Flow and dispersion in coupled outdoor and indoor environments: Issue of Reynolds number independence

被引:33
作者
Dai, Yuwei [1 ]
Mak, Cheuk Ming [1 ]
Ai, Zhengtao [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Peoples R China
[2] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, Lyngby, Denmark
关键词
Reynolds number independence criteria; Coupled outdoor and indoor environment; Natural ventilation; Pollutant dispersion; CFD simulation; LARGE-EDDY SIMULATION; INDUCED AIR-FLOW; POLLUTANT DISPERSION; AIRBORNE TRANSMISSION; INTERUNIT DISPERSION; NATURAL VENTILATION; CFD SIMULATIONS; RE-INDEPENDENCE; TURBULENT-FLOW; WIND;
D O I
10.1016/j.buildenv.2019.01.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Reynolds number (Re) independence criteria for flow and dispersion around purely outdoor environments has been examined in many previous studies, but little attention has been paid to the coupled outdoor and indoor environments. This study investigated the Re independence criteria of flow and dispersion in coupled outdoor and indoor environments using Computational Fluid Dynamics (CFD) with Large Eddy Simulation (LES) model. Two geometrical arrangements were considered, namely an isolated multi-story building, and an array of multi-story buildings. Four parameters including the non-dimensional air velocity, pollutant concentration, ventilation rate, and re-entry ratio were used to assess the Re independence criteria. The tracer gas decay method was used to predict the ventilation rate and to quantify the re-entry ratio for each room. Using the quantitative indicator, the deviation rate (DR), of the non-dimensional velocity below 5%, two sets of critical values were proposed: Re-H based on the building height equal to 4.8 x 10(4) for the outdoor environment, and Re-w based on the opening height equal to 1.4 x 10(4) for the indoor environment. The concentration field was more difficult to meet the Re-independent requirement. Using the DR of the non-dimensional concentration below 5%, the critical values were Re-H = 7.9 x 10(4) and Re-w = 3.0 x 10(4). If the DR was enlarged to 10%, the Re-H and Re-w criteria for the concentration field were the same as the velocity fields. For the non-dimensional ventilation rate and re-entry ratio, the critical value for the Re independence was Re-w = 1.4 X 10(4) for both the isolated buildings and the building arrays.
引用
收藏
页码:119 / 134
页数:16
相关论文
共 44 条
[1]  
A. Handbook, 2009, ASHRAE HDB FUND
[2]   Large eddy simulation of wind-induced interunit dispersion around multistory buildings [J].
Ai, Z. T. ;
Mak, C. M. .
INDOOR AIR, 2016, 26 (02) :259-273
[3]   Large-eddy Simulation of flow and dispersion around an isolated building: Analysis of influencing factors [J].
Ai, Z. T. ;
Mak, C. M. .
COMPUTERS & FLUIDS, 2015, 118 :89-100
[4]   Potential use of reduced-scale models in CFD simulations to save numerical resources: Theoretical analysis and case study of flow around an isolated building [J].
Ai, Z. T. ;
Mak, C. M. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2014, 134 :25-29
[5]   Modeling of coupled urban wind flow and indoor air flow on a high-density near-wall mesh: Sensitivity analyses and case study for single-sided ventilation [J].
Ai, Z. T. ;
Mak, C. M. .
ENVIRONMENTAL MODELLING & SOFTWARE, 2014, 60 :57-68
[6]   Analysis of fluctuating characteristics of wind-induced airflow through a single opening using LES modeling and the tracer gas technique [J].
Ai, Z. T. ;
Mak, C. M. .
BUILDING AND ENVIRONMENT, 2014, 80 :249-258
[7]   A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions [J].
Ai, Z. T. ;
Mak, C. M. .
ATMOSPHERIC ENVIRONMENT, 2014, 88 :1-13
[8]   Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings [J].
Ai, Z. T. ;
Mak, C. M. ;
Niu, J. L. .
INDOOR AIR, 2013, 23 (05) :417-429
[9]  
Alessio S., 1983, II NUOVO CIMENTO C, V6, P401
[10]  
[Anonymous], 2010, FLUENT 13 0 THEOR GU