Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis

被引:371
|
作者
Friedrich-Rust, M. [1 ]
Nierhoff, J. [2 ]
Lupsor, M. [3 ]
Sporea, I. [4 ]
Fierbinteanu-Braticevici, C. [5 ]
Strobel, D. [6 ]
Takahashi, H. [7 ]
Yoneda, M. [8 ]
Suda, T. [9 ]
Zeuzem, S. [1 ]
Herrmann, E. [2 ]
机构
[1] Goethe Univ Frankfurt, Dept Internal Med 1, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Inst Biostat & Math Modeling, Fac Med, D-60590 Frankfurt, Germany
[3] Univ Med & Pharm, Dept Ultrasonog, Cluj Napoca, Romania
[4] Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisoara, Romania
[5] Univ Hosp, Med Clin 2, Bucharest, Romania
[6] Univ Erlangen Nurnberg, Dept Internal Med 1, Erlangen, Germany
[7] Saga Med Sch, Dept Internal Med, Saga, Japan
[8] Yokohama City Univ Med, Div Gastroenterol, Yokohama, Kanagawa, Japan
[9] Niigata Univ, Dept Gastroenterol & Hepatol, Niigata, Japan
关键词
ARFI; elastography; fibrosis staging; liver biopsy; liver stiffness; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; SAMPLING VARIABILITY; ARFI TECHNOLOGY; IN-VIVO; FIBROTEST; DISEASE; BIOPSY; ELASTICITY; DIAGNOSIS;
D O I
10.1111/j.1365-2893.2011.01537.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Acoustic Radiation Force Impulse (ARFI) imaging is a novel ultrasound-based elastography method that is integrated in a conventional ultrasound machine enabling the exact localization of measurement site. It might present an alternative method to transient elastography for the noninvasive assessment of liver fibrosis. At present, studies with small patient population have shown promising results. A systematic review and meta-analysis of pooled patient data were performed to evaluate the overall performance of ARFI for the staging of liver fibrosis. Literature databases were searched up to 10/2010. The authors of the original publication were contacted, and the original patient data were requested. A meta-analysis was performed using a random effect meta-analytic method for diagnostic tests. In addition, available data comparing ARFI with FibroScan with the DeLong test were evaluated. Literature search yielded nine full-paper publications evaluating ARFI while using liver biopsy as reference method. Original patient data were available from eight studies including 518 patients. The mean diagnostic accuracy of ARFI expressed as areas under ROC curves (AUROC) was 0.87 for the diagnosis of significant fibrosis (F = 2), 0.91 for the diagnosis of severe fibrosis (F = 3), and 0.93 for the diagnosis of cirrhosis. ARFI can be performed with good diagnostic accuracy for the noninvasive staging of liver fibrosis.
引用
收藏
页码:E212 / E219
页数:8
相关论文
共 50 条
  • [31] Reproducibility of Shear Wave Velocity Measurements by Acoustic Radiation Force Impulse Imaging of the Liver A Study in Healthy Volunteers
    Guzman-Aroca, Florentina
    Reus, Manuel
    Berna-Serna, Juan D.
    Serrano, Laura
    Serrano, Cristina
    Gilabert, Amparo
    Cepero, Angela
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (07) : 975 - 979
  • [32] Acoustic Radiation Force Impulse Imaging in Paediatric Patients: Normal Liver Values
    Matos, Hugo
    Trindade, Ana
    Noruegas, Maria J.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2014, 59 (06) : 684 - 688
  • [33] Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis
    Carmen Fierbinteanu-Braticevici
    Dan Andronescu
    Radu Usvat
    Dragos Cretoiu
    Cristian Baicus
    Gabriela Marinoschi
    World Journal of Gastroenterology, 2009, 15 (44) : 5525 - 5532
  • [34] Acoustic radiation force impulse elastography and liver fibrosis risk scores in severe obesity
    da Silva Junior, Roberto Gomes
    Queiroz de Miranda, Maria Luiza
    de Araujo Caldeira Brant, Paulo Eugenio
    Schulz, Perla Oliveira
    Araujo Nascimento, Maria de Fatima
    Schmillevitch, Joel
    Vieira, Andrea
    de Freitas Junior, Wilson Rodrigues
    Szutan, Luiz Arnaldo
    ARCHIVES OF ENDOCRINOLOGY METABOLISM, 2021, 65 (06): : 730 - 738
  • [35] Clinical utility of acoustic radiation force impulse imaging for identification of malignant liver lesions: a meta-analysis
    Ying, Li
    Lin, Xiao
    Xie, Zuo-Liu
    Tang, Fei-Yun
    Hu, Yuan-Ping
    Shi, Ke-Qing
    EUROPEAN RADIOLOGY, 2012, 22 (12) : 2798 - 2805
  • [36] Acoustic radiation force impulse of the liver
    D'Onofrio, Mirko
    Crosara, Stefano
    De Robertis, Riccardo
    Canestrini, Stefano
    Demozzi, Emanuele
    Gallotti, Anna
    Mucelli, Roberto Pozzi
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (30) : 4841 - 4849
  • [37] Comparison of Transient Elastography and Acoustic Radiation Force Impulse for Non-Invasive Staging of Liver Fibrosis in Patients With Chronic Hepatitis C
    Rizzo, L.
    Calvaruso, Vincenza
    Cacopardo, B.
    Alessi, N.
    Attanasio, M.
    Petta, S.
    Fatuzzo, F.
    Montineri, A.
    Mazzola, A.
    L'abbate, L.
    Nunnari, G.
    Bronte, F.
    Di Marco, V.
    Craxi, A.
    Camma, C.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 (12) : 2112 - 2120
  • [38] Assessment of liver fibrosis with acoustic radiation force impulse imaging versus liver histology in patients with chronic hepatitis C: a pilot study
    Kohla, Mohamed A. S.
    Abbasy, Mohamed
    Abozeid, Mai
    El-Abd, Osama
    Ezzat, Sameera
    Kohla, Samah
    Abdel-Rahman, Mohamed
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2017, 29 (08) : 951 - 955
  • [39] Technical Performance of Acoustic Radiation Force Impulse Imaging for Measuring Renal Parenchymal Stiffness A Systematic Review and Meta-Analysis
    Hwang, Jisun
    Kim, Hae Won
    Kim, Pyeong Hwa
    Suh, Chong Hyun
    Yoon, Hee Mang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (12) : 2639 - 2653
  • [40] Diagnostic value of acoustic radiation force impulse elastography and transient elastography for fibrosis staging in chronic hepatitis C: A meta-analysis
    Lubis, Fadhyl Zuhry
    Okvaria, Ristari
    Habib, Moh
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 : 32 - 32