Mechanical properties, chloride resistance and microstructure of Portland fly ash cement concrete containing high volume bagasse ash

被引:77
作者
Chindaprasirt, Prinya [1 ,2 ]
Kroehong, Wunchock [3 ]
Damrongwiriyanupap, Nattapong [4 ]
Suriyo, Wuthisak [3 ]
Jaturapitakkul, Chai [5 ]
机构
[1] Khon Kaen Univ, Fac Engn, Dept Civil Engn, Sustainable Infrastruct Res & Dev Ctr, Khon Kaen 40002, Thailand
[2] Royal Soc Thailand, Acad Sci, Bangkok 10300, Thailand
[3] Rajamangala Univ Technol Tawan Ok, Dept Civil Engn, Fac Engn & Architecture, Uthenthawai Campus, Bangkok, Thailand
[4] Univ Phayao, Sch Engn, Civil Engn Program, Phayao, Thailand
[5] King Mongkuts Univ Technol Thonburi, Dept Civil Engn, Fac Engn, Bangkok, Thailand
关键词
High volume; Ternary blend; Chloride penetration; Accelerated corrosion; Eco friendly concrete; OIL FUEL ASH; RICE HUSK ASH; DURABILITY PROPERTIES; WATER PERMEABILITY; TERNARY BLEND; STRENGTH; PERFORMANCE; TEMPERATURE; CORROSION; BINDING;
D O I
10.1016/j.jobe.2020.101415
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the mechanical properties, chloride resistance and microstructure of Portland fly ash cement concrete containing high volume bagasse ash (BA) were studied. Both binary and tertiary blended cements were studied and compared. For binary blend, ordinary Portland cement (OPC) was replaced with BA at 50%, 60%, and 70% by binder weight. In the ternary blend, OPC was replaced with 50% and 60% BA and 10% and 20% FA by weight of binder. A water to binder ratio of 0.40 was used and the workability of fresh concrete was maintained by adding a superplasticizer. The compressive strength, splitting tensile, chloride resistance, corrosion resistance of reinforced steel, porosity and scanning electron microscopy of concrete were investigated. The results showed that for the binary system, the incorporation of high volume BA increased the amount of superplasticzer to maintain the workability and the compressive strengths at 28 days was lower than that of the control concrete. However, the resistance to chloride penetration of high volume BA concrete increased with increasing BA. The critical pore size of high volume BA concrete was lower than that of control concrete. the incorporation of high volumes BA reduced the pore size of the matrix by reducing the coarser pores to finer medium capillary pores. In addition, the high volume BA concretes showed significant increase in the 90-day compressive strength from the pozzolanic reaction. For the ternary blend, the incorporation of FA into the system helped the workability of the mixes. The results also indicated that the ternary blend mixture showed that the mix with 50%BA and 20%FA was the best considering the strength, durability and cost. The use of both BA and FA resulted in concretes with good resistance to chloride permeability, which led to a beneficial improvement of corrosion resistance. The results confirmed that the use of high volume BA-FA concrete as an eco-friendly construction material resulted in improved durability and cost saving.
引用
收藏
页数:11
相关论文
共 67 条
[1]   Production of low cost self compacting concrete using bagasse ash [J].
Akram, Tayyeb ;
Memon, Shazim Ali ;
Obaid, Humayun .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (02) :703-712
[2]   High volume fly ash concrete: The practical impact of using superabundant dose of high range water reducer [J].
Alaka, Hafiz A. ;
Oyedele, Lukumon O. .
JOURNAL OF BUILDING ENGINEERING, 2016, 8 :81-90
[3]   Chloride-induced reinforcing steel corrosion in ternary concretes containing fly ash and untreated sugarcane bagasse ash [J].
Alberto Franco-Lujan, Victor ;
Antonio Maldonado-Garcia, Marco ;
Manuel Mendoza-Rangel, Jose ;
Montes-Garcia, Pedro .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 198 :608-618
[4]   Assessment on engineering properties and CO2 emissions of recycled aggregate concrete incorporating waste products as supplements to Portland cement [J].
Alnahhal, Mohammed Fouad ;
Alengaram, U. Johnson ;
Jumaat, Mohd Zamin ;
Abutaha, Fuad ;
Alqedra, Mamoun A. ;
Nayaka, Ramappa Ramesh .
JOURNAL OF CLEANER PRODUCTION, 2018, 203 :822-835
[5]  
AMERICAN SOCIETY FOR TESTING AND MATERIALS, 2009, ASTM C 1202: Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration
[6]  
[Anonymous], 2011, 31811 ACI COMM ISO
[7]  
[Anonymous], 2010, ASTM C78-09, DOI [10.1520/C0078-09, DOI 10.1520/C0078-09, 10.1520/C0078, DOI 10.1520/C0078]
[8]  
[Anonymous], 2017, ANN BOOK ASTM STAND
[9]  
[Anonymous], 1989, 356 NT
[10]  
[Anonymous], 2001, ASTM Standards, V4, P310, DOI DOI 10.1520/C0618-02