Initial Clinical Experience Treating Patients with Breast Cancer on a 6-MV Flattening-Filter-Free O-Ring Linear Accelerator

被引:20
作者
Barsky, Andrew R. [1 ]
O'Grady, Fionnbarr [1 ]
Kennedy, Christopher [1 ]
Taunk, Neil K. [1 ]
Dong, Lei [1 ]
Metz, James M. [1 ]
Li, Taoran [1 ]
Freedman, Gary M. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Perelman Ctr Adv Med, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
IRREGULAR SURFACE COMPENSATOR; FIELD-IN-FIELD; RADIATION; COVERAGE; THERAPY; TISSUE; NODES; MV;
D O I
10.1016/j.adro.2019.05.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Three-dimensional (3D) conformal radiation therapy is the standard technique used for adjuvant breast radiation. We report the clinical use of a novel 6-MV flattening-filter-free O-ring linear accelerator (6X-FFF ORL) for breast cancer that may improve upon 3D conformal radiation therapy with its higher dose rate and faster rotation and leaf speed than traditional C-arm gantries. Methods and Materials: We retrospectively identified consecutive women with breast cancer who underwent surgery followed by radiation therapy to the breast or chest wall on Halcyon (Varian Medical Systems, Palo Alto, CA), a novel 6X-FFF ORL. We report their clinicopathologic information, radiation therapy details, acute toxicities, dose-volume histogram data, couch corrections, and treatment times. Results: Thirty-four women were treated for breast cancer on a 6X-FFF ORL between February 2018 and September 2018. All patients underwent lumpectomy (92%) or mastectomy (8%). Tumors were left sided in 44% and bilateral in 9%, and 9% included comprehensive nodal radiation therapy. Twelve percent of patients were treated prone and 29% with deep-inspiration breath hold. Standard target and normal-tissue constraints were met in nearly all plans. The 3D vector couch correction average was 0.77 +/- 0.05 cm. The mean beam-on time was 2.0 +/- 0.3 minutes, and mean treatment time from start of imaging to beam-off was 4.4 +/- 0.4 minutes. Grade 2 dermatitis, fatigue, and breast pain occurred in 18%, 9%, and 3% of patients, respectively. Conclusions: In this first clinical report of breast radiation therapy with a 6X-FFF ORL, treatment was versatile and fast for complex setups and techniques, with acceptable toxicity and organ-at-risk doses. Thus, a 6X-FFF ORL can increase throughput or reduce length of day compared with a conventional C-arm linear accelerator in departments with a busy breast service. (C) 2019 The Author(s). Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页码:571 / 578
页数:8
相关论文
共 20 条
[1]   Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy [J].
Batumalai, Vikneswary ;
Phan, Penny ;
Choong, Callie ;
Holloway, Lois ;
Delaney, Geoff P. .
JOURNAL OF MEDICAL RADIATION SCIENCES, 2016, 63 (04) :224-231
[2]   Variability of the location of internal mammary vessels and glandular breast tissue in breast cancer patients undergoing routine CT-based treatment planning [J].
Bentel, G ;
Marks, LB ;
Hardenbergh, P ;
Prosnitz, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1017-1025
[3]   Novel Radiotherapy Techniques for Breast Cancer [J].
Bradley, Julie A. ;
Mendenhall, Nancy P. .
ANNUAL REVIEW OF MEDICINE, VOL 69, 2018, 69 :277-288
[4]   The characterization of unflattened photon beams from a 6 MV linear accelerator [J].
Cashmore, Jason .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (07) :1933-1946
[5]   Improvement of dose distribution with irregular surface compensator in whole breast radiotherapy [J].
Hideki, Fujita ;
Nao, Kuwahata ;
Hiroyuki, Hattori ;
Hiroshi, Kinoshita ;
Haruyuki, Fukuda .
JOURNAL OF MEDICAL PHYSICS, 2013, 38 (03) :115-119
[6]   Radiation during deep inspiration allows loco-regional treatment of left breast and axillary-, supraclavicular- and internal mammary lymph nodes without compromising target coverage or dose restrictions to organs at risk [J].
Hjelstuen, Mari H. B. ;
Mjaaland, Ingvil ;
Vikstrom, Johan ;
Dybvik, Kjell Ivar .
ACTA ONCOLOGICA, 2012, 51 (03) :333-344
[7]   Whole Breast Irradiation with Halcyon (TM) 2.0: Workflow and Efficiency of Field-in-Field Treatment with Dynamic Beam Flattening Technique and kV Cone Beam Computed Tomography [J].
Kennedy, Chris ;
Freedman, Gary ;
Taunk, Neil ;
Scheuermann, Ryan ;
Dong, Lei ;
Metz, James M. ;
Li, Taoran .
CUREUS, 2018, 10 (10)
[8]   Dosimetric Comparison of Irregular Surface Compensator and Field-in-Field for Whole Breast Radiotherapy [J].
Kuwahata, Nao ;
Fujita, Hideki ;
Yamanishi, Hideaki ;
Okazaki, Eiichiro ;
Fukuda, Haruyuki .
JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) :79-84
[9]   Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT [J].
Li, Yuting ;
Netherton, Tucker ;
Nitsch, Paige L. ;
Balter, Peter A. ;
Gao, Song ;
Klopp, Ann H. ;
Court, Laurence E. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03) :52-57
[10]   Prospective Assessment of Optimal Individual Position (Prone Versus Supine) for Breast Radiotherapy: Volumetric and Dosimetric Correlations in 100 Patients [J].
Lymberis, Stella C. ;
deWyngaert, John Keith ;
Parhar, Preeti ;
Chhabra, Arpit M. ;
Fenton-Kerimian, Maria ;
Chang, Jengwha ;
Hochman, Tsivia ;
Guth, Amber ;
Roses, Daniel ;
Goldberg, Judith D. ;
Formenti, Silvia C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (04) :902-909