Trans-venous lead removal without the use of extraction sheaths, results of >250 removal procedures

被引:20
作者
de Bie, Mihaly K. [1 ]
Fouad, Doaa A. [2 ]
Borleffs, C. Jan Willem [1 ]
van Rees, Johannes B. [1 ]
Thijssen, Joep [1 ]
Trines, Serge A. [1 ]
Bootsma, Marianne [1 ]
Schalij, Martin J. [1 ]
van Erven, Lieselot [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
[2] Aissut Univ Hosp, Dept Cardiol, Assiut, Egypt
来源
EUROPACE | 2012年 / 14卷 / 01期
关键词
Lead extraction; Lead removal; Extraction sheaths; Complications; Infection; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; SINGLE-CENTER; LASER SHEATH; PACEMAKER; EXPERIENCE; SAFETY; FAILURE; SUCCESS; TRIAL;
D O I
10.1093/europace/eur269
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The number of implanted cardiac rhythm devices has rapidly increased in the past decade. Subsequently, the need for lead extraction has also increased. Several techniques of lead removal have been documented from manual traction of the lead to lead extraction assisted with mechanical or laser sheaths. The goal of this study was to review our experience with lead removal using manual traction without the assistance of extraction sheaths. Methods and results In the Leiden University Medical Center all leads are removed using manual traction without the assistance of extraction sheaths. We have retrospectively reviewed all lead removal procedures performed between 2000 and 2009. Procedures were reviewed for indication, success, complication rates, and mortality. In total, 279 lead removal procedures were included. During these procedures 445 leads were removed. Time since lead implantation: 4.2 +/- 4.7 years. During extraction 53(11.9%) leads fractured, of which > 50% could still be completely removed using a femoral approach. A longer implantation duration [odds ratio (OR) 1.16 per year, 95% confidence interval (CI) 1.09-1.23] and passive fixation (OR 2.52, 95% CI 1.17-5.45) significantly associated with the chance of lead fracture during lead removal. Clinical success, using the primary approach of manual traction from the pectoral area, was obtained in 228 (84.8%) procedures. Major complications occurred in 2(0.7%) and minor in 13(4.7%) procedures. One patient died within 24 h after the procedure due to septic shock. There was no further mortality within the first month after the procedure. Conclusion Lead removal using manual traction, without the assistance of lead extraction sheaths, is clinically successful in similar to 85% of the lead extraction procedures. Concomitant morbidity and mortality are low. The highest clinical success (similar to 95%) was observed in patients with leads implanted less than 2.6 years.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 20 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]   Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads [J].
Bongiorni, Maria Grazia ;
Soldati, Ezio ;
Zucchelli, Giulio ;
Di Cori, Andrea ;
Segreti, Luca ;
De Lucia, Raffaele ;
Solarino, Gianluca ;
Balbarini, Alberto ;
Marzilli, Mario ;
Mariani, Mario .
EUROPEAN HEART JOURNAL, 2008, 29 (23) :2886-2893
[3]   Clinical study of the laser sheath for lead extraction: The total experience in the United States [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Reiser, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (05) :804-808
[4]   Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996 [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Turk, KT ;
Reeves, R ;
Young, R ;
Crevey, B ;
Kutalek, SP ;
Freedman, R ;
Friedman, R ;
Trantham, J ;
Watts, M ;
Schutzman, J ;
Oren, J ;
Wilson, J ;
Gold, F ;
Fearnot, NE ;
Van Zandt, HJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09) :1348-1357
[5]   Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators [J].
Chamis, AL ;
Peterson, GE ;
Cabell, CH ;
Corey, GR ;
Sorrentino, RA ;
Greenfield, RA ;
Ryan, T ;
Reller, LB ;
Fowler, VG .
CIRCULATION, 2001, 104 (09) :1029-1033
[6]   Implantable cardioverter-defibrillators - Expanding indications and technologies [J].
Goldberger, Z ;
Lampert, R .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (07) :809-818
[7]   Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction [J].
Hauser, Robert G. ;
Katsiyiannis, William T. ;
Gornick, Charles C. ;
Almquist, Adrian K. ;
Kallinen, Linda M. .
EUROPACE, 2010, 12 (03) :395-401
[8]   Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure [J].
Hauser, Robert G. ;
Hayes, David L. .
HEART RHYTHM, 2009, 6 (05) :605-610
[9]   Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications [J].
Jones, Samuel O. ;
Eckart, Robert E. ;
Albert, Christine M. ;
Epstein, Laurence M. .
HEART RHYTHM, 2008, 5 (04) :520-525
[10]   A single-centre experience of over one thousand lead extractions [J].
Kennergren, Charles ;
Bjurman, Christian ;
Wiklund, Roger ;
Gabel, Jakob .
EUROPACE, 2009, 11 (05) :612-617