Kinetic visual acuity, stereopsis, and ocular deviation with an implantable collamer lens

被引:4
作者
Kato, Sayaka [1 ]
Shimizu, Kimiya [1 ]
Igarashi, Akihito [1 ]
Kawamorita, Takushi [2 ]
机构
[1] Sanno Hosp, Eye Ctr, Minato Ku, 8-10-16 Akasaka, Tokyo 1070052, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Dept Orthopt & Visual Sci, Minami Ku, Sagamihara, Kanagawa, Japan
关键词
IN-SITU KERATOMILEUSIS; INTRAOCULAR-LENS; REFRACTIVE SURGERY; MODERATE;
D O I
10.1016/j.jcrs.2019.08.009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare kinetic visual acuity, stereopsis, ocular deviation, and fusion amplitude before and after implantable collamer lens (ICL) surgery. Setting: Sanno Hospital. Design: Retrospective analysis. Methods: The charts of adult patients who underwent implantation of an ICL with a central aquaport (V4c) for emmetropia were reviewed. The mean preoperative spherical equivalent and subjective astigmatism were -7.87 diopters (D) +/- 3.13 (SD) and -0.75 +/- 0.78 D, respectively. All measurements were obtained with full refraction before surgery and without spectacle correction after surgery. The kinetic visual acuity was measured with the AS4D device. Stereopsis and ocular deviation were measured with the Titmus Stereotest and an alternate prism cover test, respectively. Fusion amplitude was determined from breakpoints measured using a prism. Results: The study comprised 29 adult patients (58 eyes). One month postoperatively, the mean safety and efficacy indices were 1.13 +/- 0.20 and 0.96 +/- 0.25, respectively, and 57 eyes (98.7%) were within +/- 0.5 D of the target correction. The mean kinetic visual acuity (logarithm of the minimum angle of resolution) was 0.30 +/- 0.21 preoperatively and 0.20 +/- 0.15 (Snellen 20/40 versus 20/32) postoperatively and the mean stereopsis (seconds of arc), 48.5 +/- 1.6 versus 41.5 +/- 1.1; both improved significantly (P < .001 and P = .012, respectively). The mean distance ocular deviation (-4.0 +/- 3.8 prism diopters [Delta] versus 2.8 +/- 3.6 Delta; P =.002) and near ocular deviation (-6.5 +/- 6.7 A versus 5.4 +/- 6.9 Delta; P =.04) decreased significantly. The fusion amplitude increased for near vision only. Conclusions: ICL implantation improved kinetic visual acuity and stereopsis, decreased ocular deviation, and increased near fusion amplitude. (C) 2019 ASCRS and ESCRS.
引用
收藏
页码:1777 / 1781
页数:5
相关论文
共 16 条
  • [1] Phakic posterior chamber intraocular lens for the correction of anisometropia and treatment of amblyopia
    BenEzra, D
    Cohen, E
    Karshai, I
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (03) : 292 - 296
  • [2] Dougherty PJ, 2017, CLIN OPHTHALMOL, V11, P273, DOI 10.2147/OPTH.S120427
  • [3] Effect of refractive surgery on binocular vision and ocular alignment in patients with manifest or intermittent strabismus
    Godts, D.
    Trau, R.
    Tassignon, M-J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (11) : 1410 - 1413
  • [4] Changes in fusional vergence amplitudes after laser refractive surgery for moderate myopia
    Han, Jinu
    Hong, Samin
    Lee, Seungjae
    Kim, Jin Kook
    Lee, Hyung Keun
    Han, Sueng-Han
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10) : 1670 - 1675
  • [5] Eight-Year Follow-up of Posterior Chamber Phakic Intraocular Lens Implantation for Moderate to High Myopia
    Igarashi, Akihito
    Shimizu, Kimiya
    Kamiya, Kazutaka
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (03) : 532 - 539
  • [6] Visual Performance after Implantable Collamer Lens Implantation and Wavefront-Guided Laser In Situ Keratomileusis for High Myopia
    Igarashi, Akihito
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Komatsu, Mari
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (01) : 164 - 170
  • [7] Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation
    Iijima, Ayaka
    Shimizu, Kimiya
    Yamagishi, Mayumi
    Kobashi, Hidenaga
    Igarashi, Akihito
    Kamiya, Kazutaka
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (08) : E716 - E720
  • [8] Effect of Myopic Defocus on Visual Acuity after Phakic Intraocular Lens Implantation and Wavefront-guided Laser in Situ Keratomileusis
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kawamorita, Takushi
    [J]. SCIENTIFIC REPORTS, 2015, 5
  • [9] Comparison of Optical Quality and Intraocular Scattering after Posterior Chamber Phakic Intraocular Lens with and without a Central Hole (Hole ICL and Conventional ICL) Implantation Using the Double-Pass Instrument
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Saito, Aya
    Igarashi, Akihito
    Kobashi, Hidenaga
    [J]. PLOS ONE, 2013, 8 (06):
  • [10] Visual Performance After Posterior Chamber Phakic Intraocular Lens Implantation and Wayefront-Guided Laser In Situ Keratomileusis for Low to Moderate Myopia
    Kamiya, Kazutaka
    Igarashi, Akihito
    Shimizu, Kimiya
    Matsumura, Kazuhiro
    Komatsu, Mari
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (06) : 1178 - 1186