A surface-acoustic-wave-based cantilever bio-sensor

被引:15
作者
De Simoni, Giorgio [1 ]
Signore, Giovanni [1 ]
Agostini, Matteo [1 ,2 ]
Beltram, Fabio [2 ]
Piazza, Vincenzo [1 ]
机构
[1] Ist Italian Tecnol, Ctr Nanotechnol Innovat NEST, I-56127 Pisa, Italy
[2] Scuola Normale Super Pisa, NEST, I-56127 Pisa, Italy
关键词
Cantilever bio-sensor; Surface acoustic wave; NANOMECHANICAL DETECTION; MICROCANTILEVER; BINDING; NANOPARTICLE; ASSAY;
D O I
10.1016/j.bios.2014.12.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A scalable surface-acoustic-wave- (SAW-) based cantilevered device for portable bio-chemical sensing applications is presented. Even in the current, proof-of-principle implementation this architecture is shown to outperform commercial quartz-crystal microbalances in terms of sensitivity. Adhesion of analytes on a functionalized surface of the cantilever shifts the resonant frequency of a SAW-generating transducer due to the stress-induced variation of the speed of surface acoustic modes. We discuss the relevance of this approach for diagnostics applications based on miniaturized devices. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:570 / 576
页数:7
相关论文
共 34 条
[1]   Label-free protein assay based on a nanomechanical cantilever array [J].
Arntz, Y ;
Seelig, JD ;
Lang, HP ;
Zhang, J ;
Hunziker, P ;
Ramseyer, JP ;
Meyer, E ;
Hegner, M ;
Gerber, C .
NANOTECHNOLOGY, 2003, 14 (01) :86-90
[2]   A cantilever array-based artificial nose [J].
Baller, MK ;
Lang, HP ;
Fritz, J ;
Gerber, C ;
Gimzewski, JK ;
Drechsler, U ;
Rothuizen, H ;
Despont, M ;
Vettiger, P ;
Battiston, FM ;
Ramseyer, JP ;
Fornaro, P ;
Meyer, E ;
Güntherodt, HJ .
ULTRAMICROSCOPY, 2000, 82 (1-4) :1-9
[3]   PHOTOTHERMAL SPECTROSCOPY WITH FEMTOJOULE SENSITIVITY USING A MICROMECHANICAL DEVICE [J].
BARNES, JR ;
STEPHENSON, RJ ;
WELLAND, ME ;
GERBER, C ;
GIMZEWSKI, JK .
NATURE, 1994, 372 (6501) :79-81
[4]   Thermal analysis using a micromechanical calorimeter [J].
Berger, R ;
Gerber, C ;
Gimzewski, JK ;
Meyer, E ;
Guntherodt, HJ .
APPLIED PHYSICS LETTERS, 1996, 69 (01) :40-42
[5]   Carlo Crivelli [J].
Campbell, Caroline .
ART HISTORY, 2007, 30 (01) :126-U16
[6]  
Cole P. H., 1972, ELECT SURVEILLANCE S
[7]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[8]   Cantilever biosensors [J].
Fritz, Juergen .
ANALYST, 2008, 133 (07) :855-863
[9]  
Gilda N. A., 2011, 2011 International SoC Design Conference (ISOCC 2011), P325, DOI 10.1109/ISOCC.2011.6138776
[10]   Single virus particle mass detection using microresonators with nanoscale thickness [J].
Gupta, A ;
Akin, D ;
Bashir, R .
APPLIED PHYSICS LETTERS, 2004, 84 (11) :1976-1978