the liver tissue oxygenation by near-infrared spectroscopy
    Naulaers, G
    Meyns, B
    Miserez, M
    Leunens, V
    Van Huffel, S
    Casaer, P
    Devlieger, H
    INTENSIVE CARE MEDICINE, 2005, 31 (01) : 138 - 141
  • [45] Cardiac tissue characterization using near-infrared spectroscopy
    Moon, Rajinder Singh
    Hendon, Christine P.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [46] STUDIES ON SPECTRA-STRUCTURE CORRELATIONS IN NEAR-INFRARED SPECTRA OF PROTEINS AND POLYPEPTIDES .1. A MARKER BAND FOR HYDROGEN-BONDS
    LIU, YL
    CHO, RK
    SAKURAI, K
    MIURA, T
    OZAKI, Y
    APPLIED SPECTROSCOPY, 1994, 48 (10) : 1249 - 1254
  • [47] Effects and Detection of Raw Material Variability on the Performance of Near-Infrared Calibration Models for Pharmaceutical Products
    Igne, Benoit
    Shi, Zhenqi
    Drennen, James K., III
    Anderson, Carl A.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 103 (02) : 545 - 556
  • [48] Signal-to-Noise Contribution of Principal Component Loads in Reconstructed Near-Infrared Raman Tissue Spectra
    Grimbergen, M. C. M.
    van Swol, C. F. P.
    Kendall, C.
    Verdaasdonk, R. M.
    Stone, N.
    Bosch, J. L. H. R.
    APPLIED SPECTROSCOPY, 2010, 64 (01) : 8 - 14
  • [49] Data fusion of near-infrared and mid-infrared spectra for identification of rhubarb
    Sun, Wenjuan
    Zhang, Xin
    Zhang, Zhuoyong
    Zhu, Ruohua
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 171 : 72 - 79
  • [50] On mimicking diffuse reflectance spectra in the visible and near-infrared ranges for tissue-like phantom design
    Debernardi, N.
    Dunias, P.
    van El, B.
    Statham, A. E.
    DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE VI, 2014, 8945