Geometry calibration of an on-board kV imaging system

被引:4
|
作者
Jeung, A [1 ]
Sloutsky, A [1 ]
Virshup, G [1 ]
Gaudio, S [1 ]
Mostafavi, H [1 ]
Munro, P [1 ]
机构
[1] Varian Med Syst Inc, Palo Alto, CA USA
关键词
D O I
10.1118/1.1998531
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We have developed a method of geometrically calibrating the MV and kV radiographic isocenters of a Varian linear accelerator equipped with an on‐board kV imaging system. Method and Materials: The calibration uses a cylindrical phantom containing 16 BB's placed in a spiral pattern and ∼400–600 radiographs of the phantom acquired using both kV and MV imaging systems. Since the phantom has a known geometry, the 7 degrees of freedom (DOF) needed to fit the predicted projections of the BB's to the measured projections can be calculated. During MV imaging a partial transmission plate is placed in the accelerator wedge slot to project a reference shape onto the EPID images of the phantom. The reference shape accounts for motion of the EPID and generates the radiographic isocenter for the MV x‐ray beam alone. Geometry correction parameters can be calculated for the kV imaging system that map the center of radiographic images or CBCT projections to the radiographic isocenter of the MV beam. The method has been tested with linear accelerator and lab bench imaging systems. Results: BB identification accuracy is ∼0.3 pixels and is limited by noise in the images. While the method is insensitive to changes in SID (0.3 pixels ∼= 2.5 cm SID change), the method can measure known in‐plane imager displacements to an accuracy of better than 0.1 mm. Imager displacements versus gantry angle are small − 0.75×0.50 mm. CBCT reconstruction using parameters from this method results in spatial frequencies as high as 18 lp/cm and adjustments in parameters of ±0.1 mm reduce the reconstructed spatial resolution. Conclusion: Our method to match MV and kV radiographic isocenters for on‐board imaging systems shows that accelerator flex is quite modest but that the calibration method can improve the spatial resolution of the CBCT reconstructions. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2129 / 2130
页数:2
相关论文
共 50 条
  • [1] Entrance exposures during on-board KV imaging
    Kress, A. T.
    Santanam, L.
    Klein, E.
    MEDICAL PHYSICS, 2006, 33 (06) : 1997 - 1997
  • [2] The on-board calibration system of the X-ray Imaging Polarimetry Explorer (XIPE)
    Zane, Silvia
    Winter, Berend
    Theobald, Craig
    Theodorou, Theodorus
    Pinchera, Michele
    Muleri, Fabio
    Spada, Francesca
    Sgro, Carmelo
    Zanetti, Davide
    Feng, Hua
    del Monte, Ettore
    Rubini, Alda
    Soffitta, Paolo
    Bellazzini, Ronaldo
    Bozzo, Enrico
    Burwitz, Vadim
    Castro Tirado, Alberto J.
    Costa, Enrico
    Gburek, Szymon
    Goosmann, Rene
    Karas, Vladimir
    Matt, Giorgio
    Nandra, Kirpal
    Pearce, Mark
    Poutanen, Juri
    Reglero, Victor
    Dolores Sabau, Maria
    Santangelo, Andrea
    Tagliaferri, Giampiero
    Tenzer, Christopher
    Vink, Jacco
    Weisskopf, Martin
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [3] The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) on-board blackbody calibration system
    Best, FA
    Revercomb, HE
    Knuteson, RO
    Tobin, DC
    Ellington, SD
    Werner, MW
    Adler, DP
    Garcia, RK
    Taylor, JK
    Ciganovich, NN
    Smith, WL
    Bingham, GE
    Elwell, JD
    Scott, DK
    MULTISPECTRAL AND HYPERSPECTRAL REMOTE SENSING INSTRUMENTS AND APPLICATIONS II, 2005, 5655 : 77 - 87
  • [4] Calibration and test of the Athena On-board Metrology system
    Abreu, Manuel
    Cabra, Alexandre
    Rebordao, Jose
    Goncalves, Nuno M.
    Mottini, Sergio
    Pinto, Joao Costa
    Santos, Miguel
    Oddenino, Davide
    SPACE TELESCOPES AND INSTRUMENTATION 2024: ULTRAVIOLET TO GAMMA RAY, PT 1, 2024, 13093
  • [5] Stability Analysis of On-Board Calibration System of Spatially Modulated Imaging Fourier Transform Spectrometer
    Gao Jing
    Ji Zhong-ying
    Wang Zhong-hou
    Cui Yan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (04) : 1013 - 1017
  • [6] On-Board Spectral Calibration for Chinese Medium Resolution Imaging Spectrometer
    Fu, R. M.
    Liu, Y. X.
    Li, M.
    3RD INTERNATIONAL SYMPOSIUM OF SPACE OPTICAL INSTRUMENTS AND APPLICATIONS, 2017, 192 : 201 - 209
  • [7] Correction of couch artifacts in KV cone-beam CT from an on-board imaging system
    Ali, I.
    Lovelock, D.
    Kriminski, S.
    Chang, J.
    Amols, H.
    Ali, I.
    MEDICAL PHYSICS, 2006, 33 (06) : 2280 - 2280
  • [8] Imaging dose on a dual on-board kV X-ray imaging system in MHI-TM2000
    Takayama, K.
    Nagano, K.
    Kaneko, S.
    Nakayama, H.
    Kawada, N.
    Takahashi, K.
    Narita, Y.
    Mizowaki, T.
    Kokubo, M.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S655 - S656
  • [9] ASTER on-board calibration status
    Sakuma, F
    Ono, A
    Kudoh, M
    Inada, H
    Akagi, S
    Ohmae, H
    SENSORS, SYSTEMS AND NEXT-GENERATION SATELLITES VI, 2003, 4881 : 407 - 418
  • [10] On-board calibration status of ASTER
    Sakuma, Fumihiro
    Sato, Takashi
    Inada, Hitomi
    Akagi, Shigeki
    Ono, Hidehiko
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES X, 2006, 6361