Biometric Parameters in Different Stages of Primary Angle Closure Using Low-Coherence Interferometry

被引:5
|
作者
Yazdani, Shahin [1 ]
Akbarian, Shadi [1 ]
Pakravan, Mohammad [1 ]
Doozandeh, Azadeh [1 ]
Afrouzifar, Mohsen [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Tehran, Iran
关键词
biometric parameters; primary angle closure; low-coherence interferometry; ANTERIOR-CHAMBER DEPTH; OCULAR BIOMETRY; LENS THICKNESS; AXIAL LENGTH; GLAUCOMA; DIMENSIONS; POPULATION; SUBTYPES; DEVICE; EYES;
D O I
10.1097/OPX.0000000000000483
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare ocular biometric parameters using low-coherence interferometry among siblings affected with different degrees of primary angle closure (PAC). Methods. In this cross-sectional comparative study, a total of 170 eyes of 86 siblings from 47 families underwent low-coherence interferometry (LenStar 900; Haag-Streit, Koeniz, Switzerland) to determine central corneal thickness, anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), vitreous depth, and axial length (AL). Regression coefficients were applied to show the trend of the measured variables in different stages of angle closure. To evaluate the discriminative power of the parameters, receiver operating characteristic curves were used. Best cutoff points were selected based on the Youden index. Sensitivity, specificity, positive and negative predicative values, positive and negative likelihood ratios, and diagnostic accuracy were determined for each variable. Results. All biometric parameters changed significantly from normal eyes to PAC suspects, PAC, and PAC glaucoma; there was a significant stepwise decrease in central corneal thickness, ACD, AD, vitreous depth, and AL, and an increase in LT and LT/AL. Anterior chamber depth and AD had the best diagnostic power for detecting angle closure; best levels of sensitivity and specificity were obtained with cutoff values of 3.11 mm for ACD and 2.57 mm for AD. Conclusions. Biometric parameters measured by low-coherence interferometry demonstrated a significant and stepwise change among eyes affected with various degrees of angle closure. Although the current classification scheme for angle closure is based on anatomical features, it has excellent correlation with biometric parameters.
引用
收藏
页码:343 / 349
页数:7
相关论文
共 50 条
  • [1] The biometric study in different stages of primary angle-closure glaucoma
    Y-Y Chen
    Y-Y Chen
    S-J Sheu
    P Chou
    Eye, 2013, 27 : 1070 - 1076
  • [2] The biometric study in different stages of primary angle-closure glaucoma
    Chen, Y-Y
    Chen, Y-Y
    Sheu, S-J
    Chou, P.
    EYE, 2013, 27 (09) : 1070 - 1076
  • [3] Scanning system for angle-resolved low-coherence interferometry
    Steelman, Zachary A.
    Ho, Derek
    Chu, Kengyeh K.
    Wax, Adam
    OPTICS LETTERS, 2017, 42 (22) : 4581 - 4584
  • [4] Measuring characteristics and parameters of optical fibers using low-coherence spectral interferometry
    Hlubina, P
    INTERFEROMETRY '99: TECHNIQUES AND TECHNOLOGIES, 1999, 3744 : 441 - 451
  • [5] Cellular organization and substructure measured using angle-resolved low-coherence interferometry
    Wax, A
    Yang, CH
    Backman, V
    Badizadegan, K
    Boone, CW
    Dasari, RR
    Feld, MS
    BIOPHYSICAL JOURNAL, 2002, 82 (04) : 2256 - 2264
  • [6] Correlations Between Anterior Segment Optical Coherence Tomography Parameters in Different Stages of Primary Angle Closure Disease
    Shan, Jing
    Pardeshi, Anmol Anand
    Varma, Rohit
    Xu, Benjamin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [7] Low-coherence interferometry with synthesis of coherence function
    Teramura, Yuichi
    Suzuki, Keiichi
    Suzuki, Masayuki
    Kannari, Fumihiko
    Applied Optics, 1999, 38 (28): : 5974 - 5980
  • [8] Low-Coherence Shearing Interferometry With Constant Off-Axis Angle
    Guo, Rongli
    Barnea, Itay
    Shaked, Natan T.
    FRONTIERS IN PHYSICS, 2021, 8 (08):
  • [9] Low-coherence interferometry with synthesis of coherence function
    Teramura, Y
    Suzuki, K
    Suzuki, M
    Kannari, F
    APPLIED OPTICS, 1999, 38 (28) : 5974 - 5980
  • [10] Agreement in Biometric Parameters Between Swept-Source-Optical Coherence Tomography and Optical Low-Coherence Interferometry: Insights into Clinical Precision
    Munteanu, Mihnea
    Al Barri, Leila
    Stanca, Simona
    Mocanu, Valeria
    Rosca, Cosmin
    Balica, Nicolae-Constantin
    Stanca, Horia T.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)