Comparison of Immunochromatographic Strips Using Colloidal Gold, Quantum Dots, and Upconversion Nanoparticles for Visual Detection of Norfloxacin in Milk Samples

被引:24
作者
Hu, Gaoshuang [1 ]
Gao, Shan [1 ]
Han, Xue [1 ]
Yang, Lixin [2 ]
机构
[1] Hebei Univ Sci & Technol, Coll Biosci & Bioengn, Shijiazhuang 050018, Hebei, Peoples R China
[2] Hebei Prov Ctr Dis Control & Prevent, Shijiazhuang 050018, Hebei, Peoples R China
关键词
Norfloxacin; Upconversion nanoparticles; Quantum dots; Colloidal gold; Immunochromatographic strips; Milk; SOLID-PHASE EXTRACTION; RAPID DETECTION; QUANTITATIVE DETECTION; FLUOROQUINOLONES; FLUORESCENCE; ASSAY; CIPROFLOXACIN; IMMUNOASSAY; SENSITIVITY; QUINOLONES;
D O I
10.1007/s12161-020-01725-3
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Colloidal gold, quantum dots (QDs), and upconversion nanoparticles (UCNPs), which were respectively labeled with monoclonal antibody against norfloxacin (NOR), were employed as signal probes to establish three types of immunochromatographic strips, and the strips were evaluated according to their ability to detect NOR in milk samples. The results showed that the visual detection limit of NOR was 2.0 mu g L-1 in the standard solution and 20.0 mu g L-1 in milk samples when using colloidal gold-immunochromatographic strips (ICS). When QD-based fluorescence immunochromatographic strips (FICS) were used, the visual detection limit was 2.0 mu g L-1 in the standard solution and 10.0 mu g L-1 in milk samples. If UCNP-based FICS strips were employed, the visual limit of detection was 0.5 mu g L-1 in the standard solution and 2.5 mu g L-1 in milk samples. Besides, the results from the proposed methods showed high agreement with results yielded by using commercial ELISA kits, indicating the good accuracy of these strips. Compared with colloidal gold-ICS, QDs-FICS showed similar sensitivity in the standard solution and a two-fold higher sensitivity in milk samples. Meanwhile, UCNPs-FICS yielded the highest sensitivity both in standard solution and in milk samples, and they were also more stable in normal laboratory conditions (that is, they could be exposed to regular room light). Additionally, the two fluorescence nanoparticle-based test strips could be built with less antibody and coating antigens and can be cost-effective. In conclusion, the proposed QDs-FICS and UCNPs-FICS could be employed as cost-effective alternative methods for sensitive, rapid, and on-site detection of NOR in milk samples.
引用
收藏
页码:1069 / 1077
页数:9
相关论文
共 40 条
  • [1] A novel electrochemical aptasensor for ultrasensitive detection of fluoroquinolones based on single-stranded DNA-binding protein
    Abnous, Khalil
    Danesh, Noor Mohammad
    Alibolandi, Mona
    Ramezani, Mohammad
    Taghdisi, Seyed Mohammad
    Emrani, Ahmad Sarreshtehdar
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 100 - 106
  • [2] Liquid chromatography-tandem mass spectrometry for rapid and selective simultaneous determination of fluoroquinolones level in human aqueous humor
    Alhusban, Ala A.
    Tarawneh, Ola A.
    Dawabsheh, Sanabel O.
    Alhusban, Ahmad A.
    Abumhareb, Feras W.
    [J]. JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2019, 97 : 36 - 43
  • [3] Chemical tuning for potential antitumor fluoroquinolones
    Anaya-Gonzalez, Cristina
    Soldevila, Sonia
    Garcia-Lainez, Guillermo
    Bosca, Francisco
    Andreu, Inmaculada
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2019, 141 : 150 - 158
  • [4] Electrochemical, theoretical and analytical studies of the electro-oxidation of sulfamerazine and norfloxacin on a glassy carbon electrode
    Canales, Camila
    Ramos, Danilo
    Fierro, Angelica
    Antilen, Monica
    [J]. ELECTROCHIMICA ACTA, 2019, 318 : 847 - 856
  • [5] Direct determination of ciprofloxacin by mass spectrometry after a two-step solid-phase extraction using a molecularly imprinted polymer
    Caro, Ester
    Marce, Rosa M.
    Cormack, Peter A. G.
    Sherrington, David C.
    Borrull, Francesc
    [J]. JOURNAL OF SEPARATION SCIENCE, 2006, 29 (09) : 1230 - 1236
  • [6] Genotypic detection of fluoroquinolone resistance in drug-resistant Mycobacterium tuberculosis at a tertiary care centre in south Coastal Karnataka, India
    Chawla, Kiran
    Kumar, Ajay
    Shenoy, Vishnu Prasad
    Chakrabarty, Sanjiban
    Satyamoorthy, Kapaettu
    [J]. JOURNAL OF GLOBAL ANTIMICROBIAL RESISTANCE, 2018, 13 : 250 - 253
  • [7] Heterologous strategy enhancing the sensitivity of the fluorescence polarization immunoassay of clinafloxacin in goat milk
    Chen, Jiahong
    Shanin, Ilya A.
    Lv, Shuwei
    Wang, Qiang
    Mao, Chuanbin
    Xu, Zhenlin
    Sun, Yuanming
    Wu, Qing
    Eremin, Sergei A.
    Lei, Hongtao
    [J]. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2016, 96 (04) : 1341 - 1346
  • [8] An indirect competitive enzyme-linked immunosorbent assay for determination of norfloxacin in waters using a specific polyclonal antibody
    Cui, Jianlan
    Zhang, Kun
    Huang, Qiuxin
    Yu, Yiyi
    Peng, Xianzhi
    [J]. ANALYTICA CHIMICA ACTA, 2011, 688 (01) : 84 - 89
  • [9] Fluoroquinolones metal complexation and its environmental impacts
    Cuprys, Agnieszka
    Pulicharla, Rama
    Brar, Satinder Kaur
    Drogui, Patrick
    Verma, Mausam
    Surampalli, Rao Y.
    [J]. COORDINATION CHEMISTRY REVIEWS, 2018, 376 : 46 - 61
  • [10] A fluorescent immunochromatographic strip test using Quantum Dots for fumonisins detection
    Di Nardo, F.
    Anfossi, L.
    Giovannoli, C.
    Passini, C.
    Goftman, V. V.
    Goryacheva, I. Y.
    Baggiani, C.
    [J]. TALANTA, 2016, 150 : 463 - 468