Survey on utilization of flattening filter-free photon beams in Japan

被引:1
作者
Kodama, Takumi [1 ]
Yasui, Keisuke [2 ]
Nishioka, Shie [3 ]
Miyaura, Kazunori [4 ]
Takakura, Toru [5 ]
Katayose, Tetsurou [6 ]
Nakamura, Mitsuhiro [7 ]
机构
[1] Saitama Canc Ctr, Dept Radiat Oncol, 780 Ooazakomuro, Ina, Saitama 3620806, Japan
[2] Fujita Hlth Univ, Fac Radiol Technol, Sch Hlth Sci, 1-98 Dengakugakubo,Kutsukake Cho, Toyoake, Aichi 4701192, Japan
[3] Natl Canc Ctr, Dept Med Phys, Chuo Ku, 5-1-1 Tsukiji, Tokyo 1040045, Japan
[4] Showa Univ, Grad Sch Hlth Sci, Shinagawa Ku, 1-5-8 Hatanodai, Tokyo 1428666, Japan
[5] Uji Tokushukai Med Ctr, Dept Radiat Therapy, 145 Ishibashi,Makichima Cho, Uji, Kyoto 6110041, Japan
[6] Chiba Canc Ctr, Dept Radiat Oncol, Chuo Ku, 666-2 Nitona Cho, Chiba 2608717, Japan
[7] Kyoto Univ, Grad Sch Med, Dept Informat Technol & Med Engn, Human Hlth Sci,Sakyo Ku, 53 Shogoin Kawahara Cho, Kyoto 6068507, Japan
关键词
survey; flattening filter-free (FFF) beams; utilization for treatment; measurement protocols; ION RECOMBINATION CORRECTION; MODULATED ARC THERAPY; STOPPING-POWER RATIOS; HIGH-DOSE-RATE; IONIZATION CHAMBERS; STEREOTACTIC RADIOTHERAPY; QUALITY-ASSURANCE; FREE ACCELERATORS; P-ION; CANCER;
D O I
10.1093/jrr/rrab042
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To understand the current state of flattening filter-free (FFF) beam implementation in C-arm linear accelerators (LINAC) in Japan, the quality assurance (QA)/quality control (QC) 2018-2019 Committee of the Japan Society of Medical Physics (JSMP) conducted a 37-question survey, designed to investigate facility information and specifications regarding FFF beam adoption and usage. The survey comprised six sections: facility information, devices, clinical usage, standard calibration protocols, modeling for treatment planning (TPS) systems and commissioning and QA/QC. A web-based questionnaire was developed. Responses were collected between 18 June and 18 September 2019. Of the 846 institutions implementing external radiotherapy, 323 replied. Of these institutions, 92 had adopted FFF beams and 66 had treated patients using them. FFF beams were used in stereotactic radiation therapy (SRT) for almost all disease sites, especially for the lungs using 6 MV and liver using 10 MV in 51 and 32 institutions, respectively. The number of institutions using FFF beams for treatment increased yearly, from eight before 2015 to 60 in 2018. Farmer-type ionization chambers were used as the standard calibration protocol in 66 (72%) institutions. In 73 (80%) institutions, the beam-quality conversion factor for FFF beams was calculated from TPR20,10, via the same protocol used for beams with flattening filter (WFF). Commissioning, periodic QA and patient-specific QA for FFF beams also followed the procedures used for WFF beams. FFF beams were primarily used in high-volume centers for SRT. Inmost institutions, measurement and QA was conducted via the procedures used for WFF beams.
引用
收藏
页码:726 / 734
页数:9
相关论文
共 39 条
[1]  
Abd El-Hafez AI, 2011, J AM SCI, V7, P206
[2]   Modalities and techniques used for stereotactic radiotherapy, intensity-modulated radiotherapy, and image-guided radiotherapy: A 2018 survey by the Japan Society of Medical Physics [J].
Akino, Yuichi ;
Tohyama, Naoki ;
Akita, Kazuhiko ;
Ishikawa, Masayori ;
Kawamorita, Ryu ;
Kurooka, Masahiko ;
Sumida, Iori ;
Nakaguchi, Yuji ;
Miyaura, Kazunori ;
Nakamura, Mitsuhiro .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 :182-187
[3]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[4]   Prediction of stopping-power ratios in flattening-filter free beams [J].
Ceberg, Crister ;
Johnsson, Stefan ;
Lind, Marten ;
Knoos, Tommy .
MEDICAL PHYSICS, 2010, 37 (03) :1164-1168
[5]   On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy [J].
Clivio, Alessandro ;
Belosi, Maria Francesca ;
Cozzi, Luca ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Bolard, Gregory ;
Fenoglietto, Pascal ;
Krauss, Harald ;
Fogliata, Antonella .
MEDICAL PHYSICS, 2014, 41 (02)
[6]   Pion effects in flattening filter-free radiation beams [J].
Corns, Robert A. ;
Huang, Vicky W. ;
Thomas, Steven D. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06) :376-385
[7]   Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams [J].
Dalaryd, Marten ;
Knoos, Tommy ;
Ceberg, Crister .
MEDICAL PHYSICS, 2014, 41 (11)
[8]   Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy [J].
Fogliata, A. ;
Garcia, R. ;
Knoos, T. ;
Nicolini, G. ;
Clivio, A. ;
Vanetti, E. ;
Khamphan, C. ;
Cozzi, L. .
MEDICAL PHYSICS, 2012, 39 (10) :6455-6464
[9]   Delivery time comparison for intensity-modulated radiation therapy with/without flattening filter: a planning study [J].
Fu, WH ;
Dai, JR ;
Hu, YM ;
Han, DS ;
Song, YX .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08) :1535-1547
[10]   A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer [J].
Gasic, Daniel ;
Ohlhues, Lars ;
Brodin, N. Patrik ;
Fog, Lotte S. ;
Pommer, Tobias ;
Bangsgaard, Jens P. ;
Rosenschold, Per Munck A. F. .