Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis

被引:371
|
作者
Friedrich-Rust, M. [1 ]
Nierhoff, J. [2 ]
Lupsor, M. [3 ]
Sporea, I. [4 ]
Fierbinteanu-Braticevici, C. [5 ]
Strobel, D. [6 ]
Takahashi, H. [7 ]
Yoneda, M. [8 ]
Suda, T. [9 ]
Zeuzem, S. [1 ]
Herrmann, E. [2 ]
机构
[1] Goethe Univ Frankfurt, Dept Internal Med 1, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Inst Biostat & Math Modeling, Fac Med, D-60590 Frankfurt, Germany
[3] Univ Med & Pharm, Dept Ultrasonog, Cluj Napoca, Romania
[4] Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisoara, Romania
[5] Univ Hosp, Med Clin 2, Bucharest, Romania
[6] Univ Erlangen Nurnberg, Dept Internal Med 1, Erlangen, Germany
[7] Saga Med Sch, Dept Internal Med, Saga, Japan
[8] Yokohama City Univ Med, Div Gastroenterol, Yokohama, Kanagawa, Japan
[9] Niigata Univ, Dept Gastroenterol & Hepatol, Niigata, Japan
关键词
ARFI; elastography; fibrosis staging; liver biopsy; liver stiffness; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; SAMPLING VARIABILITY; ARFI TECHNOLOGY; IN-VIVO; FIBROTEST; DISEASE; BIOPSY; ELASTICITY; DIAGNOSIS;
D O I
10.1111/j.1365-2893.2011.01537.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Acoustic Radiation Force Impulse (ARFI) imaging is a novel ultrasound-based elastography method that is integrated in a conventional ultrasound machine enabling the exact localization of measurement site. It might present an alternative method to transient elastography for the noninvasive assessment of liver fibrosis. At present, studies with small patient population have shown promising results. A systematic review and meta-analysis of pooled patient data were performed to evaluate the overall performance of ARFI for the staging of liver fibrosis. Literature databases were searched up to 10/2010. The authors of the original publication were contacted, and the original patient data were requested. A meta-analysis was performed using a random effect meta-analytic method for diagnostic tests. In addition, available data comparing ARFI with FibroScan with the DeLong test were evaluated. Literature search yielded nine full-paper publications evaluating ARFI while using liver biopsy as reference method. Original patient data were available from eight studies including 518 patients. The mean diagnostic accuracy of ARFI expressed as areas under ROC curves (AUROC) was 0.87 for the diagnosis of significant fibrosis (F = 2), 0.91 for the diagnosis of severe fibrosis (F = 3), and 0.93 for the diagnosis of cirrhosis. ARFI can be performed with good diagnostic accuracy for the noninvasive staging of liver fibrosis.
引用
收藏
页码:E212 / E219
页数:8
相关论文
共 50 条
  • [21] Acoustic Radiation Force Impulse Imaging: a New Technology for the Noninvasive Assessment of Liver Fibrosis?
    Castera, Laurent
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2009, 18 (04) : 411 - 412
  • [22] Diagnostic performance of acoustic radiation force impulse for acute pancreatitis: A meta-analysis
    Wang, Wen Jie
    Zhang, Li Wei
    Feng, Shun Yi
    MEDICINE, 2024, 103 (19) : E38035
  • [23] Diagnostic Accuracy of SuperSonic Shear Imaging for Staging of Liver Fibrosis A Meta-analysis
    Feng, Jin-Chun
    Li, Jun
    Wu, Xiang-Wei
    Peng, Xin-Yu
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (02) : 329 - 339
  • [24] Serial changes of liver stiffness measured by acoustic radiation force impulse imaging in acute liver failure: A case report
    Kuroda, Hidekatsu
    Takikawa, Yasuhiro
    Onodera, Mio
    Kakisaka, Keisuke
    Yoshida, Yuichi
    Kataoka, Koujiro
    Sawara, Kei
    Miyamoto, Yasuhiro
    Oikawa, Kanta
    Endo, Ryujin
    Suzuki, Kazuyuki
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 99 - 104
  • [25] Acoustic Radiation Force Impulse (ARFI) for Fibrosis Staging in Patients with Autoimmune Hepatitis
    Efe, Cumali
    Gungoren, Merve Sibel
    Ozaslan, Ersan
    Akbiyik, Filiz
    Kav, Taylan
    HEPATO-GASTROENTEROLOGY, 2015, 62 (139) : 670 - 672
  • [26] Performance of Real-Time Elastography for the Staging of Hepatic Fibrosis: A Meta-Analysis
    Hong, Huisuo
    Li, Jia
    Jin, Yin
    Li, Qiao
    Li, Weimin
    Wu, Jiansheng
    Huang, Zhiming
    PLOS ONE, 2014, 9 (12):
  • [27] Measurement of Liver Elasticity with Acoustic Radiation Force Impulse (ARFI) Technology: An Alternative Noninvasive Method for Staging Liver Fibrosis in Viral Hepatitis
    Goertz, R. S.
    Zopf, Y.
    Jugl, V.
    Heide, R.
    Janson, C.
    Strobel, D.
    Bernatik, T.
    Haendl, T.
    ULTRASCHALL IN DER MEDIZIN, 2010, 31 (02): : 151 - 155
  • [28] ASSESSMENT OF LIVER FIBROSIS WITH 2-D SHEAR WAVE ELASTOGRAPHY IN COMPARISON TO TRANSIENT ELASTOGRAPHY AND ACOUSTIC RADIATION FORCE IMPULSE IMAGING IN PATIENTS WITH CHRONIC LIVER DISEASE
    Gerber, Ludmila
    Kasper, Daniela
    Fitting, Daniel
    Knop, Viola
    Vermehren, Annika
    Sprinzl, Kathrin
    Hansmann, Martin L.
    Herrmann, Eva
    Bojunga, Joerg
    Albert, Joerg
    Sarrazin, Christoph
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (09) : 2350 - 2359
  • [29] Acoustic Radiation Force Impulse Imaging for Assessing Liver Fibrosis Preoperatively in Infants With Biliary Atresia
    Gao, Fen
    Chen, Ya-Qing
    Fang, Jing
    Gu, Sheng-Li
    Li, Luan
    Wang, Xiao-Ying
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (08) : 1571 - 1578
  • [30] Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography
    Friedrich-Rust, Mireen
    Wunder, Katrin
    Kriener, Susanne
    Sotoudeh, Fariba
    Richter, Swantje
    Bojunga, Joerg
    Herrmann, Eva
    Poynard, Thierry
    Dietrich, Christoph F.
    Vermehren, Johannes
    Zeuzem, Stefan
    Sarrazin, Christoph
    RADIOLOGY, 2009, 252 (02) : 595 - 604