Study of thick CZT detectors for X-ray and Gamma-ray astronomy

被引:27
作者
Li, Qiang [1 ,2 ]
Beilicke, M. [2 ]
Lee, Kuen [2 ]
Garson, Alfred, III [2 ]
Guo, Q. [2 ]
Martin, Jerrad [2 ]
Yin, Y. [2 ]
Dowkontt, P. [2 ]
De Geronimo, G. [3 ]
Jung, I. [4 ]
Krawczynski, H. [2 ]
机构
[1] NW Polytech Univ, State Key Lab Solidificat Proc, Sch Mat Sci & Engn, Xian 710072, Peoples R China
[2] Washington Univ, St Louis, MO 63130 USA
[3] Brookhaven Natl Lab, Upton, NY 11973 USA
[4] Univ Erlangen Nurnberg, Erlangen, Germany
关键词
CdZnTe; X-ray and Gamma-ray; CDZNTE DETECTORS; CMOS; PERFORMANCE; IMAGER;
D O I
10.1016/j.astropartphys.2011.01.013
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
CdZnTe (CZT) is a wide bandgap II-VI semiconductor developed for the spectroscopic detection of X-rays and gamma-rays at room temperature. The Swift Burst Alert Telescope is using an 5240 cm(2) array of 2 mm thick CZT detectors for the detection of 15-150 key X-rays from Gamma-ray Bursts. We report on the systematic tests of thicker ( >= 0.5 cm) CZT detectors with volumes between 2 cm(3) and 4 cm(3) which are potential detector choices for a number of future X-ray telescopes that operate in the 10 keV to a few MeV energy range. The detectors contacted in our laboratory achieve Full Width Half Maximum energy resolutions of 2.7 key (4.5%) at 59 keV, 3 keV (2.5%) at 122 key and 4 key (0.6%) at 662 keV. The 59 keV and 122 keV energy resolutions are among the world-best results for >= 0.5 cm thick CZT detectors. We use the data set to study trends of how the energy resolution depends on the detector thickness and on the pixel pitch. Unfortunately, we do not find clear trends, indicating that even for the extremely good energy resolutions reported here, the achievable energy resolutions are largely determined by the properties of individual crystals. Somewhat surprisingly, we achieve the reported results without applying a correction of the anode signals for the depth of the interaction. Measuring the interaction depths thus does not seem to be a pre-requisite for achieving sub-1% energy resolutions at 662 keV. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:769 / 777
页数:9
相关论文
共 50 条
  • [1] Effects of Chemomechanical Polishing on CdZnTe X-ray and Gamma-Ray Detectors
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Gul, Rubi
    James, Ralph B.
    JOURNAL OF ELECTRONIC MATERIALS, 2015, 44 (09) : 3194 - 3201
  • [2] Effects of Chemical Treatments on CdZnTe X-Ray and Gamma-Ray Detectors
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Egarievwe, Alexander A.
    Jones, Dominique E.
    Roy, Utpal N.
    James, Ralph B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (02) : 1091 - 1098
  • [3] Simulation studies of CZT detectors as gamma-ray calorimeter
    Jung, I.
    Krawczynski, H.
    Komarov, S.
    Sobotka, L.
    ASTROPARTICLE PHYSICS, 2006, 26 (02) : 119 - 128
  • [4] Effects of Chemomechanical Polishing on CdZnTe X-ray and Gamma-Ray Detectors
    Stephen U. Egarievwe
    Anwar Hossain
    Ifechukwude O. Okwechime
    Rubi Gul
    Ralph B. James
    Journal of Electronic Materials, 2015, 44 : 3194 - 3201
  • [5] Characterization and evaluation of extended defects in CZT crystals for gamma-ray detectors
    Bolotnikov, A. E.
    Camarda, G. S.
    Cui, Y.
    Yang, G.
    Hossain, A.
    Kim, K.
    James, R. B.
    JOURNAL OF CRYSTAL GROWTH, 2013, 379 : 46 - 56
  • [6] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    Stahle, CM
    Parker, BH
    Parsons, AM
    Barbier, LM
    Barthelmy, SD
    Gehrels, NA
    Palmer, DM
    Snodgrass, SJ
    Tueller, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) : 138 - 145
  • [7] All-sky X-ray & gamma-ray astronomy monitor (AXGAM)
    Tumer, TO
    ONeill, TJ
    Hurley, K
    Ogelman, H
    Paulos, RJ
    Puetter, RC
    Kipnis, I
    Hamilton, WJ
    Proctor, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 572 - 576
  • [8] Characteristics and Stability of Diode Type CdTe-based X-Ray and Gamma-Ray Detectors
    Gnatyuk, V. A.
    Vlasenko, O. I.
    Aoki, T.
    Koike, A.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [9] The X-ray response of CdZnTe detectors to be used as future spectroscopic detectors for X-ray astronomy
    Kraft, S
    Bavdaz, M
    Castelletto, B
    Peacock, A
    Scholze, F
    Ulm, G
    Gagliardi, MA
    Nenonen, S
    Tuomi, T
    Juvonen, M
    Rantamaki, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3) : 337 - 347
  • [10] Dynamics of native oxide growth on CdTe and CdZnTe X-ray and gamma-ray detectors
    Zazvorka, Jakub
    Franc, Jan
    Beran, Lukas
    Moravec, Pavel
    Pekarek, Jakub
    Veis, Martin
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2016, 17 (01) : 792 - 798