Physical, Chemical, and Microbiological Water Quality Variation between City and Building and within Multistory Building

被引:10
作者
Richard, Rain [1 ,3 ]
Hamilton, Kerry A. [1 ,2 ]
Westerhoff, Paul [1 ]
Boyer, Treavor H. [1 ,3 ]
机构
[1] Arizona State Univ, Sch Sustainable Engn & Built Environm SSEBE, Tempe, AZ 85287 USA
[2] Arizona State Univ, Biodesign Ctr Environm Hlth Engn, Tempe, AZ 85287 USA
[3] Arizona State Univ, Biodesign Swette Ctr Environm Biotechnol, Tempe, AZ 85287 USA
来源
ACS ES&T WATER | 2021年 / 1卷 / 06期
关键词
building occupancy; cellular adenosine triphosphate (cATP); chlorine; copper; premise plumbing; trihalomethanes; DRINKING-WATER; NONTUBERCULOUS MYCOBACTERIA; COPPER; CHLORINE; IMPACT; CHLORAMINE; REACTIVITY; CORROSION; RELEASE; DESIGN;
D O I
10.1021/acsestwater.0c00240
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Municipal drinking water entering buildings can experience degraded water quality due to in-building water treatment devices, plumbing design, materials, and occupancy patterns. To understand water quality patterns, we installed online sensors and collected grab samples throughout a multistory university building to quantify temporal and spatial fluctuations in temperature, pH, free chlorine, dissolved copper, trihalomethanes (THMs), cellular adenosine triphosphate (cATP), and organic matter surrogate (UV254). A whole-building water softener had a detrimental impact on water quality, increasing pH, decreasing disinfectant residual, and increasing THMs. Disinfectant residual was always greatest at the building inlet, with little to no measurable free chlorine at sinks and water fountains. Cellular adenosine triphosphate levels were lowest at the building inlet and measured greater at water fountains. Copper levels were <0.2 mg/L entering the building but ranged from 0.5 to 1.5 mg/L within the building. HVAC operations resulted in less variability for in-building water temperature than at the water treatment plant with temperatures averaging 5 degrees C warmer inside the building than at the building inlet. Trihalomethane concentrations were influenced by chlorine residual, pH, and water demand, with consistently higher in-building measurements than at the building inlet. Trihalomethane speciation remained constant throughout the study with chloroform being the greatest contributor to speciation, followed by dichlorobromoform, dibromochloromethane, and finally bromoform.
引用
收藏
页码:1369 / 1379
页数:11
相关论文
共 41 条
[1]  
Amy G.I., 1998, Empirically Based Models for Predicting Chlorination and Ozonation By-Product: Haloacetic Acids, Chloral Hydrate, and Bromate
[2]   Copper as a biocidal tool [J].
Borkow, G ;
Gabbay, J .
CURRENT MEDICINAL CHEMISTRY, 2005, 12 (18) :2163-2175
[3]   Role of temperature, chlorine, and organic matter in copper corrosion by-product release in soft water [J].
Boulay, N ;
Edwards, M .
WATER RESEARCH, 2001, 35 (03) :683-690
[5]   PREVALENCE OF NONTUBERCULOUS MYCOBACTERIA IN WATER-SUPPLIES OF HEMODIALYSIS CENTERS [J].
CARSON, LA ;
BLAND, LA ;
CUSICK, LB ;
FAVERO, MS ;
BOLAN, GA ;
REINGOLD, AL ;
GOOD, RC .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1988, 54 (12) :3122-3125
[6]  
CARSON LA, 1978, APPL ENVIRON MICROB, V36, P839, DOI 10.1128/AEM.36.6.839-846.1978
[7]  
Carter JA, 2019, J BRAZIL CHEM SOC, V30, P462
[8]  
Council N. R., 1980, DRINK WAT HLTH, V2
[9]   Impact of water stagnation in residential cold and hot water plumbing on concentrations of trihalomethanes and haloacetic acids [J].
Dion-Fortier, Annick ;
Rodriguez, Manuel J. ;
Serodes, Jean ;
Proulx, Francois .
WATER RESEARCH, 2009, 43 (12) :3057-3066
[10]   Sampling in schools and large institutional buildings: Implications for regulations, exposure and management of lead and copper [J].
Dore, Evelyne ;
Deshommes, Elise ;
Andrews, Robert C. ;
Nour, Shokoufeh ;
Prevost, Michele .
WATER RESEARCH, 2018, 140 :110-122